HAMPTON BAY HI300 Скачать руководство пользователя страница 7

Hampton HI300 Wood Cast Insert

7

installation

cHiMneY  

specifications

Before installing, check and clean your chimney 

system thoroughly. If in doubt about its condi-

tion, seek professional advice. Your Hampton 

Insert is designed for installation into a masonry 

fireplace that is constructed in accordance with 

the requirements of "The Standard for Chimneys, 

Fireplaces, Vents, and Solid Fuel Burning Ap-

pliance",  N.F.P.A.  211,  the  National  Building 

Code of Canada, or the applicable local code 

requirements.  

The appliance, when installed, must be electri-

cally grounded in accordance with local codes or, 

in the absence of local codes, with the National 

Electrical Code, ANSI/NFPA 70, or the Canadian 

Electrical code, CSA C22.1.

Hampton Inserts are designed to use either a 

5.5" (140mm) or 6" (152mm) flue.

requirements for installing 

solid-fuel inserts in factory-built 

fireplaces.

1)

  The  insert  must  be  tested  and  meet  the 

requirements of UL 1482 (U.S.) and or ULC 

S628 (Canada) when tested in a masonry 

fireplace built per ULC S628.

2)

  The factory-built fireplace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry fire-

place tests are also relevant for installation 

in factory-built fireplaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 

degree  F.)  per  UL  1777  (U.S.)  or  ULC 

S635 (Canada). The liner must be securely 

attached  to  the  insert  flue  collar  and  the 

chimney top.

5)

  Means must be provided to prevent room 

air  passage  to  the  chimney  cavity  of  the 

fireplace.  This  may  be  accomplished  by 

sealing the damper area around the chimney 

liner, or sealing the fireplace front.

6)

  Alteration of the fireplace in any manner is 

not permitted with the following exceptions; 

 

a. 

  external trim pieces which do not affect 

the operation of the fireplace may be 

removed providing they can be stored 

on or within the fireplace for re-assembly 

if the insert is removed.

 

b. 

  the chimney damper may be removed 

to install the chimney liner.

Hampton Inserts are constructed with the high-

est quality materials and assembled under strict 

quality control procedures that insure years of 

trouble free and reliable performance.

It is important that you read this manual thor-

oughly  and  fully  understand  the  safe  instal-

lation  and  operating  procedures.    The  more 

you understand the way your Hampton Insert 

operates, the more enjoyment you will experi-

ence from knowing that your unit is operating 

at peak performance.

Before installinG 

Your insert

1)

  Please  read  this  entire  manual  before 

you install and use your new wood insert. 

Failure  to  follow  instructions  may  result 

in property damage, bodily injury or even 

death. Install and use only in accordance 

with manufacturer’s installation and operat-

ing instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 

a  permit  before  installing  your  insert.  Be 

aware that local codes and regulations may 

override some items in the manual.

 

WarninG:  careless installation is the 

major cause of safety hazard.  check all 

local building and safety codes before 

installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fireplace insert.

4) 

Your fireplace insert is heavy and requires 

two or more people to move it safely.  The 

insert can be badly damaged by mishan-

dling.

5)

  If  your  existing  fireplace  damper  control 

will  become  inaccessible  once  you  have 

installed your Hampton Insert, you should 

either remove or secure it in the open posi-

tion.

6)

  Inspect  your  fireplace  and  chimney  prior 

to installing your insert to determine that it 

is free from cracks, loose mortar or other 

signs of damage.  If repairs are required, 

they should be completed before installing 

your insert.  Do not remove bricks or mortar 

from your masonry fireplace.

7)

 

do not connect the insert to a chimney 

system servicing another appliance or 

an air distribution duct.

7)

  Circulating  air  chambers  (i.e.  in  a  steel 

fireplace liner or metal heat circulator) shall 

not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney flue.

9)

  Inserts that project in front of the fireplace 

must be supplied with appropriate support-

ing means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the firebox of the 

fireplace into which the insert is installed.

In order for a solid-fuel insert to be certified for use 

in factory-built fireplaces, the above information 

must be clearly stated in the installation manual 

and  appropriate  markings.  Final  approval  is 

contingent on the authority having jurisdiction.

Wood insert  

specifications

Your fireplace opening requires the
following minimum sizes:

Height

        21.5"

Width  

       25"

depth 

        17.5"

Emissions from burning  wood or gas could 

contain chemicals known to the State of Cali-

fornia to  cause cancer, birth defects or other 

reproductive harm.

"

WarninG

: This fireplace has been converted 

for use with a wood insert only and cannot be 

used  for  burning  wood  or  solid  fuels  unless 

all original parts have been replaced, and the 

fireplace re-approved by the authority having 

jurisdiction."

Содержание HI300

Страница 1: ...V4G 1H4 918 240h MODEL HI300 10 18 11 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Te...

Страница 2: ...nual please contact the HAMPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installatio...

Страница 3: ...ce 10 Standard Cast Faceplate Installation 11 Oversize Cast Faceplate Installation 14 Fan Installation 17 Power Outlet Conversion 18 Firebrick Assembly 20 Flue Baffle Secondary Air Tube Installation 2...

Страница 4: ...P MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUST IBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 0 5IN 1...

Страница 5: ...11 3 8 8 1 2 21 1 2 30 30 7 8 23 1 4 23 3 4 42 1 2 41 40 7 3 4 NOTE Before assembling your Insert use these dimensions to ensure appropriate clearances will be met refer to Masonry and Fac tory Built...

Страница 6: ...our Insert use these dimensions to ensure appro priate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section with oversize Cast faceplate 16 31 16 9 7 16 11 1 8 12 1 2...

Страница 7: ...rmance Before Installing Your Insert 1 Please read this entire manual before you install and use your new wood insert Failure to follow instructions may result in property damage bodily injury or even...

Страница 8: ...r factory built fireplace are listed below NOTE Clearances are the same with standard or oversize cast faceplate Minimum Hearth Extension for the front E and sides G are measured from the fuel door op...

Страница 9: ...remove the Door open fully and lift it up off its hinges Refer to the Door Removal section for an important note on installa tion Left Side Cast Right Side Cast Ashlip 3 Lift the unit up onto the Hear...

Страница 10: ...f a full liner as the safest installa tion and provides the most optimum performance Your retailer should be able to help you decide which system would be the best for your application 1 When installe...

Страница 11: ...vertically while each side rests on the hearth Secure using 1 bolt per bracket Side Mounting Bracket Mounting Hole Right Side Faceplate Left Side Faceplate 3 Place Mantel Top onto the top of the fireb...

Страница 12: ...adjustment bolts Cast mounting bolts for height adustment Right Side Faceplate Left Side Faceplate 7 Carefully slide the Mantel Top back into position See Step 3 to identify side casts See next page...

Страница 13: ...ECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS Stop Read Carefully Enamel Cast components are very fragile Use extreme care when handling Right Side Cast Left Side Cast 1 4 approx between both sides o...

Страница 14: ...ile each side rests on the hearth Secure using 2 bolts per bracket Side Mounting Bracket Mounting Hole Right Side Face plate Left Side Face plate 3 Place 1 1 4 x 1 Hex head bolt with 2 washers in Mant...

Страница 15: ...require 2 people it is heavy and awkward to handle Retainer Mounting Plates Gasket Location Top Faceplate Right Side Face plate Left Side Faceplate 8 Carefully slide the Mantel Top back into position...

Страница 16: ...ound in place and tighten all bolts If side cast height needs adjusting loosen 2 bolts holding cast bracket and adjust up or down Rear View of Unit RECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS SIDE...

Страница 17: ...embled carefully slide the Fan into position by centering the Fan below the Ashlip and align the Fan Support Clips with the Offset Clips under the Ashlip Note The Draft Control Rod is to fit through t...

Страница 18: ...ground wire and thermodisc assembly from the left side and relocate to the right side of the main fan housing See step 10 for Thermodisc Assembly installation Important Note Thewireharnessmaybetightbe...

Страница 19: ...sembly base See Diagram 1 11 Attach the new cover plate to the left side casting us ing 2x 6 32x3 8 Pan Head Phillips black screws Thermodisc Assembly 9 Remove the wires one at a time from the existin...

Страница 20: ...as a primary and glass wash air system the unit has a full secondary draft system that allows air to the induction ports at the top of the firebox just below the flue baffle WARNING To build a fire in...

Страница 21: ...Burn directly on the bricks 10 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 11 Do not connect your unit to any air distribu tion duct 12...

Страница 22: ...that has been dried at least one year must be used 4 A small hot fire is preferable to a large smouldering one that can deposit creosote within the system 5 Check the chimney at least twice a month d...

Страница 23: ...sretainerusingthe8screws Donot wrench down on the glass as this may cause the glass to break Handle Replacement 1 Remove handle by undoing the hex head bolt using a 7 16 socket wrench 2 Fit new door h...

Страница 24: ...t by undoing the outer 2 bolts 2 Remove the Latch from the Mounting Bracket by undoing the inner 2 bolts Latch Assembly Latch Assembly removed from unit 3 Remove necessary amount of spacers sitting on...

Страница 25: ...per Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door on a cold stove close the door Try to remove the paper by pulling The paper should not...

Страница 26: ...Gasket Part Description 8 942 661 Mantel Top 15 300 911 Fan Assembly 20 300 541 Door Assembly 21 948 175 Wooden Handle Black 948 176 Wooden Handle Dark Brown 22 300 551 Door Latch 23 940 370 P Door G...

Страница 27: ...rd Cast Faceplate Part Description 300 921 Cast Faceplate Metallic Black 300 925 Cast Faceplate Timberline Brown 300 926 Cast Faceplate Enamel Black 200 Top Faceplate 201 Left Side Faceplate 202 Right...

Страница 28: ...300 971 Oversize Cast Faceplate Metallic Black 300 975 Cast Faceplate Timberline Brown 300 Top Faceplate 301 Left Side Faceplate 302 Right Side Faceplate 303 300 060 Mounting Plate LH 300 061 Mounting...

Страница 29: ...Hampton HI300 Wood Cast Insert 29 parts list Brick Panels Part Description 180 960 Brick Set Complete...

Страница 30: ...30 Hampton HI300 Wood Cast Insert Notes...

Страница 31: ...rized dealer within three days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be...

Страница 32: ...____________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _ _____________...

Отзывы: