background image

Safety Rules ........................................1

Unpacking Your Fan ..........................2

Installing Your Fan ............................3

Operating Your Fan ...........................11

Operating Your Remote Control ......12

Care of Your Fan ................................14

Troubleshooting ..................................14

Specifications ......................................15

Warranty Information .......................16

1. 

To reduce the risk of electric shock, insure electricity 

has been turned off at the circuit breaker or fuse box 

before beginning.

2. 

All wiring must be in accordance with the National 

Electrical Code ANSI/NFPA 70-1999 and local electrical 

codes. Electrical installation should be performed by a 

qualified licensed electrician.

3. 

WARNING:  To  reduce  the  risk  of  fire  or  electric  shock, 

this fan should only be used with fan speed control part no. 

UC7058RYK, manufactured by Rhine Electronic Co., Ltd. 

or part no.: FAN-10R, manufactured by Chia Wei Electric 

Co., Ltd.

4. 

WARNING: To reduce the risk of shock, this fan must be 

installed with an isolation wall control/switch.

5. 

CAUTION: To reduce the risk of personal injury, use only 

the screws provided with the outlet box. 

6. 

The outlet box and support structure must be securely 

mounted and capable of reliably supporting a minimum of 

35 pounds. Use only UL Listed outlet boxes marked “FOR 

FAN SUPPORT.”

7. 

The fan must be mounted with a minimum of 7 feet  

clearance from the trailing edge of the blades to the floor.

8. 

Do not wait for the fan to stop to press the reverse button. 

The fan will not reverse if the fan is not moving.

9. 

Avoid placing objects in path of the blades.

10. 

To avoid personal injury or damage to the fan and 

other items, be cautious when working around or 

cleaning the fan.

11. 

Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be 

suitable for most cleaning. 

12. 

After making electrical connections, spliced conductors 

should be turned upward and pushed carefully up into 

outlet box. The wires should be spread apart with the 

grounded conductor and the equipment-grounding 

conductor on one side of the outlet box.

13. 

Electrical diagrams are for reference only. Light kits that are 

not packed with the fan must be UL Listed and marked suit-

able for use with the model fan you are installing. 

14. 

WARNING: To reduce risk of fire or electric shock, do not 

use this fan with any solid-state speed control device.

15. 

All set screws must be checked and retightened where nec-

essary before installation.

 Safety Rules 1.

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT TO OUTLET BOX MARKED “ACCEPTABLE FOR 

FAN SUPPORT OF 35LBS (15.9KG) OR LESS” AND USE MOUNTING  

SCREWS PROVIDED WITH THE OUTLET BOX. OUTLET BOXES COM-

MONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT 

ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. 

CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE 

BLADE BRACKETS (ALSO REFERRED TO AS (“FLANGES”) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

Содержание Windward II

Страница 1: ...se fol pantone guide for actual color when printing This line is for die cut position only DO NOT PRINT IT V1 3 09 07 29 V0 0 17 Apr 09 V0 0 17 Apr 09 V0 0 17 Apr 09 V0 0 17 Apr 09 V0 0 17 Apr 09 V0 0...

Страница 2: ...ce your SKU 523 342 white 523 127 brushed steel or UPC 082392 552961 white 082392 552954 brushed steel Thank you for purchasing this Hampton Bay ceiling fan This product has been manufactured with the...

Страница 3: ...an and other items be cautious when working around or cleaning the fan 11 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable...

Страница 4: ...de On Mounting Plate inside Canopy 2 Downrod and Ball Assembly 3 Canopy with Canopy Ring Attached 4 Decorative Motor Collar Cover 5 Fan Motor Assembly 6 Light Kit Fitter Assembly 2 Unpacking Your Fan...

Страница 5: ...ger downrod to maintain proper blade clearance when install ing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches downrod remove the decorative canopy bottom cover and...

Страница 6: ...tance from the ceiling to the bottom of the fan blades to approximately 8 inches Once you have decided which ceiling installation you will use proceed with the following instructions Where necessary e...

Страница 7: ...e canopy ring from the canopy by turning the ring to the right until it unlocks Figure 5 2 Remove the mounting plate from the canopy by loosening the four screws on the top of the canopy Remove the tw...

Страница 8: ...test Make sure the dip switches setting in the transmitter match the receiver When two or more fans are located near each other you may want to have each set to a different frequency so that operation...

Страница 9: ...ly up to the ceil ing mounting plate If using close to ceil ing mounting hang the fan on the hook provided by utilizing one of the holes at the outer rim of the ceiling canopy Fig ure 12 If using stan...

Страница 10: ...re Step 3 Connect the two green fan ground wires located on the downrod and mounting bracket to the household ground wire When using Close to Ceiling mounting there is only one green ground wire from...

Страница 11: ...ch screw securely CLOSE TO CEILING MOUNTING 1 Carefully unhook the fan from the mount ing plate and align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to e...

