4
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded
base
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions
(see page 36)
Flow diagram
(see page 36)
Spare parts
(see page 38)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Cleaning
(see page 37)
Operation
(see page 35)
Test certificate