background image

9

8

Check the highest or lowest measured tem-
perature by pressing the respective HI or
LO key. The appropriate display indicator,
"HI" or "LO",  will light up together with the
value retrieved from memory.

Release the key to resume normal opera-
tion.

CLEAR HI-LO FUNCTION (HI 9057
only)

By pressing HI and LO simultaneously the
present measurement reading is assigned in
memory as the highest and lowest tempera-
ture reading, i.e. both "HI" and "LO" will
have equal temperature readings.

MEMORY FUNCTION (HI 9056 only)

The memory & hold function is activated by
MEM HOLD. The measured temperature is
stored in memory and frozen on the display
when this function key is pressed and held.

LO

°C

HI

°C

MEM

HOLD

To change the scale, press °C/°F once.

MEASUREMENT RESOLUTION

When switched on, 

HI  9056

and 

HI  9057 

default to a 0.1

digit resolution (see specifi-
cations).
These instruments automatically change  the
resolution to 1 degree when the measured
temperature is higher than 999.9°C.
In 

HI 9056

, when the tem-

perature is lower than
999.9°C it is possible to
change the resolution by
pressing the 0.1/1 key.

HOLD MODE (HI 9057 only)

The reading hold function is activated by
the HOLD key.
To freeze the measured temperature on the
display, press and hold the HOLD key.
"HOLD" is displayed when this key is pressed.

As soon as the HOLD key is released, the
meter returns to normal operational mode.

HI-LO FUNCTION (HI 9057 only)

Maximum and minimum temperatures are
monitored throughout a continuous measur-
ing process.
The values may be recalled or cleared at
any time during the measurement.

°C

°F

°F

°C

HOLD

Содержание HI 9057

Страница 1: ...Instruction Manual HI 9056 HI 9057 Portable Microprocessor Thermocouple Thermometers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives...

Страница 2: ...9056 5 Functional Description Specifications of HI 9057 6 Operational Guide 7 Display Codes Guide 11 Calibration 12 Battery Replacement 12 Shockproof Rubber Boots 13 Accessories 14 Warranty 18 CE Decl...

Страница 3: ...sions 180 x 83 x 40 mm 7 1 x 3 3 x 1 6 Weight 350 g 12 4 oz FUNCTIONAL DESCRIPTION AND SPECIFICATIONS FOR HI 9056 Standard features include Interchangeable probes Clear Liquid Crystal Display Two year...

Страница 4: ...the C scale Measurements can be performed on either the Centigrade or the Fahrenheit scale BAT HOLD K J T C F HI LO ON OFF 1 Liquid Crystal Display 2 ON OFF Key 3 Reading Memory Hold Key 4 Thermocoup...

Страница 5: ...OLD To change the scale press C F once MEASUREMENT RESOLUTION When switched on HI 9056 and HI 9057 default to a 0 1 digit resolution see specifi cations These instruments automatically change the reso...

Страница 6: ...reading in the Centigrade scale F The instrument is reading in the Fahrenheit scale HI Displays the highest measured temperature LO Displays the lowest measured temperature HOLD Freezes current readin...

Страница 7: ...alibrated at least once a year For an accurate annual recalibration con tact your nearest Hanna Service Center BATTERY REPLACEMENT When the battery is low the user is warned by the BAT indication on t...

Страница 8: ...66B Surface probe max 650 C 1200 F 420mm 13 3 280mm 11 100mm 4 16 5 400mm 15 7 260mm 10 2 155mm 6 1 3mm 0 12 200mm 7 8 5mm 0 20 100mm 4 280mm 7 8 3mm 0 12 155mm 6 1 250mm 9 8 3mm 0 12 11 200mm 7 9 ACC...

Страница 9: ...cessories HI 710002 Soft carrying case HI710009 Blue rubber boot HI710010 Orange rubber boot 300mm 11 8 30mm 1 2 130mm 5 1 8mm 0 3 HI 766B1 90 surface probe max 450 C 840 F HI 766B2 Surface probe max...

Страница 10: ...e probes are guaranteed for a period of six months This warranty is limited to repair or replacement free of charge Damage due to accident misuse tampering or lack of prescribed maintenance are not co...

Страница 11: ...ations The reference literature currently covers areas such as Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry and many others New reference material is constantly being...

Отзывы: