 H15-1 Direct Vent Freestanding Gas Stove

5

REQUIREMENTS 

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 
be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 
monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 
sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 
5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 
the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 
structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 
instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 
"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 
detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 
the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Содержание H15-LP1

Страница 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Страница 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H15 1 has been approved by Warnock Hersey for both safety...

Страница 3: ...ale 6 Before You Start 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove 8 Manufactured Mobile Home Additional Requirements 8 Combustion and...

Страница 4: ...he correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exible connecto...

Страница 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 6: ...hetypeofgasindicatedontherating plate This appliance is not convert ible for use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI FIEDSERVICEPERSON THI...

Страница 7: ...equire ments See Venting Introduction to Dura Vent Vertical Termination sections 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Pilot Adjustmen...

Страница 8: ...ATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 Fan Speed Control 1 Grommet 1 Remove the rear access panel on the back of the sto...

Страница 9: ...ged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 12 Sl...

Страница 10: ...fcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the ch...

Страница 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Страница 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Страница 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 14: ...t Temp Ameri Vent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNI...

Страница 15: ...8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertic...

Страница 16: ...etween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 fee...

Страница 17: ...talled in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with hori zont...

Страница 18: ...lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the exible liner will accommodate However keep the...

Страница 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Страница 20: ...ering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex liner to the desi...

Страница 21: ...Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 380 946 Horizontal Termination Kit which includes 1 6...

Страница 22: ...ter wall of the vent pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements fromdecks windows sof ts gasregulators air supply inlets and publi...

Страница 23: ...of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards the termination...

Страница 24: ...e For best results and optimum per formancewitheachapprovedventing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in draf...

Страница 25: ...rformance issues notcoveredunderwarranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportB...

Страница 26: ...ecured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure...

Страница 27: ...Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the support in the opening Lower it to the correct height as determined by the tab...

Страница 28: ...ter turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do not over tighten Valve Description 1 Gas on off knob 2 Manual...

Страница 29: ...elcro Hook Black 904 782 Velcro Hook Black 1 Shut off the gas supply 2 Lift off Cast Top remove Cast Front and Glass Door refer to the glass replace ment section in the manual and carefully remove log...

Страница 30: ...nel Before After 12 Pull off the pilot cap to expose the pilot ori ce 13 Unscrew the pilot ori ce with the allen key and replace with the LP pilot ori ce in the kit 14 Remove burner ori ce with a 1 2...

Страница 31: ...wire to the DC Sparker Piezo Ignitor 31 Attach the heat shield to the DC sparker then mount onto the stove using the velcro already attached to the DC Sparker mounting bracket Note We recommend attac...

Страница 32: ...r Front Log e Embers 902 156 f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log A B 4 Remove Glass Door 5 Carefully remove the logs from the unit and unwrap them Th...

Страница 33: ...any ame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top D A A B C D 8 Take the embers and place on the burner in the space between the...

Страница 34: ...ed non anticipator type thermostat that is CSA ULC or UL approved may be used 14 GA 16 GA 18 GA 20 GA 22 GA 50 Ft 32 Ft 20 Ft 12 Ft 9 Ft Recommended Maximum Lead Length Two Wire When Using Wall Thermo...

Страница 35: ...failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do no...

Страница 36: ...ton H15 1 Direct Vent Freestanding Gas Stove INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this...

Страница 37: ...ew res a white lm may develop on the glass front as part of the curing process The glass should be cleaned or the lm will bake on and become very dif cult to remove Use a non abrasive cleaner and NEVE...

Страница 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Страница 39: ...Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process SHOULD BE ALERTE...

Страница 40: ...rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully rem...

Страница 41: ...the burner tray assembly simply reverse these instructions To remove valve from valve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pil...

Страница 42: ...023 Fan De ector Left 17 910 142 Thermodisc Switch 20 380 012 Rear Panel 25 910 330 Fan Speed Control 120V 26 904 569 Knob Fan Speed Control 28 910 241 Burner ON OFF Switch 29 260 037 Rear Control Pan...

Страница 43: ...Nut 64 908 672 Control Panel Decal 65 490 061 Switch Plate 936 170 Ori ce Gasket 66 910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 380 013 Pilot Holder 68 W840470 Pilot Assembl...

Страница 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Страница 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Отзывы: