The pH, EC and solar radiation sensors have be connected to the analog inputs through the transmit-
ters, that have 4-20mA (source current type) outputs and 0-2V (solar radiation). The Hanna
transmitters that can be used are HI98143-22 (1 pH, 1 EC). The user can or can not use the second pH,
EC sensors or the pH input sensor. The number os EC, pH sensors is configured within panel S55 -
SENSOR CONFIG.
The EC-in sensor can be replaced from installation without modifications. Thus, the “EC-in “ input will
stay unconnected.
The transmitters will be supplied from the +/-Vs outputs. The maximum consumption supported by
the controller is around 250mA (12V). This means that two Hanna transmitters can be supplied from
the same output (2 pH channels and 2 EC channels) and one transmitter for the EC-in sensor.
The following type of sensors can be connected to the transmitters:
HI 1001
HI 1001
HI 1001
HI 1001
HI 1001 Plastic in-line pH electrode
HI 3001
HI 3001
HI 3001
HI 3001
HI 3001 4-ring conductivity probe
2.2.5 V
2.2.5 V
2.2.5 V
2.2.5 V
2.2.5 Valve connections
alve connections
alve connections
alve connections
alve connections
The valves have to be connected as in the following figure. Each group of 8 valves has a common pin
placed near the valve’s output called COM OUT 1, 2, 3. The valves are not supplied from the controller.