Remove the instrument from the packing material and examine it to make sure that
no damage has occurred during shipping. If there is any damage, notify your Dealer.

HI 93124 

is supplied complete with:

Glass Cuvet & Cap (2 pcs.)

1.5V AA alkaline batteries (4 pcs.)

Instruction manual

Rugged carrying case

Note:

 Save all packing material until you are sure that the meter functions

correctly. All defective items must be returned in its original packaging
with the supplied accessories.

PRELIMINARY EXAMINATION

Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the meter.
This manual will provide all necessary information for a correct use.
If you need additional technical information, do not hesitate to e-mail us at

[email protected]

 or contact your nearest technical office.

This instrument is in compliance with the 

 directives.

TABLE OF CONTENTS

All Hanna Instruments

 meters are warranted for two years 

against defects in

workmanship and materials when used for their intended purpose and maintained
according to instructions.
This warranty is limited to repair or replacement free of charge. Damage due to
accidents, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument.
If under warranty, report the model number, date of purchase, serial number and
the nature of the problem. If the repair is not covered by the warranty, you will be
notified of the charges incurred. If the instrument is to be returned to Hanna
Instruments, first obtain a Returned Goods Authorization number from the Customer
Service department and then send it with shipping costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete protection.

WARRANTY

Warranty ................................................................................... 3

Preliminary Examination ............................................................. 3

Principle of Operation ................................................................. 4

General Description ..................................................................... 4

Functional Description ................................................................. 5

Specifications ............................................................................. 6

Operational Guide ..................................................................... 7

Taking measurements ......................................................... 7
Sources of interference ......................................................... 8
Log-on-demand .................................................................. 8
Cleaning logged data ......................................................... 8
Viewing logged data .......................................................... 9
Viewing and setting date and time ..................................... 9

RS232 connection ...................................................................... 9

Calibration .............................................................................. 10

Calibration procedure ........................................................ 10
Viewing calibration date ................................................... 11
Standard suspension ........................................................ 11

Tips for accurate operation ........................................................ 12

LCD error codes ........................................................................ 13

Battery Replacement ................................................................ 14

Accessories ............................................................................... 14

CE declaration of conformity ...................................................... 15

Содержание HI 93124

Страница 1: ...1 Instruction Manual HI 93124 Portable Logging Haze Meter w w w h a n n a i n s t c o m...

Страница 2: ...instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintenance are not covered If service is required contact...

Страница 3: ...epolyphenol polymerizes A range of stabilization treatments is available for avoiding haze problems and theproducthastobecontrolledonseveralstepsduringbrewingprocess inparticular after filtration and...

Страница 4: ...withalint freetissue HI731318 before inserting into the measure ment cell Thecuvettemustbecompletelyfreeoffingerprints andotheroilordirt particularlyintheareawhere the light goes through approximately...

Страница 5: ...availableinstrumentsoperating in the range of visible light Air bubbles and the effect of vibrations that disturb the surface of the sample willgivefalseresults Dirtyglasswarecouldalsoaffectreadingsal...

Страница 6: ...from stock solutions TheconsistencyofHI93124readingsbyusingbothstandardshasbeenseparately established by Advanced Polymer Systems and Hanna Instruments Additional documentation about the formazine sta...

Страница 7: ...ette cap always to the same degree Beforeinsertingthecuvetteintotheinstrument wipeitwithsoft lint freetissue Handlecuvettessothatnofingerprintscangetontheareaswherelightpasses approximately 2 cm 1 inc...

Страница 8: ...4 1 HI 93124 2 HI731318 Tissue for wiping cuvettes 4 pcs HI 731321 Spare measurement cuvettes 4 pcs HI92000 Windows compatibleapplicationsoftware HI920011 5 to 9 pin RS232 connection cable HI 93703 50...

Страница 9: ...3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiw...

Отзывы: