Precaution when Using Mold
Some application require a special mold as fixture to position the object correctly, examples are
zipper mold or pocket mold. It is essential that the center of mold is position directly under the
center of the press, or otherwise the downward pressing force from the main cylinder may
induce a rotating force to the rotating head. This may cause damages to the press head and the
cylinder and may also affect the overlook of the product due to uneven pressure. In case the
mold is required to position off center, a counter balance mold of the same height is necessary
to correct the force of the press.
The following illustrations (top view) demonstrate the correct and incorrect method of using
mold.
Correct
(
1
)
(
2
)
(
3
)
1.
Zipper mold is positioned at the center of the working table.
2.
Zipper mold is positioned off centered, a counter mold is added at the right hand side of the
working table.
3.
Zipper mold is positioned off centered, a count mold is added at the left hand side to
balance the force
Incorrect
(
1
)
(
2
)
1. Missing left hand side counter mold
2. Missing right hand side counter mold
Missing near side
counter mold
Missing far side
counter mold
Counter mold
added
Counter mold
added
Содержание CS-653
Страница 4: ...CS 653 operation manual issue 1 14 02 19 P 3 of 19 Precautions with regard to Safety cont...
Страница 5: ...CS 653 operation manual issue 1 14 02 19 P 4 of 19 Name Plate...
Страница 19: ...CS 653 operation manual issue 1 14 02 19 P 18 of 19 Appendix A Pneumatic Scheme...
Страница 20: ...CS 653 operation manual issue 1 14 02 19 P 19 of 19 Appendix B Wiring Scheme...