be used as the “Send” (or “Dial”) key. If set to “Yes”,
pressing this key will immediately trigger the sending of
dialed string collected so far. In this case, this key is
essentially equivalent to the “(Re)Dial” key. If set to
“No”, this “#” key will then be included as part of the dial
string to be sent out.
SUBSCRIBE for MWI
Default is No. When set to “Yes” a SUBSCRIBE for
Message Waiting Indication will be sent periodically.
FXO PORT SETTING
Setting Options
Meaning
Send Anonymous
If this parameter is set to “Yes”, the “From” header in
outgoing INVITE message will be set to anonymous,
essentially blocking the Caller ID from displaying.
Session
Expiration
Default is 180 seconds.
Min-SE
Default is 90 seconds
Caller
Request
Timer
Default is NO
Callee Request
Timer
Default is NO
Force Timer
Default is NO
UAC Specify
Default is Omit