Hanna Instruments HI 98140 Скачать руководство пользователя страница 15

29

28

ACCESSORIES

pH CALIBRATION SOLUTIONS

HI 70004P

pH 4.01 buffer solution, 20 mL sachet, 25 pcs

HI 70007P

pH 7.01 buffer solution, 20 mL sachet, 25 pcs

HI 70010P

pH 10.01 buffer solution, 20 mL sachet, 25 pcs

HI 7004L

pH 4.01 buffer solution, 500 mL bottle

HI 7006L

pH 6.86 buffer solution, 500 mL bottle

HI 7007L

pH 7.01 buffer solution, 500 mL bottle

HI 7009L

pH 9.18 buffer solution, 500 mL bottle

HI 7010L

pH 10.01 buffer solution, 500 mL bottle

ELECTRODE MAINTENANCE SOLUTION

HI 70300L

Storage solution, 500 mL bottle

HI 70000P

Electrode rinsing solution, 20 mL sachet, 25 pcs

HI 7061L

General cleaning solution, 500 mL bottle

HI 7073L

Protein cleaning solution, 500 mL bottle

HI 7074L

Inorganic cleaning solution, 500 mL bottle

HI 7077L

Oil & Fat cleaning solution, 500 mL bottle

HI 7071

3.5M KCl+AgCl electrolyte solution, 4 x 50 mL bottle

HI 7072

1M KNO

3

 electrolyte solution, 4 x 50 mL bottle

HI 7082

3.5M KCl electrolyte solution, 4 x 50 mL bottle

ORP PRETREATMENT SOLUTIONS

HI 7091L

Reducing pretreatment solution, 500 mL bottle

HI 7092L

Oxidizing pretreatment solution, 500 mL bottle

• Dry Membrane/Junction:

 soak in 

HI 70300

 storage solution for

at least 1 hour

• Drifting:

 soak the electrode tip in warm 

HI 7082

 solution for one

hour, then flush tip with distilled water. Refill with fresh 

HI 7071

for single junction electrodes and 

HI 7082 

for double junction

electrodes

• Low Slope:

 refer to the cleaning procedure above

• No Slope: 

check the electrode for cracks in glass stem or bulb

and replace the electrode

• Slow Response/Excessive Drift: 

soak the tip in 

HI 7061

solution for 30 minutes, rinse thoroughly in distilled water and
then follow the Cleaning Procedure above.

SMART ELECTRODES

HI 1615D

Smart pH electrode, glass body, single junction, refill-
able, with built-in temperature sensor, DIN connector
and 1 m (3.3') cable

HI 1616D

Smart pH electrode, glass body, single junction, gel-
filled, with built-in temperature sensor, DIN connector
and 1 m (3.3') cable

HI 1617D

Smart pH electrode, glass body, single junction, triple
ceramic, refillable, with built-in temperature sensor,
DIN connector and 1 m (3.3') cable

HI 1618D

Smart pH electrode, plastic body, single junction, gel-
filled, with built-in temperature sensor, DIN connector
and 1 m (3.3') cable

HI 3619D

Smart ORP/Pt electrode, glass body, single junction,
with DIN connector and 1 m (3.3') cable

HI 3620D

Smart ORP/Pt electrode, glass body, single junction,
gel-filled, with DIN connector and 1 m (3.3') cable

FC 201D

Smart pH electrode, single junction, with built-in
temperature sensor, DIN and 1 m (3.3') cable

FC 212D

Smart pH electrode, double junction, with built-in
temperature sensor, DIN and 1 m (3.3') cable

FC 231D

Smart pH electrode, single junction, with penetration
blade (20 mm / 0.79"), built-in temperature sensor,
DIN connector and 1 m (3.3') cable

FC 241D

Smart pH electrode, single junction, with penetration
blade (35 mm / 1.38"), built-in temperature sensor,
DIN connector and 1 m (3.3') cable

OTHER ACCESSORIES

HI 710005

Voltage adapter, 115 Vac / 12 Vdc

HI 710006

Voltage adapter, 230 Vac / 12 Vdc

HI 76405

Electrode holder

HI 8427

pH and mV simulator

HI 931001

pH and mV simulator with LCD display

HI 92000

Windiws

®

 compatible software

HI 920011

Serial cable for PC connection (5 to 9-pin)

Содержание HI 98140

Страница 1: ...nual HI 98140 HI 98150 Portable Waterproof pH ORP Meters with Smart Electrodes Log On Demand 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquip...

Страница 2: ...so incorporates a temperature sensor elimi nating the need for an additional temperature probe HI 98140 and HI 98150 feature all the most advanced features of laboratory pH meters Moreover they are pr...

Страница 3: ...ed data with ALT These instruments also feature a controlled access to calibration and GLP settings through a password protection method The Battery Error Preventing System BEPS detects when the batte...

Страница 4: ...re turning the meter off If the meter is OFF detach the electrode from the meter before immersing it in the storage solution ON OFF SPECIFICATIONS Range 4 00 to 19 99 pH 20 to 120 0 C HI 98150 only 60...

Страница 5: ...8 10 Calibration alarm time out 01 99 days OFF OFF 20 Auto Off Power down time out ON OFF ON 21 Firmware version 22 Battery level test 99 Password2 0000 9999 0000 Setup can be used to view data regard...

Страница 6: ...to change them pressing ALT and FNC with no need to enter setup mode Note If measurements are taken successively in different samples it is recommended to rinse the electrode thoroughly with deion iz...

Страница 7: ...om 0000 with the arrow keys 4 Press ALT and CFM to confirm the password or CAL to exit 5 If password is correct the meter displays 7 01pH on the lower LCD with the BUF 1 and CAL indication The upper L...

Страница 8: ...be displayed to alert the user 10 If only a single point calibration is re quired press CAL to exit the calibration mode and maintain the previous slope calibration The instrument then checks the ele...

Страница 9: ...tion at 0 0 50 0 C has to be performed in order to store the new calibration data in memory 1 Immerse the pH electrode with the built in temperature sensor in the 0 C temperature bath 2 Press ALT and...

Страница 10: ...hat an ORP electrode was connected mV reading HI98150 only means reading out of range temperature reading means reading out of range GLP message If RANGE is pressed when the GLP message is displayed t...

Страница 11: ...I98140 and HI98150 use electrodes with a built in EEPROM in which calibration data are read at start up and stored after calibration The meter can automatically analyze the data and advise the user if...

Страница 12: ...T The LCD can be illuminated to allow the user to see the readings even in dark environments It can be enabled disabled through the LIGHT key and it is automatically disabled when batter ies are in lo...

Страница 13: ...charged batteries The backlight can be enabled 2 Weakening batteries The backlight is automatically disabled and it is not possible to enable it until new batteries are inserted or an external power...

Страница 14: ...tuate up and down could be due to Clogged Dirty Junction refer to the cleaning procedure above Loss of shielding due to low electrolyte level for refillable electrodes only refill with fresh HI 7071 f...

Страница 15: ...ctrode Slow Response Excessive Drift soak the tip in HI 7061 solution for 30 minutes rinse thoroughly in distilled water and then follow the Cleaning Procedure above SMART ELECTRODES HI 1615D Smart pH...