                         1 

 

Use and Care Guide 

LED MOTION SENSOR  

PATH LIGHTS 

 

 

 

PACKAGE CONTENTS 

                                                                                                                                                                                                         

                                                           

 

 

 
 

                                        

   A –Lamp body  x 1                                      B – Wire Connector(with 12 in. wire attached to lamp body)                  C –Ground Stake (6.53 in.) x1 

 

Per assembly and Installation 

 

 

 

1

 

 

Detect PIR deck lights pairing 

Preliminary motion sensor and pairing test 

 

 

-

 If operating only one fixture, place the fixture in its permanent location.  

- To operate multiple fixtures, please pair the fixtures before installation, 

follow the PAIR steps below 

 

 

Lift the plastic cover (1) by hand, and then slided the swith (2) to the 

PIR. 

 

There is a DIP switch on the top of fixture, there have 4 bottons on the 
switch can be slided to up and down. The fixtures with the switch 
bottons in the exactly same setting will be paired as a group . Groups 
can be set freely (except "0000" and "1111"). 

 

When at PIR off mode (0000), fixture is at off status, will not pair.  

 

When at PIR test mode (1111), fixture will turn on after detecting 

motion whenever at day or night, then turn off after 3S of delay.  

 

If pairing lost efficacy, slided the swith (2) to the OFF, and then slided 

to PIR again. 

 

 

What to know before intall

:  

–Decide which PIR Deck Lights will be grouped (up to 10 fixtures). 
–Open the plastic cover on back of each PIR Deck Light.  

–Refer to the “Pairing via DIP Switch’’ Step to pair the deck lights. 
–Close the plastic cover (to prevent water go inside fixture). 

–When the gear is adjusted to "ON", it is "1"

 

 

 

Test the motion sensor function of a single deck light.

 

 

Connect path light into main power cord by wire connectors. 

 

Stir 4 buttons up to “ON” (Mode 1111) to make deck light on 
test mode. 

 

Cover the PIR sensor with light blocking object, to do 

preliminary function test. 

 

Remove the light blocking object, this path light will be 
powered on, this means that the single path light pairing 

function works. 

 
 

Test the pairing function of multiple deck lights. 

 

Connect each path light into main power cord by wire 

connectors (up to 10 deck lights). 

 

Stir 4 buttons in any mode (except "0000" and "1111"), which 
makes the path light enter the multi-lamp pairing test mode. 

 

The mode of all path lights that need to be paired needs to be 
set to the same. 

 

Cover the PIR sensor with light blocking object to each path 

lights to do preliminary function test. 

 

Remove the light blocking object of one path light, this path 
lights will be powered on. The rest of path lights in a group will 
be sequentially powered on. This means function of motion 
sensor and wirelessly link of path lights works. 
 

 

 

General Notes

:  

–When the transformer is turned off the fixture light will turn 

off, then PIR function become active and converts to battery 
power. 

–PIR Function is only active after the sensor detects the 
environmental brightness at less than 50LUX at night.  

–When the sensor detects the environmental brightness of less 
than 50LUX, plus PIR detects motion, the deck light will turn on 

and stay on for 1 minute before turning off. 
–When the sensor detects the environmental brightness higher 

than 200LUX, after a 90 second delay time, deck light will turn 
off.  The purpose of setting 90 second delay is to prevent the 
200LUX brightness caused by a flash of lightning or car light.  

 

Item # 1007 891 901 

Model # KXX1501LX-01 

 

Содержание KXX1501LX-01

Страница 1: ...re connectors Stir 4 buttons up to ON Mode 1111 to make deck light on test mode Cover the PIR sensor with light blocking object to do preliminary function test Remove the light blocking object this pa...

Страница 2: ...not touch the metal contacts CAUTION The wire from low voltage power unit should be 12 16 AWG type underground low Energy Circuit Cable IMPORTANT Protect the wiring by routing it in close proximity to...

Страница 3: ...power tools on the same electrical circuit may cause oscillations on the electrical line which might cause the fixture to malfunction NOTE In order to preserve battery life the minimum working temper...

Страница 4: ...4 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not Recommended 181 240 Watts 14 AWG 12 AWG Not Recommended 241 300 Watts 12 AWG Not Recommended Not Recommended 600W Transformer 2x300 Watts 12 AWG Not Recomm...

Страница 5: ...a luz de cubierta se encienda en el modo de prueba Cubra el sensor PIR con un objeto sombreado y realice una prueba funcional preliminar Al eliminar el objeto sombreado la luz de la trayectoria se ene...

Страница 6: ...cipal de bajo voltaje No toque los contactos de metal para evitar lesiones PRECAUCI N El cable de la unidad de bajo voltaje debe ser un cable subterr neo de circuito de baja corriente tipo 12 16 AWG I...

Страница 7: ...as herramientas el ctricas en el mismo circuito el ctrico pueden causar oscilaciones en la l nea el ctrica que pueden causar un mal funcionamiento del dispositivo Limpia la l mpara con un pa o suave y...

Страница 8: ...AWG 12 AWG No Recomendado 181 240 Watts 14 AWG 12 AWG No Recomendado 241 300 Watts 12 AWG No Recomendado No Recomendado 600W transformador 2x300 Watts 12 AWG No Recomendado No Recomendado 900W transfo...

Страница 9: ...dealer or an experienced radio TV technician for help Advertencia de la FCC Advertencia los cambios o modificaciones de esta unidad que no est n expresamente aprobados por la parte responsable del cu...

Отзывы: