HANCHU ESS HOME-ESS-LV-2.56K Скачать руководство пользователя страница 7

HOME-ESS-LV-2.56K

Smart Energy, Sustainable Solutions

4

Professionals: personnel who are trained or experienced in equipment operations and are clear of the
sources and degree of various potential hazards in equipment installation, operation and maintenance.

Trained personnel: personnel who are technically trained, have required experience, are aware of
possible hazards on themselves in certain operations and are able to take protective measures to
minimize the hazards on themselves and other people.

Operators: operation personnel who may come into contact with the equipment,except trained
personnel and professionals.

The installation and operating environment must comply with international, national and local

standards for lithium batteries and with local laws and regulations.

Install in a location out of the reach of children.

Garage installation needs to be far away from the direction of vehicle travel, it is recommended to install

the energy storage on the wall above the body bumper to avoid an accidental collision.

When installing the battery in a basement, keep good ventilation. Do not place flammable or explosive

materials around the battery. It is recommended that the battery be mounted on the wall to avoid contacting
with water.

Install the battery in a dry and well-ventilated environment. Secure the battery on a solid and flat

surface.

Install the battery in a sheltered place or install an awning over it to avoid direct sunlight or rain.

Install the battery in a clean environment that is free from sources of strong infrared radiation, organic

solvents, and corrosive gases.

Precautions should be taken for installation in areas with frequent natural disasters such as floods,

mudslides, earthquakes and typhoons.

Keep the battery away from fire sources. Do not place any flammable or explosive materials around the

battery.

Keep the battery away from water sources such as taps, sewer pipes, and sprinklers to prevent water

seepage.

Do not install the battery in a position where it is easy to touch as the temperature of the chassis and

heat sink is high when the battery is running.

To prevent fire due to high temperature, ensure that the vents and the cooling system are not blocked

when the battery is running.

Do not expose the battery to flammable, explosive gas or smoke. Do not perform any operation on the

battery in such an environment.

Do not install the battery on a moving object, such as ship, train or car.

Do not install the system outdoors in a salt-affected area because the system may be corroded. A salt-

affected area is an area within 500m from the coast or affected by sea breeze. The area affected by the sea
breeze varies according to meteorological conditions (such as typhoons and seasonal winds) or
topographical conditions (such as DAMS and hills).

2.3 Installation Environment Requirements

Содержание HOME-ESS-LV-2.56K

Страница 1: ......

Страница 2: ...osal of the products shall be carried out in accordance with the user manual relevant contract or relevant laws and regulations The products services or features you purchase are subject to the commer...

Страница 3: ...2 9 EU Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Interface Description 11 3 3 Product Parameters 12 4 Installation 13 4 1 Installation Note 13 4 2 Installati...

Страница 4: ...ce etc Unauthorized changes or modifications to the product are not permitted any unauthorized changes will void the HOME ESS LV 2 56K warranty and Hanchu ESS will not be liable for any damages caused...

Страница 5: ...the battery outside the scenarios specified by us including but not limited to connecting of excess loads mixing with batteries with different rated capacities or with other batteries Damage to the b...

Страница 6: ...quipment Measure the voltage before touching conductor surface or terminal to verify that there is no risk of electric shock Repair the scratches that occur during equipment transportation and install...

Страница 7: ...ure the battery on a solid and flat surface Install the battery in a sheltered place or install an awning over it to avoid direct sunlight or rain Install the battery in a clean environment that is fr...

Страница 8: ...nts or areas This prevents damage of the insulation layer of the cables When the temperature is low violent impact or vibration may damage the plastic cable sheathing To ensure safety comply with the...

Страница 9: ...tedly grounded Please remove power from the ground if accidental grounding occurs 2 6 Battery Safety Do not expose batteries at high temperatures or around heat generating sources such as sunlight fir...

Страница 10: ...arking The system complies with the requirements of the applicable EU directives Observe the documents Observe all documents supplied with the system Disposal Do not dispose of the system together wit...

Страница 11: ...tective clothing Electrolyte is corrosive and can cause irritation and chemical burns In case of direct contact with the battery electrolyte do as follows Inhalation Evacuate contaminated areas get fr...

Страница 12: ...p away from the batteries to avoid skin irritation and chemical burns Dispose of used batteries in accordance with local laws and regulations Do not dispose of batteries as household waste If the batt...

Страница 13: ...utput current of the inverter connected to the battery exceeds 100 A please use it in conjunction with the Hanchu combiner box 3 1 Product Description 3 1 1 System Composition The battery system consi...

Страница 14: ...ainable Solutions 11 3 1 3 Product Dimension And Weight Table 3 Product Dimension And Weight Width Depth Height Weight 340mm 160mm 340mm 24 5kg Figure 2 Picture of the Product 3 2 Interface Descriptio...

Страница 15: ...54 4 Module configuration 1 parallel 16 strings 1P16S 5 Nominal voltage V 25 6 6 Operating voltage range V 21 6 28 8 7 Nominal Energy Wh 2560 8 Nominal discharge current A 100 9 Max discharge current...

Страница 16: ...or the injured Complying with local laws regulations standards and directives 4 1 2 Installation Environment Please make sure the installation location meets the following conditions The building is d...

Страница 17: ...on a flat wall and keep the battery parallel to the wall And don t install the battery at inclined horizontal or upside down positions Figure 5 Installation Angle 4 1 4 Installation Space Leave enoug...

Страница 18: ...e the module is accidentally dropped during installation Figure 7 Personal Protective Equipment 4 2 2 Installation Tools Tools needed in the process of installing equipment more effective to improve i...

Страница 19: ...nect the negative pole between the battery and the inverter E Power cable 4 SC35 8 at both ends red 1000mm 1 Connect the positive pole between the battery and the inverter F RS485 communication line 8...

Страница 20: ...holes on the wall Use the bracket as a template to make positioning holes in the wall mark the positions of the 6 holes and then drill 10mm holes to ensure that the depth of the holes is greater than...

Страница 21: ...ositioning groove of the wall bracket for firm support Figure 11 Sample of Step 3 For Wall Installation 4 4 Electrical Connections Before connecting the cables use a multimeter to measure cable contin...

Страница 22: ...oduct 5 Power cable 4 Connect the positive pole between the battery and the inverter Red 1000mm Delivered with the product 6 RS485 communication line Connect the communication interface between batter...

Страница 23: ...e 15 Sample of Power Connections Between Batteries 4 4 5 Connect The Primary Battery with The Inverter through Power Cord After the battery is connected according to Step 1 2 connect the negative pole...

Страница 24: ...er with the primary through CAN protocol Figure 17 Sample of Connection the CAN Communication Cable 4 5 2 Connect the RS485 Communication Cable Use the RS485 communication cable to connect the battery...

Страница 25: ...connecting the primary to the inverter are defined as follows Table 7 Definition of CAN Port Pins CAN INVERTER Port RJ45 Pins Definition 1 8 RS485A B 2 7 RS485A A 3 NC 4 CANH1 5 CANL1 6 GNDC 3 The co...

Страница 26: ...witch in turn first the primary 01 then the sub 02 16 to start the battery 2 Observe whether the status of the indicator light on the battery panel is normal RUN green light flash ALM light off Indica...

Страница 27: ...ollowing table Table 10 DIP Switch Settings for CAN Communication CAN Communication Primary unit DIP ON DIP OFF Inverter brands 2 1 HanchuESS Luxpower 1 2 Pylon Deye 1 2 Victron SMA Inverter brands us...

Страница 28: ...he fifth ALM light Red light is a fault indicator which will light up when the system has a fat The sixth RUN light is the normal operation light and the green light will light up when the system is o...

Страница 29: ...rature protection According to the battery indicator ON OFF Discharge Normal According to the battery indicator OFF FLASH 3 Alert According to the battery indicator FLASH 2 FLASH 3 Undervoltage protec...

Страница 30: ...n lost between batteries 1 Move the DIP switch to the correct position 2 Check if the communication cable between the batteries is correct and well connected Over Voltage Alarm Battery voltage is too...

Страница 31: ...voltage sensor failure Please contact Hanchu ESS after sales service company or your dealer directly TempSensor Fault Battery temperature sensor failure Please contact Hanchu ESS after sales service...

Страница 32: ...rage temperature an irreversible capacity loss of lithium batteries is 3 10 The batteries should be stored in accordance with the labels on the packaging box and should not be inverted or placed sidew...

Страница 33: ...ot provide appropriate warranty service for permanent battery failure due to improper storage by the customer 6 4 Battery Maintenance Safety Requirements When the equipment is running a high voltage m...

Страница 34: ...d required precautions Please use the same type of cell when replacing cells After maintenance immediately check that no tools or other parts have been left inside the equipment If the equipment has n...

Страница 35: ...32...

Отзывы: