Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during shipment.
If there is any damage, notify your Dealer.
Each HI 83215 Meter is supplied complete with:

• Four Sample Cuvets and Caps
• One Transport Cap
• 2x 9 V  Battery
• 12 VDC Transformer (

HI 710005

 or 

HI 710006)

Note:

Save all packing material until you are sure that the instrument
functions correctly. Any defective item must be returned in its
original packing with the supplied accessories.

HI 83000 Series is a line of 17 different bench, microprocessor-based
photometers that measure more than 50 parameters in water and
wastewater. These multipurpose meters are manufactured to measure
the most important parameters of the application they have been
especially designed for:
HI 83099 Laboratories, with COD

HI 83200 Laboratories

HI 83203 Aquaculture

HI 83205 Boilers & Cooling Towers

HI 83206 Environmental Testing

HI 83207 Industrial Wastewater

HI 83208 Water Conditioning

HI 83209 Education

HI 83210 Pulp & Paper Mills

HI 83211 Chemical Manufacturers

HI 83212 Power Plant Utilities

HI 83213 Municipal Wastewater

HI 83214 Wastewater Treatment Applic. HI 83215 Nutrient Analyses
HI 83216 Pool & Spa Applic.

HI 83218 Environmental Applic.

HI 83226 Pool & Spa Applic.
All meters use an exclusive positive-locking system to ensure that the
cuvet is in the same position every time it is placed into the
measurement cell.
The reagents are in liquid or powder form and are supplied in bottles
or in packets. The amount of reagent is precisely dosed to ensure the
maximum repeatability.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature, turning the unit off after 10
minutes of non-use.
The HI 83000 Series can be connected to a personal computer via the
HI 920010 three wire RS 232 cable. The HI 92000 Hanna Windows

®

Compatible Software aids the user to manage all test data.

PRELIMINARY EXAMINATION

GENERAL DESCRIPTION

50

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the environment in which
they are used.
Operation of these instruments in residential area could cause unacceptable interferences to radio
and TV equipments, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance.
To avoid damages or burns, do not perform any measurement in microwave ovens.

CE DECLARATION OF CONFORMITY

Содержание C 215

Страница 1: ...struction Manual C 215 HI 83215 Grow Master Basic for Nutrient Analyses This Instrument is in Compliance with the CE Directives w w w h a n n a i n s t c o m MANC215R6 01 05 w w w h a n n a i n s t c o m ...

Страница 2: ...MR 35 PHOSPHORUS HR 37 POTASSIUM LR 39 POTASSIUM MR 41 POTASSIUM HR 43 POTASSIUM UHR 45 INTERFACE WITH PC 45 STANDARD METHODS 47 BATTERY REPLACEMENT 47 ACCESSORIES 48 WARRANTY 49 CE DECLARATION OF CONFORMITY 50 HANNA LITERATURE 51 All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Hanna Instruments Inc Woonsocket Rhode Island 0...

Страница 3: ...mentApplic HI 83215 Nutrient Analyses HI 83216 Pool Spa Applic HI 83218 Environmental Applic HI 83226 Pool Spa Applic All meters use an exclusive positive locking system to ensure that the cuvet is in the same position every time it is placed into the measurement cell The reagents are in liquid or powder form and are supplied in bottles or in packets The amount of reagent is precisely dosed to ens...

Страница 4: ...he substance as the other factors are known Photometric chemical analysis is based on the possibility to develop an absorbing compound from a specific chemical reaction between sample and reagents SPECIFICATIONS PRINCIPLE OF OPERATION 49 All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained accordin...

Страница 5: ...ention It is important that both the measurement and the calibration zeroing cuvets are optically identi cal to provide the same measurement conditions Whenever possible use the same cuvet for both It is also necessary that the surface of the cuvet is clean and not scratched This is to avoid measurement interference due to unwanted reflection and absorption of light It is recommended not to touch ...

Страница 6: ...LR 10 0 0 to 20 0 mg L Turbidimetric Potassium MR 11 10 to 100 mg L Turbidimetric Potassium HR 12 20 to 200 mg L Turbidimetric Besides to the 12 VDC supply this meter can also be fed by two 9V batteries To prolong battery life switch your meter off after use However the meter has an auto shut off feature that will turn itself off after 10 minutes of non use A blinking LOBAT on the display while a ...

