background image

 

 

 

 
 
 
 
 
 

Operating Manual 

VARIOhab measuring system 

 

(type 73503 - 73509) 

 

 

 

 

 

 
 

 

 
 
 
 
 
 
 
 

 

 

BA 073503.00 EN 

Содержание 73503

Страница 1: ...Operating Manual VARIOhab measuring system type 73503 73509 BA 073503 00 EN...

Страница 2: ...ing and Completeness The operating manual is part of the delivery package and must be available to authorised personnel at all times It is impermissible to delete chapters from this manual If the oper...

Страница 3: ...media and the installation situation Applicable and generally recognised safety rules as well as the operating manual instructions must be followed during assembly and disassembly in operation and du...

Страница 4: ...tes a possible functional impairment or material damage Note Important additional information tips and recommendations 2 2 Safety Instructions Note The following safety information must be considered...

Страница 5: ...y tasks Caution danger zone Malfunction due to incorrect handling If the measuring system is not checked or serviced at regular intervals it may not work properly Check and maintain the measuring syst...

Страница 6: ...em Both vertical and horizontal installation is possible Installation of the measuring sensors in the VARIOhab system occurs via respective closing plates with an adapter Measuring sensors for pressur...

Страница 7: ...IP SIP 0 95 C 140 C Dimensions DN a mm b mm c mm 25 55 32 29 32 55 35 35 40 70 39 41 50 70 45 53 65 80 53 70 80 90 61 85 100 100 70 104 125 125 83 129 150 125 95 154 4 5 System Design VARIOhab process...

Страница 8: ...rs 073503 Blind plate 073504 Holder for pressure sensor 073505 Holder for temperature and level sensor 073506 Holder for conductance sensor 073507 Holder for Liquiphant 073509 Holder for measuring sen...

Страница 9: ...f the process housing is integrated in a piping system in which the media can reach a temperature of more than 50 C the surface temperature can also reach this value Risk of scalding chemical burns If...

Страница 10: ...sert new greased O ring seal Re insert the blind or closing plate in the process housing ensure it is positioned correctly Tighten the grooved nut in clockwise direction Replacing the seal at the meas...

Страница 11: ...e necessary work keep strictly to the safety information Leakage at the closing plate Housing O ring seal defective Remove the blind or closing plate Replace the O ring seal Leakage at the measuring s...

Страница 12: ...ng plate 073506 for conductance transmitter art no 34310 Housing connection DN O ring seal O ring seal Sensor connection 073506 00050 50 65 105772 G 1 073506 00065 80 150 105725 Closing plate 073507 f...

Отзывы: