OPERATION
EMERGENCY SHUTDOWN
In case a foreign object becomes lodged in the expeller or
auger area, disengage the PTO. Stop the tractor engine,
remove ignition key, and allow all mechanisms to stop before
cleaning or working on the machine. If an object is lodged
inside the tank, block-up the discharge gate and raise the
conveyor auger before attempting to remove the object.
GENERAL INFORMATION
Check entire Top Shot carefully before first operation. Tighten bolts and set screws that might have come
loose in shipping. Lubricate as explained in the Lubrication Chapter in this manual.
H&S Top Shots feature a large tank, forward right side discharge expeller, hydraulically controlled
discharge gate, and conveyor auger. Top Shots are designed and constructed to handle a wide variety of
waste material types including liquids, semi-liquids, and limited solid material. Many potential spreading
problems can be avoided if the following guidelines are established and met:
NOTE:
To prevent damage to the expeller, auger, and drive line, foreign objects such as stones,
timber, or metal should never be placed into the Top Shot tank.
1. In winter or freezing temperatures, make sure the auger and expeller are free to rotate and that
the discharge gate moves freely, before loading the Top Shot and applying PTO power.
2. The discharge gate must be closed before loading.
3. The auger must be completely lowered before loading.
4. When loading packed material into the Top Shot with a loader bucket, try to break up any large
chunks.
5. Material which is too thick or solid to flow should only be heaped on the rear 2/3 of the Top Shot.
6. When hauling extremely heavy materials with a large portion of dirt, it may be necessary to reduce
the load size to prevent excessive shear bolt breakage. Do not use extra sideboards. Do not
overload the Top Shot. Overloading decreases spreading effectiveness.
7. Liquid or semi-liquids that flow will self-level allowing the Top Shot to be filled to a level such that
sloshing or splashing material will be contained.
NOTE:
Expeller feeding will diminish as bridging occurs. To counteract bridging, completely raise, and
lower the auger back down immediately. This operation will help to break-up the bridging.
-20-
Содержание Top Shot 5215
Страница 3: ... 1 ...
Страница 5: ... Remove Copy At Perforation 3 ...
Страница 6: ...Intentionally Left Blank 4 ...
Страница 8: ... 6 Intentionally Left Blank ...
Страница 10: ... 8 Intentionally Left Blank ...
Страница 13: ... 11 SAFETY INFORMATION ...
Страница 14: ...SAFETY INFORMATION 12 ...
Страница 16: ... 14 ...
Страница 38: ...DECAL LOCATION 36 111209C 71188B 71067 71064 093020 093366 DCAMB DCAMB 71067 111209C 71064 093020 DCAMB ...
Страница 40: ...DECAL LOCATION 38 9194A 82602 1494L 8515 82602 9194A 5896B 111209A 311 093020 ...
Страница 42: ...DECAL LOCATION 40 51010 111209B 11599 58703 093020 111209C 11599 DCRED DCRED 32320 TFM97 51010 71085 093020 ...
Страница 44: ...SERVICE NOTES 42 ...
Страница 45: ......
Страница 46: ...H S MFG CO products approved for the FEMA SEAL OF QUALITY ...