3 - 11
41
start character match for Code 39, 41h = “A”
FF
termination string for first code
6A
code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42
start character match for Code 128, 42h = “B”
FF
termination string for second code
69
code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths
43
start character match for Code 93, 43h = “C”
FF
termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-10, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62
code identifier for Code 39
0012
A - Code 39 sample length (11) plus CR suffix (1) = 12
41
start character match for Code 39, 41h = “A”
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = “B”
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = “C”
FF
termination string for third code
Содержание 3820
Страница 1: ...2020 3820 Cordless System User s Guide...
Страница 7: ...Required Safety Labels 3820SR0C0BE 3820...
Страница 62: ...2 18 2020 3820 User s Guide...
Страница 86: ...5 6 2020 3820 User s Guide...
Страница 132: ...8 4 2020 3820 User s Guide...
Страница 162: ...11 8 2020 3820 User s Guide...
Страница 175: ......
Страница 176: ......
Страница 180: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3820 UG Rev A 5 06...