The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of five (5) years from date of purchase. 
This warranty applies only to the original consumer and only to products used in normal use and service. If this product is found to be defective, the 
manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s discretion, provided that the 
product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect or mishandling. 

WHAT IS NOT COVERED 

This warranty shall not apply to any product that is found to have been improperly installed, set-up, or used in any way not in accordance with the 
instructions supplied with the product. This warranty shall not apply to a failure of the product as a result of an accident, misuse, abuse, negligence, 
alteration, or faulty installation, or any other failure not relating to faulty material or workmanship. This warranty shall not apply to the finish on any portion 
of the product, such as surface and/or weathering, as this is considered normal wear and tear. 

The manufacturer does not warrant and specifically disclaims any warranty, whether express or implied, of fitness for a particular purpose, other than the 
warranty contained herein. The manufacturer specifically disclaims any liability and shall not be liable for any consequential or incidental loss or damage, 
including but not limited to any labor / expense costs involved in the replacement or repair of said product. 

Contact the Customer Service Team at 1-855-HD-HAMPTON or visit HAMPTONBAY.COM 

 

12 VOLT TAP 

  

Cable Length 

  

Total Fixture Wattage 

0-50 feet 

51-100 feet 

101-150 feet 

0-60 Watts 

16 AWG 

16 AWG 

14 AWG 

61-120 Watts 

16 AWG 

14 AWG 

12 AWG 

121-180 Watts 

14 AWG 

12 AWG 

Not Recommended 

181-240 Watts 

14 AWG 

12 AWG 

Not Recommended 

241-300 Watts 

12 AWG 

Not Recommended 

Not Recommended 

600W Transformer 

= (2x300) Watts 

12 AWG 

Not Recommended 

Not Recommended 

900W Transformer

 = (3x300) Watts 

12 AWG 

Not Recommended 

Not Recommended 

 

 

 

 

15 VOLT TAP 

  

Cable Length 

  

Total Fixture Wattage 

0-50 feet 

51-100 feet 

101-150 feet 

0-60 Watts 

16 AWG* 

16 AWG 

16 AWG 

61-120 Watts 

16 AWG* 

16 AWG 

12 AWG 

121-180 Watts 

14 AWG* 

14 AWG 

12 AWG 

181-240 Watts 

14 AWG* 

14 AWG 

12 AWG 

241-300 Watts 

12 AWG* 

12 AWG 

Not Recommended 

600W Transformer 

= (2x300) Watts 

12 AWG* 

12 AWG 

Not Recommended 

900W Transformer

 = (3x300) Watts 

12 AWG* 

12 AWG 

Not Recommended 

* NOT RECOMMENDED FOR HALOGEN LANDSCAPE LIGHTS 

 

 

This data is provided as a general guideline. Actual performance will depend on the installation layout, the fixtures, and the condition of the cable. 

 

 

NOTE

: Most LED landscape lighting fixtures can operate with full illumination from 9V down to as little as 6V. It is possible to have extended 

length runs with LED fixtures that go beyond the specifications shown in the guidelines above.

 

 

Troubleshooting 

 

Problem 

Possible Cause 

Solution 

The fixture will 
not light. 

□ 

There is no power. 

□ 

There is a disconnection or 

break in the wire. 

□ 

The transformer setting is 

incorrect. 

□ 

Check the outlet and ensure that a breaker or GFCI circuit has not been tripped. 

□ 

Follow the wires from the fixture and ensure a continuous connected path back to the 

transformer. 

□ 

Check the settings on the transformer. 

The light flickers 
(one fixture). 

□ 

There is a loose wire 

connector to the fixture. 

□ 

Tighten the wire connector and ensure the metal contacts pierce the insulation on the low 

voltage cable from the transformer. 

The lights flicker 

(all fixtures). 

□ 

There is a loose connection at 

the transformer. 

□ 

Unplug the transformer from the outlet and visually inspect the positive and negative 

connecting points. Each wire should be securely screwed in and not in contact with any 
other. 

Warranty 

Cable Selection 

Содержание KXX1501LX-01

Страница 1: ...re connectors Stir 4 buttons up to ON Mode 1111 to make deck light on test mode Cover the PIR sensor with light blocking object to do preliminary function test Remove the light blocking object this pa...

Страница 2: ...not touch the metal contacts CAUTION The wire from low voltage power unit should be 12 16 AWG type underground low Energy Circuit Cable IMPORTANT Protect the wiring by routing it in close proximity to...

Страница 3: ...power tools on the same electrical circuit may cause oscillations on the electrical line which might cause the fixture to malfunction NOTE In order to preserve battery life the minimum working temper...

Страница 4: ...4 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not Recommended 181 240 Watts 14 AWG 12 AWG Not Recommended 241 300 Watts 12 AWG Not Recommended Not Recommended 600W Transformer 2x300 Watts 12 AWG Not Recomm...

Страница 5: ...a luz de cubierta se encienda en el modo de prueba Cubra el sensor PIR con un objeto sombreado y realice una prueba funcional preliminar Al eliminar el objeto sombreado la luz de la trayectoria se ene...

Страница 6: ...cipal de bajo voltaje No toque los contactos de metal para evitar lesiones PRECAUCI N El cable de la unidad de bajo voltaje debe ser un cable subterr neo de circuito de baja corriente tipo 12 16 AWG I...

Страница 7: ...as herramientas el ctricas en el mismo circuito el ctrico pueden causar oscilaciones en la l nea el ctrica que pueden causar un mal funcionamiento del dispositivo Limpia la l mpara con un pa o suave y...

Страница 8: ...AWG 12 AWG No Recomendado 181 240 Watts 14 AWG 12 AWG No Recomendado 241 300 Watts 12 AWG No Recomendado No Recomendado 600W transformador 2x300 Watts 12 AWG No Recomendado No Recomendado 900W transfo...

Страница 9: ...dealer or an experienced radio TV technician for help Advertencia de la FCC Advertencia los cambios o modificaciones de esta unidad que no est n expresamente aprobados por la parte responsable del cu...

Отзывы: