Operation
(see page 66)
Flow diagram
(see page 64)
Shower outlet 1B
Tub outlet
Dimensions
(see page 64)
Spare parts
(see page 67)
Cleaning
see enclosed brochure
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Filters are dirty (#96922000)
-
Clean filter in front of the mixer
and on the MTC-thermo cartridge
(#96922000)
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Shower or spout dripping
-
Flow limiter in handshower isn’t
removed
-
Clean or exchange shut-off unit
Instantaneous heater didn't work with
thermostat
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Assembly see page 60
Test certificate
(see page 68)
English
7
Содержание AXOR Citterio E 34435000
Страница 60: ...60 Montage 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm SW 24 mm ...
Страница 61: ...61 Montage 6 7 SW 30 mm 17 Nm 8 10 9 SW 22 mm 2 min SW 22 mm 2 Nm ...
Страница 62: ...62 Justierung 1 4 2 3 ...
Страница 63: ...63 Safety Function SW 2 5 mm SW 2 5 mm 1 Nm z B 42 C for example 42 C 4 3 1 2 5 6 1 2 2 1 1 ...
Страница 65: ...65 Wartung 1 2 3 SW 30 mm 1 2 SW 10 mm 4 5 SW 10 mm 20 Nm 6 1 2 SW 30 mm 17 Nm ...