Страница 12: ...he blades are weight matched The following procedure should correct most fan wobble Check after each step 1 Check that all blade and blade bracket screws are secure 2 Most fan wobble problems are caus...

Страница 13: ...ing effect as shown in Figure 17 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling a...

Страница 14: ...an speed is automatically set on High Med or Low speed depending upon the room tem perature and the user selected temperature set point Press the Temp Set Up and Down but tons to select the desired ro...

Страница 15: ...To select C F press these two buttons at the same time and hold for 3 seconds or use a ballpoint pen or small screwdriver to press the hole in the back of the transmitter 13...

Страница 16: ...ECTION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the s...

Страница 17: ...EIGHT GROSS WEIGHT CUBE FEET 54 Low 120 2546 11 231 23 8 Lbs 26 9 Lbs 2 6 Med 120 4527 31 146 High 120 7506 72 105 Specifications 15 These are approximate measures They do not include Amps and Wattage...

Страница 18: ...be considered a defect Servicing performed by un authorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including b...

Страница 19: ...cia el N de SKU 523 342 blanco 523 127 acero cepillado o UPC 082392 552961 blanco 082392 552954 acero cepillado Gracias por comprar este ventilador de techo de Hampton Bay Este producto se ha fabricad...

Страница 20: ...en cuidado al trabajar cerca del ventilador o al limpiarlo 11 No usar agua o detergentes para limpiar el ventilador o las aspas En general a la hora de limpiar bastar con usar un pa o seco o ligeramen...

Страница 21: ...lizable dentro de la cubierta 2 Ensamblado de tubo bajante y bola 3 Cubierta con aro incorporado 4 Cubierta decorativa del collar n del motor 5 Ensamblado del motor del ventilador 6 Ensamblado del sop...

Страница 22: ...ima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 30 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubi e...

Страница 23: ...aspas a 8 pulgadas aproxima damente Una vez elegido el tipo de instalaci n sigue con las siguientes instrucciones Cuando sea necesario cada secci n de las instrucciones indicar los diferentes procedim...

Страница 24: ...montaje de la cubierta aflojando los cuatro tornillos de la parte su perior de la misma Quita los dos tornillos sin ranura y afloja los tornillos ranurados Esto te permitir retirar la placa de montaje...

Страница 25: ...ecta la corriente y prueba Aseg rate de que la configuraci n de los interruptores en l nea del transmisor coincide con el receptor Cuando dos o m s ventiladores est n ubicados cerca el uno del otro es...

Страница 26: ...usas el montaje cerca del techo cuelga el ventilador del gancho suministrado usando uno de los orificios en el borde exterior de la cubierta de techo Figura 12 CUANDO MONTES EL VENTILADOR EN UN TECHO...

Страница 27: ...necta los dos cables verdes de conexi n a tierra del ventilador ubicados en el tubo bajante y el soporte de montaje al cable de conexi n a tierra de la casa Cuando uses el montaje cerca del techo exis...

Страница 28: ...tornillos de manera firme MONTAJE CERCA DEL TECHO 1 Con cuidado desengancha el ventilador de la placa de montaje y alinea las ranuras de cierre de la cubierta del techo con los dos tornillos de la pl...

Страница 29: ...EMASIADO AL INSTALAR LA PANTALLA DE VIDRIO EN EL ENSAMBLAJE DEL KIT DE LUCES DEJA ENFRIAR COMPLE TAMENTE LA PANTALLA DE VIDRIO ANTES DE RETIRARLA Figura 16 Figura 15 l mpara circular MAX 30W incluida...

Страница 30: ...cante como se muestra en la figura 17 Esto te permite fijar tu aire acondicionado en una configuraci n m s alta sin afectar tu comodidad Clima fresco Reversa Un flujo de aire hacia arriba mueve el ai...

Страница 31: ...co En este modo la velocidad del ventila dor se configura autom ticamente en velocidad Alta Media o Baja dependiendo de la temperatura de la habitaci n y de la configu raci n de temperatura selecciona...

Страница 32: ...Para cambiar entre C F oprime al mismo tiempo estos dos botones por 3 segundos O usa un bol grafo o un destornillador peque o para oprimir el orificio en la parte trasera del transmisor 13...

Страница 33: ...o disyuntores principales y secundarios 2 Verifica conexiones de cables en l nea al ventilador y conexiones de cables del interruptor en la caja de interruptores PRECAUCI N Aseg rate de que est desact...

Страница 34: ...PIES C B X MIN VATIOS PESO NETO PESO BRUTO PIES C B 54 Baja 120 2546 11 231 23 8 Lb 26 9 Lb 2 6 Media 120 4527 31 146 Alta 120 7506 72 105 15 Especificaciones Estas medidas son aproximadas No incluyen...

Страница 35: ...es clim ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra garant a expre...

Отзывы: