HAMPTON BAY H15-LP1 Скачать руководство пользователя страница 42

42

Hampton

®

 H15-1 Direct Vent Freestanding Gas Stove

PARTS LIST

MAIN ASSEMBLY

         Part #      Description 

 

            Part #      Description 

 

 

      Part #      Description

1) 942-601** 

Casting 

Top

2) 

942-621**  Casting - Side & Leg

3) 942-611** 

Casting 

Front

6) 

770-066F 

Top Relief Plate

7) 

W260280 

Top Relief Plate Gasket

8) 770-067F 

Plate 

Insulation 

Holder

9) 

942-117 

Top Relief Frame

10) 

W260260 

Top Relief Frame Gasket

11) 945F 

Dura-Vent 

Collar

12) W842051 Gasket 

for 

Flue 

Adaptor

13) 

W260108 

Gasket for Inner Flue

14) * 

Rear 

Bracket

15) 

380-024 

Fan Defl ector - Right

16) 

380-023 

Fan Defl ector - Left

17) 910-142  Thermodisc 

Switch

20) 380-012  Rear 

Panel

25) 

910-330 

Fan Speed Control (120V)

26) 

904-569 

Knob - Fan Speed Control

28) 910-241  Burner 

ON/OFF 

Switch

29) 

260-037 

Rear Control Panel

35) 380-002  Firebox 

Bracket 

Left

36) 380-003  Firebox 

Bracket 

Right

38) 380-034  Casting 

Mount 

Bracket

45) 380-001  Door 

Support

46) 380-010  Baffl e Plate of Firebox

47) 380-011  Restrictor
50) 

948-255 

Latch Ojop W/J-Hook

51) 940-338/P Replacement 

Glass

52) 41225 

Gasket 

Tadpole

53) 380-008  Glass 

Bracket

54) 380-007  Door 

Frame

56) 

910-157/P  Fan Motor (120 V)

57) 910-794  Power 

Cord 

(120 

V)

 918-516 

Manual

* Not available as a replacement part.

** Last digit of part number represents colour:
3=Slate Blue, 4=Ivory, 5=Timberline Brown.

Содержание H15-LP1

Страница 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Страница 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H15 1 has been approved by Warnock Hersey for both safety...

Страница 3: ...ale 6 Before You Start 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove 8 Manufactured Mobile Home Additional Requirements 8 Combustion and...

Страница 4: ...he correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exible connecto...

Страница 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 6: ...hetypeofgasindicatedontherating plate This appliance is not convert ible for use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI FIEDSERVICEPERSON THI...

Страница 7: ...equire ments See Venting Introduction to Dura Vent Vertical Termination sections 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Pilot Adjustmen...

Страница 8: ...ATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 Fan Speed Control 1 Grommet 1 Remove the rear access panel on the back of the sto...

Страница 9: ...ged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 12 Sl...

Страница 10: ...fcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the ch...

Страница 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Страница 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Страница 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 14: ...t Temp Ameri Vent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNI...

Страница 15: ...8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertic...

Страница 16: ...etween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 fee...

Страница 17: ...talled in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with hori zont...

Страница 18: ...lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the exible liner will accommodate However keep the...

Страница 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Страница 20: ...ering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex liner to the desi...

Страница 21: ...Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 380 946 Horizontal Termination Kit which includes 1 6...

Страница 22: ...ter wall of the vent pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements fromdecks windows sof ts gasregulators air supply inlets and publi...

Страница 23: ...of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards the termination...

Страница 24: ...e For best results and optimum per formancewitheachapprovedventing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in draf...

Страница 25: ...rformance issues notcoveredunderwarranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportB...

Страница 26: ...ecured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure...

Страница 27: ...Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the support in the opening Lower it to the correct height as determined by the tab...

Страница 28: ...ter turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do not over tighten Valve Description 1 Gas on off knob 2 Manual...

Страница 29: ...elcro Hook Black 904 782 Velcro Hook Black 1 Shut off the gas supply 2 Lift off Cast Top remove Cast Front and Glass Door refer to the glass replace ment section in the manual and carefully remove log...

Страница 30: ...nel Before After 12 Pull off the pilot cap to expose the pilot ori ce 13 Unscrew the pilot ori ce with the allen key and replace with the LP pilot ori ce in the kit 14 Remove burner ori ce with a 1 2...

Страница 31: ...wire to the DC Sparker Piezo Ignitor 31 Attach the heat shield to the DC sparker then mount onto the stove using the velcro already attached to the DC Sparker mounting bracket Note We recommend attac...

Страница 32: ...r Front Log e Embers 902 156 f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log A B 4 Remove Glass Door 5 Carefully remove the logs from the unit and unwrap them Th...

Страница 33: ...any ame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top D A A B C D 8 Take the embers and place on the burner in the space between the...

Страница 34: ...ed non anticipator type thermostat that is CSA ULC or UL approved may be used 14 GA 16 GA 18 GA 20 GA 22 GA 50 Ft 32 Ft 20 Ft 12 Ft 9 Ft Recommended Maximum Lead Length Two Wire When Using Wall Thermo...

Страница 35: ...failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do no...

Страница 36: ...ton H15 1 Direct Vent Freestanding Gas Stove INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this...

Страница 37: ...ew res a white lm may develop on the glass front as part of the curing process The glass should be cleaned or the lm will bake on and become very dif cult to remove Use a non abrasive cleaner and NEVE...

Страница 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Страница 39: ...Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process SHOULD BE ALERTE...

Страница 40: ...rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully rem...

Страница 41: ...the burner tray assembly simply reverse these instructions To remove valve from valve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pil...

Страница 42: ...023 Fan De ector Left 17 910 142 Thermodisc Switch 20 380 012 Rear Panel 25 910 330 Fan Speed Control 120V 26 904 569 Knob Fan Speed Control 28 910 241 Burner ON OFF Switch 29 260 037 Rear Control Pan...

Страница 43: ...Nut 64 908 672 Control Panel Decal 65 490 061 Switch Plate 936 170 Ori ce Gasket 66 910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 380 013 Pilot Holder 68 W840470 Pilot Assembl...

Страница 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Страница 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Отзывы: