Controller Parameters 

 

Parameter 

Value 

Parameter 

SPL 

33° F 

Minimum temperature setpoint 

SPH 

40 F 

Maximun temperature setpoint 

SP 

33 F 

Effective setpoint 

C-H 

REF  

Operation mode:Refrigeration 

HYS 

Hysteresis (Differential) 

CRT 

Minimum compressor off time 

CT1 

Compressor run time if T1 failure 

CT2 

Compressor off time if T1 failure 

CSD 

Compressor stop delay door opening (active only if DS=Yes) 

DFM 

TIM 

Defrost start mode: Time interval 

DFT 

12 

Defrost interval 

DFB 

YES 

Defrost timer backup 

DLI 

45 

Defrost and temperature 

DTO 

50 

Maximum Defrost duration 

DTY 

OFF 

Defrost type (OFF cycle) 

DPD 

Evaporator pump down 

DRN 

Pause after Defrost 

DDM 

DEF 

Display during Defrost 

DDY 

10 

Display delay 

FID 

YES 

Fans active during Defrost 

FDD 

45° 

Evaporator fan re-star temperature after Defrost (refered to T2 probe) 

FTO 

Mximun evaporator fan stop after Defrost 

FCM 

NON 

Evap operation mode: Fan on continuosly 

FDT 

Evap air temperature difference for the fans to turn off after the compressor has stopped 

FDH 

Temperature differential for fan re-start 

FT1 

Fan stop delay 

FT2 

Timed fan stop 

FT3 

Timed fan run 

ATM 

NON 

Alarm threshold control 

ADO 

5m 

Delay before door open alarm warning 

AHM 

NON 

Operation in case of high condenser alarm 

ACC 

Condenser periodic cleaning 

IISM 

NON 

Switchover mode to second parameter set 

SB 

NO 

Stand by button enabling 

DI1 

NON 

Digital input operation 

DI2 

NON 

Digital input operation 

LSM 

NON 

Light control mode 

OA1 

Non 

AUX 1 output 

OA2 

FAN 

AUX 2 output: evap pan 

OS1 

-1 

Probe T1 offset 

T2 

YES 

Probe T2 enabling (evaporator) 

OS2 

Probe T2 offset 

TLD 

30 

Delay for minimun temperature (TLO) and maximun temperature (THI) logging 

SCL 

°F 

Read out scale 

SIM 

Display Slowdown 

ADR 

BIT25 address for PC communication 

RES 

NO 

Restore default program 

 

Содержание 87050.01P

Страница 1: ...loyees of McDonald s Systems Inc Manufactured by H K International 2200 Skyline Drive Mesquite TX 75149 U S A Telephone 214 818 3500 Fax 214 818 3596 Distributed by H K International 2200 Skyline Drive Mesquite TX 75149 U S A Telephone 214 818 3500 Fax 214 818 3596 30 2 DRAWER REFRIGERATOR Equipment Manual H K Model Number 87050 01P ...

Страница 2: ...ose Components 5 Wash and Sanitize Unit Interior Drawer Components 5 Operating Instructions 6 Temperature Setting 6 Operating Procedure 6 Loading and Restocking 7 Cleaning 7 Exterior Cleaning 7 Interior Cleaning 7 Preventative Maintenance 8 Clean the Condenser Coils Quarterly 8 Check Gasket Quarterly 8 Product Warranty 12 Troubleshooting 13 Assembly Drawing 15 Wiring Diagram 16 Refrigeration Speci...

Страница 3: ... to clean the unit will result in scratching and spoiling the finish of the unit Do not leave the drawers open for extended period of time CAUTION This unit contains a flammable refrigerant This Installation Operating Manual contains important instructions and safety information Read and understand the contents of this manual before attempting to install operate or service the unit Disconnect all ...

Страница 4: ...ght carrier and H K immediately Uncrate the Unit This unit will arrive crated in a skid mounted carton Cut the banding holding the cardboard carton to the shipping pallet using heavy scissors or tin snips Use caution to avoid contact with cut banding Lift the cardboard carton straight up and off the unit Cut the banding that holds the refrigerator to the shipping pallet or skid Use caution to avoi...

Страница 5: ...ed to secure the loose components Wash and Sanitize Unit Interior Drawer Components Wipe down sanitize and dry the refrigerator interior using McD Approved KAY Peroxide Multi Surface Cleaner Disinfectant Solution cleaner sanitizer OR McD Approved Sink Detergent Solution and Sanitizer Solution Note Use only McDonald s approved cleaning and sanitizing agents according to instructions ...

Страница 6: ... refrigerator is turned ON by 1 plugging the cord into a Wall outlet 2 Turn power switch located back left side of refrigerator to ON The evaporator fan will run immediately the compressor the condenser fan will run after 1 minute delay Let the unit run for 30 minutes before placing product in the refrigerator Temperature Setting The unit has been tested at the factory and the control has been pre...

Страница 7: ...Solution and Sanitizer Solution Do not use abrasive cleaners to clean the exterior of the cabinet as this might damage the stainless steel finish Do not use steel wool or any strong chemicals Interior Cleaning The Stainless Steel interior of the refrigerator can be cleaned using a soft sponge and McD Approved KAY Peroxide Multi Surface Cleaner Disinfectant Solution cleaner sanitizer OR McD Approve...

Страница 8: ... please call 1 800 521 3987 or visit hkionline com to order replacement gasket H 4 39 215 WARNING Verify refrigerator is disconnected from the power source before attempting any preventative maintenance Failure to disconnect the electric power could result in electric shock burns injuries or death Warning Failure to properly perform scheduled preventative maintenance may void manufacturer s warran...

Страница 9: ...pproved Kay Peroxide Multi Surface Cleaner and Disinfectant solution Please See PM Card for Cleaning Details To Remove Drawers 1 open drawer fully and press front drawer lock forward on both sides 2 Grasp both sides of drawer lift and pull drawer forward and out To Remove Drawer Roller assembly 1 To remove roller assembly press rear lock back as shown Then pull roller assembly out 2 Clean Roller a...

Страница 10: ...s on as Shown Push roller assembly To rear of channel to lock roller assembly into track 2 Please insure that front drawer lock Is in the unlocked forward position as shown in picture 3 Load drawer by grasping drawer on both sides Place rails on drawer body on front wheels of roller assembly as shown Roll drawer back into cabinet while slightly Lifting the front of the Drawer ...

Страница 11: ... s Systems Inc Page 11 of 18 Revision A Press front Locking tabs back to lock to insure Safe operation of the Drawer Now roll Drawer back and forth and verify smooth drawer slide operation Please Scan QR Code on front of cabinet to access video on to remove and install drawer ...

Страница 12: ... for expenses or repairs made by other parties except by written consent Corrections of such defects by repair or replacement shall constitute fulfillment of all company obligations to the purchaser H K shall not be liable for loss damages or expenses arising from misuse abuse alteration accident or improper installation of the refrigerator such as Improper or unauthorized repair Failure to follow...

Страница 13: ...rature of 33 F 1 C to 36 F 2 C Condenser Coil is dirty or clogged with debris Use a vacuum cleaner or soft brush to clean coils per Preventative Maintenance instructions If these steps do not fix problem Call H K at 800 788 2445 for service Drawer is left opened for extended periods Review product loading and general use instructions with crew to ensure drawer is open for restocking and order fill...

Страница 14: ...does not go back to normal operation after 1 hour Call H K at 800 788 2445 for service Controller read rec Unit is currently is in recovery after defrost If unit does not go back to normal operation after 1 hour Call H K at 800 788 2445 for service Gasket condition reference pictures Gasket in good condition Gasket broken Replace please Call H K at 800 521 3987 or Visit hkonline com to order repla...

Страница 15: ...This manual is for the exclusive use of licensees and employees of McDonald s Systems Inc Page 15 of 18 Revision A Assembly Drawing ...

Страница 16: ...This manual is for the exclusive use of licensees and employees of McDonald s Systems Inc Page 16 of 18 Revision A Wiring Diagram ...

Страница 17: ... 290 Operating pressure LSP 15 psig HSP 100 psig Electrical Data 120v 1ph 60hz MCA 2 0 MAX FUSE 15amps System charge 4 1 oz 116g Replacement Parts DESCRIPTION H K PART NO Compressor P 1 313 Capillary tube 8 Ft 2 43 m of P 1 56 1200 Dryer P 1 24 2 Controller G R02043 Power cord E 10 12 8 Evaporator Fan E 6 022 Condenser Fan E 6 023 Drawer Gasket H 4 39 215 ...

Страница 18: ...rost FDD 45 Evaporator fan re star temperature after Defrost refered to T2 probe FTO 0 Mximun evaporator fan stop after Defrost FCM NON Evap operation mode Fan on continuosly FDT 0 Evap air temperature difference for the fans to turn off after the compressor has stopped FDH 1 Temperature differential for fan re start FT1 0 Fan stop delay FT2 0 Timed fan stop FT3 3 Timed fan run ATM NON Alarm thres...

Отзывы: