0 6
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of alco-
hol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective coun-
tries must be observed.
⁄ This mixer cannot be used in conjunction with hydrauli-
cally, electronically or thermally controlled instantane-
ous heaters.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
F L O W D I A G R A M (see page 68)
free flow
M A I N T E N A N C E (see page 65)
⁄ The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
⁄ To guarantee the smooth running of the ther-
mostat, it is necessary from time to time to turn
the thermostat from total hot to total cold.
A D J U S T M E N T (see page 63)
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
S A F E T Y F U N C T I O N (see page 63)
The desired maximum temperature for example
max. 42º C can be pre-set thanks to the safety
function.
D I M E N S I O N S (see page 67)
O P E R A T I O N (see page 68)
C L E A N I N G (see page 80)
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
EN
S P E C I A L I N F O R M A T I O N F O R U K
(see page 74)
T E S T C E R T I F I C A T E (see page 79)
Содержание AXOR Carlton 17712 Series
Страница 24: ...2 4 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 70 C 4 68 65 DIN EN 1717 63 63 42 67 68 80 ZH 79...
Страница 59: ...5 9 1 0 5 0 1 1 6 PSI 147 10 1 70 C 65 C 70 C 4 68 65 DIN EN 1717 63 63 42 67 68 80 AR 79...
Страница 60: ...6 0 2 3 1 X 1 2 mm SW 4 mm 5 Nm 2 5 6 4 X 11 3 2 3 1 SW 5 mm 1 2 01700180 1...
Страница 64: ...6 4 2 3 2 1 1 SW 3 mm SW 3 mm z B 42 C for example 42 C 2 1 1 2 3 3 5 4 6 8a 8b 7 SW 2 mm 2 Nm...