background image

OPERATIONAL GUIDE

BATTERY REPLACEMENT

Battery replacement must only take place in a safe area and 
using a 9V alkaline battery.
Simply slide off the battery cover on the back of the meter, 
detach the battery from the terminals and attach a new 9V 
battery, while paying attention to the correct polarity. Replace 
the battery cover. 

ACCESSORIES

IST99556   09/18

Before using this product, make sure it is entirely suitable for 
your specific application and for the environment in which it 
is used. Any variation introduced by the user to the supplied 
equipment may degrade the meters’ performance. For yours and 
the meter’s safety do not use or store the meter in hazardous 
environments.

EMISSIVITY

The instruments measure the temperature of objects with an 
emissivity of 0.95, which is the characteristic of most substances, 
such as organic material, water, plastic, fabrics, etc. 
To measure substances that have a polished surface and are 
very reflective, the emissivity needs to be compensated. It is 
advisable to cover the object with black paint or black adhesive 
tape to compensate for the reflectivity.

WARNING

To avoid damage, do not hold the sensor too close to a heat 
source for a long period.

SENSOR CLEANING

To maintain the instrument’s accuracy, it is important that the 
sensor lens is kept clean. To clean the sensor, gently wipe the 
lens with a humid and non-abrasive cloth (

HI731318

).

EXTERNAL PROBE (HI99556 only)

Connect the 

HI765PW

 temperature 

probe to the connector on top of the 
instrument.

MEASUREMENT MODE

Press the IR/CONTACT button to select the external probe 
measurement mode: “P” appears on the LCD to indicate that 
the mode has been entered.

Dip the probe in the substance which to be measured (an 
immersion level of approximately 4 cm is recommended), and 
wait for the reading to stabilize.

LOW BATTERY

These instruments continuously check the battery status. If the 
battery level is too low to ensure realiable reading, the meter 
shuts off the LCD completely. In this case and if the meter can 
not be switched on, it is recommended to replace the battery 
immediately.

WARRANTY

HI99551 

and

 HI99556 

are warranted for two years against 

defects in workmanship and materials when used for its intended 
purpose and maintained according to instructions. Probes are 
guaranteed for a period of six months. 
This warranty is limited to repair or replacement free of 
charge. Damages due to accident, misuse, tampering or lack of 
prescribed maintenance are not covered. If service is required, 
contact your local Hanna Instruments Office. If under warranty, 
report the model number, date of purchase, serial number and 
the nature of the failure. If the repair is not covered by the 
warranty, you will be notified of the charges incurred. If the 
instrument is to be returned to Hanna Instruments, first obtain a 
Returned Goods Authorization Number from the Customer Service 
department and then send it with shipment costs prepaid. 
When shipping any instrument, make sure it is properly pack-
aged for complete protection.

INFRARED SENSOR MEASUREMENT

Switch the instrument on. 
For 

HI99556

 models, check that the 

instrument is in IR (infrared) mode.
If necessary (a “P” tag appears on the LCD to indicate “external 
probe mode”), press the IR/CONTACT button to switch to IR 
(infrared) measurement mode.

To measure the temperature 
of an object, simply aim the 
sensor in the direction of the 
object. 

READING DISTANCE

The distance between the sensor and the object is an important 
factor in infrared measurement.
The relation between “distance/object area” is 3:1. This means 
that the diameter of the measured area is one third of the 
distance between the sensor and the object.

For example, if the sensor is 15 cm away from the object, 
the instrument measures the temperature of an area with a 
5 cm diameter.

HI710007

Blue shockproof rubber boot

HI710008

Orange shockproof rubber boot

HI731318

Wiping tissue (4 pcs.)

HI765PW

Penetration thermistor probe with white handle

RECOMMENDATIONS FOR USERS

All rights are reserved. Reproduction in whole or in part is 

prohibited without the written consent of the copyright owner.

Содержание Pronto Plus HI99551 Series

Страница 1: ...www hannainst com Instruction Manual HI99551 HI99556 Infrared Thermometers for the Food Industry ...

Страница 2: ...HI99551 and HI99556 thermometers employ infrared technol ogy to measure the surface temperature Infrared measurements are extremely practical with a fast response time typically around 1 second Another main advantage is the non intrusive nature of the measurement which is particularly attractive in the food industry since it translates itself into substantial savings by leaving products intact esp...

Страница 3: ...HI99556 only 3 Liquid Crystal Display LCD 4 ON OFF button 5 IR CONTACT button to select infrared sensor or external probe HI99556 only 6 Wrist strap Hanna Instruments reserves the right to modify the design construction and appearance of its products without advance notice ...

Страница 4: ...Probe HI99556 only 0 5 C 20 to 120 C 1 F 0 to 250 F 0 5 C 1 F 1 reading outside Typical EMC Deviation IR Sensor 1 C 2 F 1 C Typical EMC Deviation Probe HI99556 only 0 5 C 1 F 0 5 C IR Sensor Response Time 1 second Optic Coefficient 3 1 ratio of distance to target diameter Minimum Distance 30 mm 1 2 Emissivity 0 95 fixed Wave Length 6 14 µm Probe HI765W included HI99556 only Battery Type 1 x 9V alk...

Страница 5: ...asure the temperature of an object simply aim the sensor in the direction of the object READING DISTANCE The distance between the sensor and the object is an important factor in infrared measurement The relation between distance object area is 3 1 This means that the diameter of the measured area is one third of the distance between the sensor and the object For example if the sensor is 15 cm away...

Страница 6: ...or lens is kept clean To clean the sensor gently wipe the lens with a humid and non abrasive cloth HI731318 EXTERNAL PROBE HI99556 only Connect the HI765PW temperature probe to the connector on top of the instrument MEASUREMENT MODE Press the IR CONTACT button to select the external probe measurement mode P appears on the LCD to indicate that the mode has been entered Dip the probe in the substanc...

Страница 7: ...minals and attach a new 9V battery while paying attention to the correct polarity Replace the battery cover ACCESSORIES HI710007 Blue shockproof rubber boot HI710008 Orange shockproof rubber boot HI731318 Wiping tissue 4 pcs HI765PW Penetration thermistor probe with white handle All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owne...

Страница 8: ...a period of six months This warranty is limited to repair or replacement free of charge Damages due to accident misuse tampering or lack of prescribed maintenance are not covered If service is required contact your local Hanna Instruments Office If under warranty report the model number date of purchase serial number and the nature of the failure If the repair is not covered by the warranty you wi...

Отзывы: