13 - 2
3800i/3800r User’s Guide
Replacing the Interface Cable
The standard interface cable is attached to the scanner with an 10-pin modular
connector. When properly seated, the connector is held in the 3800i/3800r
scanner’s handle by a flexible retention tab. The interface cable is designed to
be field replaceable.
•
Order replacement cables from Hand Held Products or from an authorized
distributor.
•
When ordering a replacement cable, specify the cable part number of the
original interface cable.
To Replace the 3800r Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the scanner’s cable from
the terminal or computer.
3. Locate the small hole on the side of
the scanner’s handle (3800i/3800r).
This is the cable release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing
the connector. Pull the connector out
while maintaining pressure on the
paper clip, then remove the paper clip.
6. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will click into place.
Cable
Release
Содержание 3800ISR050-0F00E
Страница 1: ... 3800i Industrial Handheld Linear Imager 3800r Retail Commercial Handheld Linear Imager User s Guide ...
Страница 6: ......
Страница 18: ...1 4 3800i 3800r User s Guide 3800i 3800r Scanner Identification ...
Страница 19: ...3800i 3800r User s Guide 1 5 3800i Scanner with aimer beam option Identification ...
Страница 30: ...1 16 3800i 3800r User s Guide ...
Страница 70: ...5 6 3800i 3800r User s Guide ...
Страница 76: ...6 6 3800i 3800r User s Guide ...
Страница 112: ...7 36 3800i 3800r User s Guide ...
Страница 140: ...11 18 3800i 3800r User s Guide ...
Страница 150: ...12 10 3800i 3800r User s Guide ...
Страница 158: ...14 4 3800i 3800r User s Guide ...
Страница 163: ......
Страница 164: ......
Страница 168: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3800i r UG Rev A 5 06 ...