Страница 7: ... TO DISPLAY CODES 46 PUP Program Up PDN Program Down PTM Turn Test Mode On Brx Set the baud rate 1 300 2 600 3 1200 4 2400 KBL Lock Keyboard KBU Unlock Keyboard PR Send Current Program Number 1 to 12 BRQ Send current baud rate 1 150 2 300 3 600 4 1200 5 2400 CNQ Send Concentration three bytes conc decimal point unit m ppm b ppb t ppt u pcu h pH ERR send error status information 0 No error 1 CAP 2 ...

Страница 8: ...the other into the serial port of your PC Note Cables other than HI 920010 may use a different configura tion in which case communication between the meter and the PC may not be possible SETTING THE BAUD RATE The transmission speed baud rate of the meter and the external device must be identical The meter is factory set to 2400 If you wish to change this value please contact your nearest Hanna Cen...

Страница 9: ...or the sample measurement Please check if the right sample cuvet is inserted 44 Press ZERO and SIP will appear on the display Wait for a few seconds and the display will show 0 0 Now the meter is zeroed and ready for measurement Remove the cuvet and add the content of one packet of HI 93750B reagent Re place the cap and mix gently for one minute by turning slowly the cuvet up side down Reinsert th...

Страница 10: ...etric Tetraphenylborate method The reaction between Potassium and reagents causes turbidity in the sample REQUIRED REAGENTS Code Description Quantity HI 93750A A A A A 0 Potassium Reagent 6 drops HI 93750B B B B B 0 Powder Reagent 1 packet REAGENT SETS HI 93750 01 Reagents for 100 tests HI 93750 03 Reagents for 300 tests For other accessories see page 48 MEASUREMENT PROCEDURE Note for sample prepa...

Страница 11: ... and add the content of one packet of HI 93750B reagent Re place the cap and mix gently for one minute by turning slowly the cuvet up side down Reinsert the cuvet into the instrument Press TIMER and the display will show the countdown prior to the measurement or alternatively wait for 2 minutes and press READ DIRECT In both cases SIP will blink during measurement The instrument directly displays c...

Страница 12: ...hod The reaction between Potassium and reagents causes turbidity in the sample REQUIRED REAGENTS Code Description Quantity HI 93750A A A A A 0 Potassium Reagent 6 drops HI 93750B B B B B 0 Powder Reagent 1 packet REAGENT SETS HI 93750 01 Reagents for 100 tests HI 93750 03 Reagents for 300 tests For other accessories see page 48 MEASUREMENT PROCEDURE Note for sample preparation follow the NUTRIENTS...

Страница 13: ...ge UHR UHR UHR UHR UHR Ultra High Range ABBREVIATIONS 40 Press ZERO and SIP will appear on the display Wait for a few seconds and the display will show 0 0 Now the meter is zeroed and ready for measurement Remove the cuvet and add the content of one packet of HI 93750B reagent Re place the cap and mix gently for one minute by turning slowly the cuvet up side down Reinsert the cuvet into the instru...

Страница 14: ...ar phosphorus assists a bigger production for both size and number of fruits SHORTAGE slower growth EFFECTS smaller leaves yellowing of leaves smaller fruits premature ripening EXCESS EFFECTS reduction in resistance to diseases and atmo spheric agents increase of water demand caused by an excessive production of leaves bad quality of fruits delayed ripening reduction in potassium absorption INTROD...

Страница 15: ...reases the cuticular thickness regulates the cellular turgidity helps to regulate the osmotic processes and increases the resistance to dryness regulates the stomatic opening and closing it means a strong influence on transpiration and photo synthesis SHORTAGE slower growth EFFECTS smaller fruits less colored and less preserved increase of transpiration less resistance to the cold 38 Phosphorus HR...

Страница 16: ...the concentration of substances Medium range usually covers the analysis of residual solutions in recycling systems The nutritive elements are differently absorbed by the plants hence the nutrient solution loses substances becomes impoverished and must be enriched High range normally corresponds to the typical values of nutrients solutions It is therefore possible to verify that the solution given...

Страница 17: ...GATION WATER LR Measure with the graduated cylinder about 100 mL of sample If the solution con tains some turbidity or color pour it in the large 170mL beaker and add a powder packet of active car bon SAMPLE PREPARATION 36 Phosphorus MR x 1 0 Wait for a few seconds and the display will show 0 0 Now the meter is zeroed and ready for measurement Remove the cuvet Add 10 drops of HI 93706A Molybdate r...

Страница 18: ... SPECIFICATIONS Range 0 0 to 50 0 mg L Resolution 0 5 mg L Accuracy 2 5 mg L 4 of reading Typical EMC Dev 0 5 mg L Light Source Tungsten lamp with narrow band interference filter 525 nm Method Adaptation of the Standard Methods for the Examination of Water and Wastewater 18th edition Amino Acid method The reaction be tween phosphorus and reagents causes a blue tint in the sample REQUIRED REAGENTS ...

Страница 19: ...ice to add to the graduated cylinder exactly 10 mL of sample Note To measure exactly 5 mL of 34 Phosphorus LR x 1 0 Wait for a few seconds and the display will show 0 0 Now the meter is zeroed and ready for measurement Remove the cuvet Add 10 drops of HI 93706A Molybdate reagent Add the content of one packet of HI 93706B 0 Phosphorus Reagent B Amino Acid to the cuvet Replace the cap and shake gent...

Страница 20: ...0 5 mg L 4 of reading Typical EMC Dev 0 1 mg L Light Source Tungsten lamp with narrow band interference filter 525 nm Method Adaptation of the Standard Methods for the Examination of Water and Wastewater 18th edition Amino Acid method The reaction be tween phosphorus and reagents causes a blue tint in the sample REQUIRED REAGENTS Code Description Quantity HI 93706A 0 Molybdate 10 drops HI 93706B 0...

Страница 21: ...Press ZERO and SIP will blink on the display Ammonia LR AMMONIA LOW RANGE 32 Nitrate HR Remove the cuvet and add the content of one packet of HI 93728 reagent Replace the cap and imme diately shake vigorously for exactly 10 seconds by mov ing the cuvet up and down Continue to mix by invert ing the cuvet gently and slowly for 50 seconds while taking care not to induce air bubbles A deposit re mains...

Страница 22: ...ill show 0 0 Now the meter is zeroed and ready for measurement Ammonia LR x 4 31 SPECIFICATIONS Range 0 to 300 mg L Resolution 5 mg L Accuracy 10 mg L 8 of reading Typical EMC 5 mg L Deviation Light Source Tungsten lamp with narrow band interference fil ter 525 nm Method Adaptation of the cadmium reduction method The reaction between nitrate nitrogen and the reagent causes an amber tint in the sam...

Страница 23: ...Press ZERO and SIP will blink on the display Ammonia MR AMMONIA MEDIUM RANGE 30 Nitrate MR Remove the cuvet and add the content of one packet of HI 93728 reagent Replace the cap and imme diately shake vigorously for exactly 10 seconds by mov ing the cuvet up and down Continue to mix by invert ing the cuvet gently and slowly for 50 seconds while taking care not to induce air bubbles A deposit re ma...

Страница 24: ...display will show 0 0 Now the meter is zeroed and ready for measurement x 4 29 SPECIFICATIONS Range 0 to 150 mg L Resolution 2 5 mg L Accuracy 5 mg L 8 of reading Typical EMC 2 5 mg L Deviation Light Source Tungsten lamp with narrow band interference fil ter 525 nm Method Adaptation of the cadmium reduction method The reaction between nitrate nitrogen and the reagent causes an amber tint in the sa...

Страница 25: ...IP will blink on the display 1 0 m L Ammonia HR AMMONIA HIGH RANGE 28 Remove the cuvet and add the content of one packet of HI 93728 reagent Replace the cap and imme diately shake vigorously for exactly 10 seconds by mov ing the cuvet up and down Continue to mix by invert ing the cuvet gently and slowly for 50 seconds while taking care not to induce air bubbles A deposit re mains but this does not...

Страница 26: ...isplay will show 0 0 Now the meter is zeroed and ready for measurement x 4 27 SPECIFICATIONS Range 0 0 to 30 0 mg L Resolution 0 5 mg L Accuracy 1 0 mg L 8 of reading Typical EMC 0 5 mg L Deviation Light Source Tungsten lamp with narrow band interference fil ter 525 nm Method Adaptation of the cadmium reduction method The reaction between nitrate nitrogen and the reagent causes an amber tint in th...

Отзывы: