Flow diagram
(see page 68)
Rate of flow by 0,3 MPa
Test certificate
(see page 68)
Dimensions
(see page 65)
English
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filter in front of the mixer
and on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or calci-
fied
-
Clean temperature regulator, ex-
change if necessary
-
For new installations: basic body in-
correctly connected (should be: cold
right, hot left) or installed with 180º
rotation
-
Install function block turned
through 180º
Safety stop button not operating
-
Spring defective
-
Clean spring and/or button, ex-
change if necessary
-
push button calcified / contaminated
Valve stiff
-
Shut-off unit damaged
-
Exchange shut-off unit
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Assembly see page 60
Cleaning
(see enclosed brochure)
Special information for UK
(see page 73)
7
Содержание Axor Carlton
Страница 60: ...60 01800180 X 11 1 2 mm 1 2 1 2 2 4 3 5 6 2 2 3 1 1 SW 4 mm 5 Nm X ...
Страница 63: ...63 z B 42 C for example 42 C 2 1 1 2 SW 3 mm 4 Nm 1a 1b 2 SW 2 mm SW 2 mm SW 3 mm 3 4 5 6 ...
Страница 64: ...64 1 2 40 C 7 8a 8b SW 2 mm 4 Nm SW 2 mm 4 Nm ...
Страница 66: ...66 Wartung 1 2 A 1 2 SW 24 mm A SW 4 mm 6 2 3 4 1a 5 1 2 3 4 1 2 3 4 1b SW 2 mm SW 2 mm S W 3 m m S W 3 m m ...
Страница 79: ...79 ...