Hampton HI300 Wood Cast Insert

safetY label

This  is  a  copy  of  the  label  that  accompanies 

your 

Hampton insert

. We have printed a copy 

of the contents here for your review.

note: 

  Hampton  units  are  constantly  being 

improved.  Check the label on the unit and if 

there is a difference, the label on the unit is 

the correct one.

LISTE

D

F

AC

T

O

R

Y

BUIL

T

FIREPL

ACE

INSE

R

T

CER

TIFIED

FOR

USE

IN

CANADA

AN

D

U

.S.A

.

MODEL

:

HI300

TESTED

T

O

:ULC

S628-

93

/

U

L

1482

REPOR

T

NO.

219-S-03-2

DO

NOT

REMOVE

THIS

LABEL

264

COMPONENTS

REQUIRE

D

F

OR

INST

ALLA

TION:

5.5”

(140mm)

or

6”

(152MM)

ST

AINLESS

LINER

DANGER:

RISK

OF

ELECTRIC

SHOCK.

DISCONNECT

POWER

BEFORE

SER

VICING

UNIT

.

D

O

NOT

ROUTE

POWER

CORD

UNDER

OR

IN

FRONT

OF

APPLIANCE.

DO

NOT

CONNECT

THIS

UNIT

T

O

A

CHIMNEY

FLUE

SER

VICING

ANOTHER

APPLIANCE.

DO

NOT

REMOVE

BRICKS

OR

MOR

TA

R

IN

MASONR

Y

F

IREPLACE.

FO

R

U

SE

WITH

SOLID

WOOD

FUEL

ON

L

Y

.

D

O

N

O

T

USE

GRA

TE

OR

ELEV

A

T

E

FIRE.

BUILD

WOOD

FIRE

DI

RECT

L

Y

ON

HEAR

TH.

OPERA

TE

WITH

FEED

DOOR

CLOSED

,

O

PEN

T

O

FEED

FI

RE

ON

L

Y

.

R

EPLACE

GLASS

ONL

Y

WITH

CERAMI

C

G

LASS

(5MM)

.

INSPECT

AN

D

C

LEAN

CHIMNE

Y

F

R

E

Q

U

E

N

T

L

Y

.

UNDER

CER

TAIN

CONDITIONS

OF

US

E

C

REOSOT

E

B

UILDUP

MA

Y

OCCUR

RAPIDL

Y

.

DO

NOT

OVERFIRE

,

IF

INSER

T

G

LOWS

YO

U

A

RE

OVER-FIRING.

MINIMUM

CLEARANCES

T

O

COMBUST

IBLE

MA

TERIA

LS

(MEASURE

D

F

ROM

INSE

R

T

BODY

)

INST

ALL

ONL

Y

O

N

A

N

ON-COMBUSTIBLE

HEAR

TH

RAISED

(F)

0.5IN

/

13M

M

ABOVE

AN

ADJACENT

COMBUSTIBLE

FLOOR.

COMBUSTIBLE

FLOOR

MUS

T

BE

PROTECTED

BY

NON-COMBUSTIBLE

MA

TERIA

L

E

XTENDING

(E

)

1

8

IN

/

457M

M

T

O

FRONT

AN

D

(G)

8

IN

/

205M

M

T

O

SIDES

FROM

FUEL

DOOR.

0.5”

FLOOR

PROTECTIO

N

N

EEDS

T

O

BE

WIT

H

K

=

0.84.

918-241b

MANUF

ACTURED

BY

:

FPI

FIREPLACE

PRODUCTS

INTERNA

TIONAL

L

TD.

6988

VENTURE

ST

.

DEL

T

A

,

B

C

V4G

1H4

HOT

WHILE

IN

OPERA

TION

DO

NOT

T

OUCH.

KEEP

CHILDREN,

CLOTHING

AND

FURNITURE

A

W

A

Y

.

CONT

ACT

MA

Y

CAUSE

SKIN

BURNS

.

READ

ABOVE

INSTRUCTIONS.

CAUTION

ADJACEN

T

S

IDEW

ALL

A)

1

1

in

/

280m

m

MANTL

E

B

)

20in

/

510m

m

T

O

P

F

AC

IN

G

C

12in

/

355

mm

SIDE

F

A

CIN

G

D)

8in

/

185m

m

INS

T

A

LL

AN

D

USE

ONL

Y

IN

ACCORDANCE

WITH

TH

E

M

ANUF

ACTURER'

S

INST

ALLA

TIO

N

A

ND

OPERA

TIN

G

INSTRUCTIONS

.

INST

AL

L

A

N

D

USE

ONL

Y

IN

MASONR

Y

FIREPLAC

E

O

R

F

ACT

OR

Y

B

UI

L

T

FIREPL

ACE.

CONT

ACT

LOCA

L

B

UILDIN

G

O

R

FIR

E

O

FFICIALS

ABOUT

RESTRICTIONS

AN

D

INST

ALLA

TIO

N

INSPECTIO

N

IN

Y

OUR

AREA

.

UNITED

ST

A

T

E

S

ENVIRONMENT

AL

PR

OTECTION

AGENCY

CER

TIFIED

T

O

COMPL

Y

W

ITH

JUL

Y

1

990,

P

A

R

TICULA

TE

EMISSION

ST

ANDARD

S.

JAN

FEB

MAR

APR

MA

Y

JU

N

JUL

AU

G

SEPT

OCT

NOV

DE

C

201

1

2012

2013

(Duplicate

Serial

#)

MADE

IN

CAN

ADA

264

DA

TE

OF

MANUF

ACTUR

E

safetY laBel for Hi300

Содержание HI300

Страница 1: ...V4G 1H4 918 240h MODEL HI300 10 18 11 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Te...

Страница 2: ...nual please contact the HAMPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installatio...

Страница 3: ...ce 10 Standard Cast Faceplate Installation 11 Oversize Cast Faceplate Installation 14 Fan Installation 17 Power Outlet Conversion 18 Firebrick Assembly 20 Flue Baffle Secondary Air Tube Installation 2...

Страница 4: ...P MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUST IBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 0 5IN 1...

Страница 5: ...11 3 8 8 1 2 21 1 2 30 30 7 8 23 1 4 23 3 4 42 1 2 41 40 7 3 4 NOTE Before assembling your Insert use these dimensions to ensure appropriate clearances will be met refer to Masonry and Fac tory Built...

Страница 6: ...our Insert use these dimensions to ensure appro priate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section with oversize Cast faceplate 16 31 16 9 7 16 11 1 8 12 1 2...

Страница 7: ...rmance Before Installing Your Insert 1 Please read this entire manual before you install and use your new wood insert Failure to follow instructions may result in property damage bodily injury or even...

Страница 8: ...r factory built fireplace are listed below NOTE Clearances are the same with standard or oversize cast faceplate Minimum Hearth Extension for the front E and sides G are measured from the fuel door op...

Страница 9: ...remove the Door open fully and lift it up off its hinges Refer to the Door Removal section for an important note on installa tion Left Side Cast Right Side Cast Ashlip 3 Lift the unit up onto the Hear...

Страница 10: ...f a full liner as the safest installa tion and provides the most optimum performance Your retailer should be able to help you decide which system would be the best for your application 1 When installe...

Страница 11: ...vertically while each side rests on the hearth Secure using 1 bolt per bracket Side Mounting Bracket Mounting Hole Right Side Faceplate Left Side Faceplate 3 Place Mantel Top onto the top of the fireb...

Страница 12: ...adjustment bolts Cast mounting bolts for height adustment Right Side Faceplate Left Side Faceplate 7 Carefully slide the Mantel Top back into position See Step 3 to identify side casts See next page...

Страница 13: ...ECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS Stop Read Carefully Enamel Cast components are very fragile Use extreme care when handling Right Side Cast Left Side Cast 1 4 approx between both sides o...

Страница 14: ...ile each side rests on the hearth Secure using 2 bolts per bracket Side Mounting Bracket Mounting Hole Right Side Face plate Left Side Face plate 3 Place 1 1 4 x 1 Hex head bolt with 2 washers in Mant...

Страница 15: ...require 2 people it is heavy and awkward to handle Retainer Mounting Plates Gasket Location Top Faceplate Right Side Face plate Left Side Faceplate 8 Carefully slide the Mantel Top back into position...

Страница 16: ...ound in place and tighten all bolts If side cast height needs adjusting loosen 2 bolts holding cast bracket and adjust up or down Rear View of Unit RECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS SIDE...

Страница 17: ...embled carefully slide the Fan into position by centering the Fan below the Ashlip and align the Fan Support Clips with the Offset Clips under the Ashlip Note The Draft Control Rod is to fit through t...

Страница 18: ...ground wire and thermodisc assembly from the left side and relocate to the right side of the main fan housing See step 10 for Thermodisc Assembly installation Important Note Thewireharnessmaybetightbe...

Страница 19: ...sembly base See Diagram 1 11 Attach the new cover plate to the left side casting us ing 2x 6 32x3 8 Pan Head Phillips black screws Thermodisc Assembly 9 Remove the wires one at a time from the existin...

Страница 20: ...as a primary and glass wash air system the unit has a full secondary draft system that allows air to the induction ports at the top of the firebox just below the flue baffle WARNING To build a fire in...

Страница 21: ...Burn directly on the bricks 10 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 11 Do not connect your unit to any air distribu tion duct 12...

Страница 22: ...that has been dried at least one year must be used 4 A small hot fire is preferable to a large smouldering one that can deposit creosote within the system 5 Check the chimney at least twice a month d...

Страница 23: ...sretainerusingthe8screws Donot wrench down on the glass as this may cause the glass to break Handle Replacement 1 Remove handle by undoing the hex head bolt using a 7 16 socket wrench 2 Fit new door h...

Страница 24: ...t by undoing the outer 2 bolts 2 Remove the Latch from the Mounting Bracket by undoing the inner 2 bolts Latch Assembly Latch Assembly removed from unit 3 Remove necessary amount of spacers sitting on...

Страница 25: ...per Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door on a cold stove close the door Try to remove the paper by pulling The paper should not...

Страница 26: ...Gasket Part Description 8 942 661 Mantel Top 15 300 911 Fan Assembly 20 300 541 Door Assembly 21 948 175 Wooden Handle Black 948 176 Wooden Handle Dark Brown 22 300 551 Door Latch 23 940 370 P Door G...

Страница 27: ...rd Cast Faceplate Part Description 300 921 Cast Faceplate Metallic Black 300 925 Cast Faceplate Timberline Brown 300 926 Cast Faceplate Enamel Black 200 Top Faceplate 201 Left Side Faceplate 202 Right...

Страница 28: ...300 971 Oversize Cast Faceplate Metallic Black 300 975 Cast Faceplate Timberline Brown 300 Top Faceplate 301 Left Side Faceplate 302 Right Side Faceplate 303 300 060 Mounting Plate LH 300 061 Mounting...

Страница 29: ...Hampton HI300 Wood Cast Insert 29 parts list Brick Panels Part Description 180 960 Brick Set Complete...

Страница 30: ...30 Hampton HI300 Wood Cast Insert Notes...

Страница 31: ...rized dealer within three days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be...

Страница 32: ...____________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _ _____________...

Отзывы: