4.6.4 Equipment Power Down
After confirming that the load is off and the battery has stopped charging and discharging, power down in
the following order:
1) Disconnect the circuit breaker on the battery and the circuit breaker between the battery and the inverter.
2) Turn off the power switch on the battery.
3) Indicator light goes out.
If the battery is not working after a long period of time, it is necessary to maintain and recharge the battery
in time according to subsections 6.2 and 6.3 of this manual.
4.7 Definition of Indicator Lights
The indicator light consists of 6 lights, the first 4 lights indicate the SOC of the battery, which are 25%, 50%,
75% and 100% respectively. The fifth ‘ALM’ light (Red light) is a fault indicator, which will light up when the
system has a fat. The sixth ‘RUN’ light is the normal operation light, and the green light will light up when the
system is operating normally. When the system shuts down, all lights go out.
4.7.1 Capacity Indicator
The definitions of the indicator lights during the charging and discharging process of the battery are shown
in the following table.
Table 12 Definition of the Indicator Lights
State
Charge
Discharge
capacity indicator
L1●
L2●
L3●
L4●
L1●
L2●
L3●
L4●
0
~
25%
FLASH 2
OFF
OFF
OFF
ON
OFF
OFF
OFF
25
~
50%
ON
FLASH 2
OFF
OFF
ON
ON
OFF
OFF
50
~
75%
ON
ON
FLASH 2
OFF
ON
ON
ON
OFF
75
~
100%
ON
ON
ON
FLASH 2
ON
ON
ON
ON
Running lights
ON
FLASH 3
4.7.2 Status Indicator
Table 13 Definition of the Status Indicator
State
Abnormal event
LED
ALM
RUN
●
●
●
●
●
●
Shutdown
Shutdown
ALL OFF
OFF
OFF
Standby
Normal
According to the battery indicator
OFF
FLASH 1
Alert
FLASH 2
FLASH 1