Operation Manual – MPLS TE
H3C S9500 Series Routing Switches
Chapter 1 MPLS TE Configuration
1-35
To do…
Use command to…
Remarks
Assign a metric to the
MPLS TE tunnel
mpls te igp metric
{
absolute
|
relative
}
value
Optional
The metrics of TE tunnels
equal the metrics of their
corresponding IGP routes
by default.
Submit current tunnel
configuration
mpls te commit
Required
Exit to system view
quit
––
Enter IS-IS view
isis
[
process-id
]
Enter OSPF view
ospf
[
process-id
]
Configure one of the
commands as needed.
Enable the IGP shortcut
function
enable
traffic-adjustment
Required
Disabled by default
2) Configure forwarding adjacency
Follow these steps to configure forwarding adjacency:
To do…
Use command to…
Remarks
Enter system view
system-view
––
Enter MPLS TE tunnel
interface view
interface tunnel
tunnel-number
––
Enable IGP to advertise
the route of the MPLS TE
tunnel to IGP neighbors.
mpls te igp advertise
[
hold-time value
]
Required
Routes of MPLS TE
tunnels are not advertised
to IGP neighbors by
default.
Assign a metric to the
MPLS TE tunnel
mpls te igp metric
{
absolute
|
relative
}
value
Optional
The metrics of TE tunnels
equal the metrics of their
corresponding IGP routes
by default.
Submit current tunnel
configuration
mpls te commit
Required
Exit to system view
quit
––
Enter IS-IS view
isis
[
process-id
]
Enter OSPF view
ospf
[
process-id
]
Configure one of the
commands as needed.
Enable forwarding
adjacency
enable
traffic-adjustment
advertise
Required
Disabled by default