SETTING DATE, TIME & PRINTING INTERVAL
WITH HI 9161

When the instrument is turned on, the dis-
play shows the TIME.

Press the INTV and RANGE keys simultaneously. The display will then
show the date previously memorized with the year blinking (shown as
the last 2 digits of the year, e.g. 95=1995).

Use the UP and DOWN keys to select the year.

When the correct year is selected, press the RANGE key once and the
month will start blinking.

Select the correct month by pressing the UP or DOWN keys.

Press RANGE and the day will start blinking.

Use the UP or DOWN keys to select the correct day. The day will still
blink.

TIME

INTV

INTV

RANGE

+

DATE

UP

DOWN

RELATIVE HUMIDITY MEASUREMENTS

Operations with the 

HI 9161 

and 

HI 91610 

are very simple.

For accurate measurements, the RH sensor should be exposed to a
current of air moving at 0.5 m (20") per second or more.

In the absence of air movement, the response can be accelerated
by moving the probe.

• The probe sensor must never come into contact with water

or any other liquid

. If this happens, or if condensation causes

drops to form on the surface of the humidity sensor, the instru-
ment must be turned off until moisture has completely evaporated.
To accelerate the evaporation process, expose the humidity sensor
to a current of air.

For any problem in taking measurements, please contact your dealer
or the nearest HANNA Customer Service Center.

TEMPERATURE MEASUREMENTS

The 

HI 762L/2

 temperature probe supplied with theinstrument is a

liquid/general purpose probe with 2 m (6.6') cable.
Simply plug the probe into the socket located on the top of the meter.
If continuous monitoring of temperature is needed, keep the probe
attached to the meter at all times.
To view either the RH% or temperature read-
ing on the display, press RANGE. The reading
will appear without decimal digit when shown
on the secondary display. The temperature
range on the secondary display goes from 0
to 99°C (or °F).
If the temperature exceeds this range, "--"
will appear indicating that the secondary
display is unable to show the reading.
If no probe or test plug is connected, the
meter will display and print "----" to alert the
user. This could also indicate that the probe
cable is damaged.
HANNA offers a wide range of temperature probes to meet all
application requirements. HANNA 

HI 762

 probe series use highly

sensitive thermistor sensors to provide great accuracy and fast response
(see "Accessories" section for a complete list).

OPERATIONAL GUIDE

RANGE

RANGE

UP

DOWN

RANGE

UP

DOWN

Содержание HI 91610

Страница 1: ...9161C ON OFF PAPER RANGE RH 5 0 95 0 C 20 0 60 0 INTV instrum nts e UP PRINT DOWN RANGE LOG MICROPROCESSOR PRINTING THERMOHYGROMETER HI 9161 HI 91610 Printing and Logging Thermo Hygrometers w w w h a...

Страница 2: ...CIFICATIONS 8 INITIAL PREPARATION 9 OPERATIONAL GUIDE 10 PRINTING RECORDING WITH HI 9161 17 PRINTING LOGGING WITH HI 91610 19 CALIBRATION 24 DATA TRANSFER TO PC HI 91610 only 27 SELF DIAGNOSTIC FUNCTI...

Страница 3: ...ecording printing interval relative humidity and temperature at user selectable intervals Both RH and temperature are measured with 0 1 resolution HI 91610 combines the high accuracy and portability o...

Страница 4: ...terval 6 TIME key to display current time and printing interval or to set date time printing interval with ALT 7 LOG key to start stop logging with ALT 8 LCD Liquid Crystal Display 9 PAPER key to adva...

Страница 5: ...se However when in recording logging mode the meter will continue to monitor RH and temperature To reactivate the display press RANGE INITIAL PREPARATION ON OFF RANGE RANGE SPECIFICATIONS HI 9161C HI...

Страница 6: ...ff until moisture has completely evaporated To accelerate the evaporation process expose the humidity sensor to a current of air For any problem in taking measurements please contact your dealer or th...

Страница 7: ...ng The printing interval on the secondary LCD will blink Any interval can be selected from among 1 2 5 10 15 30 60 120 and 180 minutes by using the UP and DOWN keys Once the desired interval is select...

Страница 8: ...red in the memory even when the meter or display are switched off Note Each time the batteries are replaced the settings will need to be re entered This can be avoided by applying an external voltage...

Страница 9: ...YY d Printing interval in minutes e Time HH MM f RH value g Temperature value When the meter is in recording mode LOG is displayed on the secondary LCD with the RH value on the primary LCD PRINT LOG V...

Страница 10: ...will print a complete set of data and the LOG symbol will appear on the secondary LCD Press the ALT and PAPER keys at the same time and the LOG symbol on display will start to blink If no key is press...

Страница 11: ...DOWN TIME LOG ALT RANGE LOG TIME To reactivate the display press the TIME key Notes Once in the logging mode the interval cannot be changed Exit the logging mode press ALT and LOG together and then s...

Страница 12: ...the recall mode press the LOG key Note This mode will not alter data already present in the memory PRINTING STORED DATA Once a log number is selected all or part of that logged section can be printed...

Страница 13: ...Na Cl 75 4 CALIBRATION KIT 12 3 6 9 4 h CALIBRATION KIT Li Cl 11 1 Na Cl 75 4 12 3 6 9 4 h All HANNA thermo hygrometers have been precalibrated at the factory HANNA instruments uses state of the art...

Страница 14: ...0 you need a 3 5 drive and a couple of minutes to follow the short instructions conveniently printed on the disk label TIME Windows is a registered Trademark of Microsoft Co Excel Copyright of Microso...

Страница 15: ...s for about 1 minute Remember to reset time and date once the batteries have been reinserted ATTENTION If batteries need to be replaced and data is not to be lost power the meter through a 12 Vdc adap...

Страница 16: ...er the cover preventing the pa per from advancing Replace the battery cover and tighten the screws 1 5V 1 5V 1 5V 1 5V SCREW POTS RESET CHANGING THE INK CARTRIDGE When printouts become faint it might...

Страница 17: ...handle HI 762BL Liquid probe with 1 m 3 3 cable black handle HI 762BL 10 Liquid probe with 10 m 33 cable black handle HI 762L Liquid probe with 1 m 3 3 cable white handle HI 762L 10 Liquid probe with...

Страница 18: ...the probe socket on the meter If the reading differs by more than 0 4 C 0 8 F from the test key value the unit is due for recalibration Choose the proper test key according to your application needs H...

Страница 19: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Отзывы: