3 - 17
Auxiliary Port Input Communications
Data Character Selection
This selection selects the serial output data characters that may be sent from the
RS-232 device connected to the Auxiliary Port.
When the Aux Port is used as an input, it is recommended (although not
required) that incoming messages be “framed” by start and stop characters.
These framing characters indicate to the base the beginning and end of a
message. The use of these characters decreases the possibility of missing or
partial messages being sent to the host system.
Note: These characters are stripped from the message within the base and are
not sent to the host system.
The bar codes below are used to configure the base to conform to the specific
framing characters sent from the peripheral device.
• SOR -- used to program the starting frame character of a “record”
• EOR -- used to program the ending frame character of a “record”
• SOB -- used to program the starting frame character of a “block”
• EOB -- used to program the ending frame character of a “block”
Default SOR Character = none (NUL: 00).
Default EOR Character = Carriage Return (CR: 0D).
Default SOB Character = none (NUL: 00).
Default EOB Character = End of Text (EOT: 04).
1. A two-digit number and Save are required after scanning this programming bar code.
Refer to the Programming Chart (inside back cover).
SOR (Start of Record)
1
EOR (End of Record)
1
EOB (End of Block)
1
SOB (Start of Block)
1
Содержание SCANTEAM 2070
Страница 10: ......
Страница 20: ...x...
Страница 44: ...1 24...
Страница 62: ...2 18...
Страница 102: ...4 12...
Страница 108: ...5 6 Initiate Key Macro IT3875 and ST2070 5 only FN 0 FN 1 FN 2 FN 3 FN 4 FN 5 FN 6 FN 7 FN 8 FN 9 Asterisk Macro...
Страница 130: ...5 28...
Страница 132: ...6 2 Codabar Default All Codabar Settings Codabar Start Stop Characters On Off Transmit Don t Transmit...
Страница 136: ...6 6 Code 39 Default All Code 39 Settings Code 39 Start Stop Characters On Off Transmit Don t Transmit...
Страница 141: ...6 11 Code 93 Default All Code 93 Settings Code 93 On Off...
Страница 143: ...6 13 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off...
Страница 146: ...6 16 Code 2 of 5 Default All Code 2 of 5 Settings Code 2 of 5 On Off...
Страница 148: ...6 18 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off...
Страница 150: ...6 20 Code 11 Default All Code 11 Settings Code 11 Code 11 Check Digits Required On Off 2 Check Digits 1 Check Digit...
Страница 152: ...6 22 Code 128 Default All Code 128 Settings Code 128 On Off...
Страница 155: ...6 25 Telepen Default All Telepen Settings Telepen On Off...
Страница 157: ...6 27 China Post Code IT3870 IT3875 only Default All China Post Code Settings China Post Code On Off...
Страница 161: ...6 31 PDF417 IT3870PDF IT3875PDF only Default All PDF417 Settings PDF417 On Off...
Страница 166: ...6 36 MicroPDF417 IT3870PDF IT3875PDF only Default All MicroPDF417 Settings MicroPDF417 On Off...
Страница 170: ...6 40 EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 EAN JAN8 Check Digit On Off Transmit Don t Transmit...
Страница 173: ...6 43 UPC A continued UPC A Check Digit Number System Transmit Don t Transmit Transmit Don t Transmit...
Страница 177: ...6 47 UPC Addenda Two Digit Addenda On Two Digit Addenda Off Five Digit Addenda On Five Digit Addenda Off...
Страница 178: ...6 48...
Страница 182: ...7 4...
Страница 188: ...8 6...
Страница 199: ...9 11 Cordless Base Dimensions ST2070 Front View 1 4 in 3 6 cm Top View 4 5 in 11 5 cm 4 0 in 10 2 cm 3 4 View Side View...
Страница 217: ...11 5 Limited Warranty Durations IT3870 3875 ST5770 ST2070 CLESS NIMH S Charge Pack 3 Years 3 Years 3 Years 1 Year...
Страница 218: ...11 6...
Страница 226: ...12 8...
Страница 227: ......
Страница 231: ...Programming Chart A C Save B Discard Current Changes F E D...
Страница 232: ...3870 75 5770 SM Rev C...