Receiver
Hanger bracket
Figure 9
Figure 10
6.
ON
ON
Code switch
Figure 11
Step 3.
(Fig. 11) Receiver to House Supply
Wires Electrical Connections: Connect the
black (hot) wire from the ceiling to the
black wire marked "AC in L" from the
receiver. Connect the white(neutral) wire
from the ceiling to the white wire marked
"AC in N" from the Receiver. Secure the
wire connections with the plastic wire nuts
provided.
Step 4.
(Fig. 11) If your outlet box should
have a ground wire (green or bare copper)
connect it to the fan's ground wires;
otherwise connect the hanging bracket
ground wire to the grounded metal junction
box. Secure the wire connection with a
plastic nut provided. After connecting the
wires spread them apart so that the green
and white wires are on one side of the
outlet box and black and blue wires are on
the other side. Carefully tuck the wire
connections up into the outlet box.
Note:
Fan must be installed at a maximum
distance of 20 feet from the transmitting
u n i t f o r p r o p e r s i g n a l t r a n s m i s s i o n
between the transmitting unit and the fan's
receiving unit.
CAUTION:
Do not use with wall light
dimmer switch.
SUPPLY CIRCUIT
Ground
Conductor
Outlet Box
Green
Ground
Lead
Ground to