12
Program 4
Program 4
Program 4
Program 4
Program 4
Irrig ctrl mode (S53): Sets time mode
Active Timetable (S31): sets a valid range for the current day
Set priority (S33): sets 1 priority
Start conditions (S34): sets External tank 04
Set program repeats (S36): sets 0
Pre/post Irrig. (S37): sets 1s
Set sectors (S38): sets 4s for valves 1, 2, 3, 4, 9, 10, 11, 12, 16, 17, 18, 19, 24, 25, 26, 27
Set fertilizers (S39): 20%, 40%, 60%, and 80%
PH control (S40): sets Ref = 7.0; –0.6 ; +0.6; threshold 2
Cond control (S41): sets Ref = 7.0; -0.6; +0.6
Filter control (S46):
After finishing these settings, the following things can be demonstrated:
· Program 1 started
by time.
Allows verifying the: start times, set valves and irrigation time.
· Program 2 started
by external tank 02.
Allows verifying the: start condition, set valves and irrigation time.
· Program 3
with repetitions.
Allows verifying the: start condition (ext. tank 03), set valves, irrigation time and repetitions.
· Program 4
liked by another program.
Allows verifying the: start condition (ext. tank 04), set valves and the irrigation time.
Sets the Start conditions (S34): link 2.
Starts the program 2 (ext. tank 02)
Allows verifying the: link with program 2.
·
Manual started.
Goes in S47 and starts manually program 2.
· The program
priorities
Starts program 3 (ext. tank 03) and immediately starts program 2 (ext. tank 02). Program 2 has
a high priority and should be activated (program 3 goes in suspend state). After that, program
2 is finished and program 3 is reactivated.
· The
alarms
Generates a low level in the mixing tank (simulator).
The ALARM led will blink and this setting is available on panel C25.
Modify the pH 1 sensor value. When the value is out of the set range, a new alarm is generated
(C25). Modify the pH2 sensor value to obtain a difference between pH1 and pH2 bigger that