MAX
4'
Wall Thimble
Horizontal frame
for thimble
Clean out Tee
Wall framing
Vertical
section of
4" vent
pipe
Wall Strap
4" 90
Elbow with
Screen or
Termination Cap
Wall Strap
Installation
recommended
- t
hrough
W
all
W
ith
v
ertical
r
iSe
and
h
orizontal
t
ermination
i
nStallation
:
Figure 13: Venting horizontally with rise.
t
hrough
c
oncrete
W
all
W
ith
v
ertical
r
iSe
i
nStallationS
:
Concrete Wall
Clean Out Tee
Wall Framing
Horizontal frame
for thimble
4" 90 Elbow
Vertical section
of 4" pipe
Wall Thimble
4" 45 Elbow
with screen or
Termination
Cap
Installation to use if there is a concrete or
retaining wall in line with exhaust vent on
pellet stove.
A 45° down elbow with a screen may be used
in place of the termination cap (or stainless
steel termination hood).
The termination must be 12 inches (30 cm)
from the outside wall and 12 inches (30 cm)
above the ground.
Figure 14: Venting with concrete wall behind unit .
A 45° down elbow with a screen may be used in
place of the termination cap (or stainless steel
termination hood).
Hampton GC60-2 Cast Pellet Stove Technical Manual
16