HAMPTON BAY H200 Скачать руководство пользователя страница 4

4

Hampton H200 Cast Freestanding Woodstove

SAFETY LABEL

This is a copy of the label that accompanies 
each Hampton H200 Freestanding Woodstove. 
We have printed a copy of the contents here 
for your review.

NOTE:

 Hampton units are constantly being 

improved. Check the label on the unit and if 
there is a difference, the label on the unit is the 
correct one.

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

290

CERTIFIED TO COMPLY WITH JULY 1990

PARTICULATE EMISSION STANDARDS.

UNITED STATES  ENVIRONMENTAL 

PROTECTION  AGENCY

MADE IN CANADA

 JAN 

  FEB 

 MAR 

 APR 

 MA

Y

 

 JUN 

 JUL

 

 AUG  

 SEPT 

 OCT 

 NOV 

 DEC

CAUTION

DA

TE OF MANUF

ACTURE

918-428a  

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 
SUITABLE FOR MOBILE HOME INSTALLATION 

MODEL:  HAMPTON  CAST FREESTANDING WOOD STOVE -  H200

TESTED TO: UL-1482 / ULC-S627-00   

REPORT NO: 219-S-09-2

MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL 

A  431  mm / 17 in 

D  737 mm / 29 in

BACKWALL  B  381  mm / 15 in 

E  435 mm / 17-1/8 in

CORNER 

C  330  mm / 13 in 

F  505 mm / 19-7/8 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A  381  mm / 15 in 

D 686 mm / 27 in

BACKWALL  B  254  mm / 10 in 

E 308 mm / 12-1/8 in

CORNER 

C  228  mm / 9 in 

F 403 mm / 15-7/8 in 

SIDEWALL 

A  381 mm / 15  in 

D 686 mm / 27 in

BACKWALL  B  254  mm / 10 in 

E 308 mm / 12-1/8 in

CORNER 

C  228  mm / 9 in 

F 403 mm / 15-7/8 in 

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

MINIMUM ALCOVE CEILING HEIGHT: 1.5 M / 5 FT         MAXIMUM ALCOVE DEPTH 1220 MM / 48 IN.    
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 457 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

FLOOR 

PROTECTION*

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR 
AREA.  USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED 
UL103 HT FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING 
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY CONNECTOR THROUGH 
COMBUSTIBLE WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER 
APPLIANCE.

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT 
COMBUSTION AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE 
ONLY.  DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR 
GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE CREOSOTE 
BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH 
NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE 
FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF 
APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:  LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: 
SECURITY MODEL S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.
IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL 
DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL 
S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, 
AMERI-TECHS,  ICC EXCEL 2100, SIMPSON DURA PLUS HTC .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

MEASURE 

   

 

 

         FLUE

FROM  

        HEATER   

        CENTER-LINE

MANUFACTURED BY:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC  V4G 1H4

SIDEWALL 

G 381 mm / 15 in 

I  686 mm / 27 in

BACKWALL  H  330 mm / 13 in 

J  384 mm / 15-1/8 in

2010

2012

201

1

290

 

 

* In Canada, fl oor protection must extend 18" 
(457mm) to the front and 8" (200mm) to each 
side and back of the stove.

K  457 mm  /  18 in
L  150 mm  /  6 in
M  150 mm  /  6 in

Содержание H200

Страница 1: ...G 1H4 918 427a MODEL H200 Freestanding Woodstove 10 25 11 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for...

Страница 2: ...manual please contact the HAMPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this woodstove is not properly installed a house fire may result For your safety follow the insta...

Страница 3: ...Mobile Home Installation 16 Listed Components For Mobile Home Installation 17 Brick Installation 18 Door Removal 18 Optional Short Leg Installation 18 Optional Blower Fan Installation 19 Optional Sid...

Страница 4: ...ND MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING DO NOT CONNECT THI...

Страница 5: ...Hampton H200 Cast Freestanding Woodstove 5 DIMENSIONS UNIT DIMENSIONS WITH STANDARD LEGS...

Страница 6: ...6 Hampton H200 Cast Freestanding Woodstove DIMENSIONS UNIT DIMENSIONS WITH OPTIONAL SHORT LEGS...

Страница 7: ...sed only on Vertical Installations 1 Loosen the bolts that secure the elbow to the unit Ensure elbow does not fall off 2 Bendthetabsontherearheatshieldinwards 90 degrees Rear Heat Shield Slide tabs in...

Страница 8: ...Some areas may require a larger size floor protector However when installing the unit with the short leg option there is a requirement of 0 84k of floor protector beneath the non combustible finished...

Страница 9: ...m 27 686 mm 12 1 8 308 mm 15 7 8 403mm Mobile Home Close Clearance To be installed with required pipe components C Vent single wall pipe is not approved for Mobile Home installations refer to Mobile H...

Страница 10: ...m Flue Min Min Hearth Unit with Heat Shield Unit Center line Width to Rear Wall G H I J K L H200 15 381 mm 13 330 mm 27 686 mm 15 1 8 384 mm 54 1372 mm 50 1270 mm ADDITIONAL CLEARANCES FOR BACKWALL EX...

Страница 11: ...te R of proposed system 4 brick of C 1 25 therefore Rbrick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compa...

Страница 12: ...optimum efficiency when installing into a masonry chimney size accordingly i e the 6 152mm flue dia is 28 28 sq in 8 Tocompleteyourchimneyinstallation install the double wall connector pipe from the s...

Страница 13: ...stallation MASONRY CHIMNEY Ensurethatamasonrychimneymeetstheminimum standardsoftheNationalFireProtectionAssociation NFPA by having it inspected by a professional Make sure there are no cracks loose mo...

Страница 14: ...mney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a...

Страница 15: ...ample b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA...

Страница 16: ...yshouldprojectatleast2ft 610mm above the highest elevation of any part of the Mobile Home within 10 ft 3048mm of the chimney 7 ThechimneysystemshallcomplywithLocal Requirements 8 Any openings in a chi...

Страница 17: ...3 Chimney Length 1 SL1 Chimney Length 1 RCSA Rain Cap SECURITY ASHT Qty Part Description 1 DL42A 6 Connector Kit 1 6SS Shield Support 1 6FAMH Flashing 1 6L3 Chimney Length 1 6L1 Chimney Length 1 CPE R...

Страница 18: ...oor lifts right out Bottom part of door fits into slot Optional Ash Plug shown OPTIONAL SHORT LEG INSTALLATION 1 Remove the cast lid from the top of the stove 2 Remove fan if installed 3 Carefully lay...

Страница 19: ...nding prong from the power cord Do not use an adaptor plug CAUTION Movingpartsmaycauseinjury Do not operate unit with blower housing removed DANGER Risk of electric shock Discon nect power before serv...

Страница 20: ...of Right Hand Side Shelf Shown Gusset Side Casting Left side of stove shown Front Casting Bracket Cut Out Bracket Cut Out NOTE Ensure that the Bracket cut out is towards the back of the stove NOTE Whe...

Страница 21: ...2 nuts and bolts holding the 2 plates together from underneath the stove 4 Re install bottom tray and then install the 2 ash drawer rails to the bottom tray using 4 bolts 5 Slide the ash drawer on top...

Страница 22: ...mporary condition exists Burning the stove at a very high temperaturethefirstfewtimesmaydamage the paint Burn fires at a moderate level the first few days 8 Do not place anything on the stove top duri...

Страница 23: ...he stove is in use 9 Do not connect this unit to a chimney flue serving another appliance 10 Do not use grates or andirons or other methods for supporting fuel Burn directly on the bricks 11 Open the...

Страница 24: ...ing lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by buria...

Страница 25: ...ill produce In the event that you break your glass by impact purchase your replacement from an authorized Hampton dealer only and follow our step by step Glass Installation Replacement instructions re...

Страница 26: ...behind screws Allen Key Hex Head Bolt Lock Washer Handle Spacer Front Door Handle Shown LATCH ADJUSTMENT METHOD The door bracketry may require adjustment as thedoorgasketmaterialcompressesafterafew f...

Страница 27: ...rom the Firebox Top Assembly and lift off Top Hob 3 Remove the left and right baffle caps by removing the 2 bolts 7 16 socket 1 4 20 x 1 2 hex head on each side and lift out 4 Remove the three 7 16 so...

Страница 28: ...ed Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door on a cold stove close the door Try to remove the paper by pulling The paper should...

Страница 29: ...IMBERLINE BROWN 18 200 960 BRICK SET 19 200 110 FIREBOX FRONT 20 200 160 ANDIRON X2 21 200 120 FIREBOX INNER 22 200 217 BRACKET HINGE 23 200 361 FRONT VENTS CHARCOAL GREY 200 365 FRONT VENTS TIMBERLIN...

Страница 30: ...30 Hampton H200 Cast Freestanding Woodstove PARTS LIST 2 2 2 22 2 2 2 2 2 2 2 0 2 0 20...

Страница 31: ...Cast Freestanding Woodstove 31 H200 DOOR ASSEMBLY PARTS LIST PART DESCRIPTION 2 0 2 200 2 F 2 200 2 F 2 200 220F 2 0 mm C 2 2 2 H 200 CH C 200 W 220 H 220 0 CH 0 220 0 C H 2 0 0 F W H 0 2 C W H 0 202...

Страница 32: ...32 Hampton H200 Cast Freestanding Woodstove PARTS LIST H200 ASH DRAWER ASSEMBLY PART DESCRIPTION 200 H W C 2 0 H 2 2 2 200 2 2 H W H 200 2 H W F 20 2 H H 2...

Страница 33: ...LIST RED LOW WHITE COMMON CONNECTION DIAGRAM BLACK HIGH 115V 60HZ 1 1A J250 150 O44003 T P 3000 RPM JAKEL INC DATE T P L B 200 F C 220 02 F H F 2 220 022 F H 220 0 200 22 F C H H 200 22 F C F H 200 22...

Страница 34: ...34 Hampton H200 Cast Freestanding Woodstove NOTES...

Страница 35: ...hree days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced...

Страница 36: ...__________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today...

Отзывы: