HAMPTON BAY GCI60 Скачать руководство пользователя страница 6

Specifications

R

ATING

 L

ABEL

 & L

OCATION

:

The rating label is located on the top of the hopper.

Figure 1: GCI60 Rating Label. 

Certified for use in Canada & USA

Certifié pour installation au 

Canada et aux Etats-Unis.

Model / Modèle: GCI60

Listed Room Heater

, Pelletized Fuel 

T

ype (Appareil de chauf

fage à granules  certifié)

Input rating when using: Wood Pellets/Corn - 55,000BTU (16.1KW*hr)  Wheat/Barley - 53,000BTU (15.5KW*hr)

(Le chauffage d'énergie avec: Boulettes de bois/lMaïs - 55,000BTU (16.1KW*hr) Blé/l'Orge - 53,000BTU (15.5KW*hr)) 

Tested to (Testée selon): ASTM 1509-04.  US Environmental Protection Agency, certified to comply July 1, 1990, particulate 

emission standards. (États-Unis Environnemental Protection Agence, a certifié pour conformer au Juillet 1, 1990, les normes de 

particules d'émission.) 

Standard for Fireplace Inserts / Norme pour des Insertions de Cheminée: ULC S628

Install and use only in accordance with the manufacturer's installation and operating instructions. Contact local building 

or fire of

ficials about restrictions and installation inspection in your area.  Do not connect this unit to a chimney flue 

serving

 another

 appliance.

 Inspect

 and

 clean

 exhaust

 venting

 system

 frequently

. See

 local

 building

 code

 and

 

manufacturer's instructions for precautions required for passing a chimney through a combustible wall or ceiling. 

 

ELECTRICAL

 RA

TING: 120 V

olts, 60Hz, 4.2 

Amps.  Route Cord 

A

way From Heater

.

For use with pelletized solid fuels - wood, corn, wheat, & barley only

. Operate only with viewing door and ash removal 

door closed. Only replace glass with ceramic glass. 

Components required for installation:  listed 4inch (100 mm) 

stainless steel chimney liner. 

 

Installez et utilisez cet appareil seulement selon les instructions d'installation et d'opération du fabricant. Contactez les 

autorités locales de votre quartier concernant les restrictions et les inspections d'installation. Inspectez et nettoyez le 

système d'échappement fréquemment. Consultez les codes de bâtiment locaux et les instructions du fabricant pour les 

précautions à prendre lorsque une cheminée doit être installée au travers un mur ou un plafond combustible. 

CLASSEMENT

 ÉLECTRIQUE : 120 V

olts, 60 Hz, 4.2 

Amps. Placez le câble électrique loin de la chaleur

Manufactured in Canada for /

Fabriqué dans le Canada pour:

FPI Fireplace Products International Ltd.

Delta, BC, Canada

DATE OF MANUFACTURE / 

DATE DE FABRICATION:

J     F      M     A    M    J     J     A     S     O     N     D          2011     2012     2013

CAUTION:

HOT

 WHILE IN OPERA

TION. DO 

NOT

 T

O

UCH. KEEP

 CHILDREN, 

CLOTHING AND 

FURNITURE 

A

W

A

Y

.  CONT

ACT

 MA

Y

 CAUSE 

BURNS. SEE NAMEPLA

TE 

AND 

INSTRUCTIONS.

 

ATTENTION:

L'APP

AREIL

 EST

 CHAUD LORSQU'IL

                                                             

FONCTIONNE. NE P

AS 

T

O

UCHER. GARDER LES ENF

A

NTS, 

LES VÊTEMENTS ET

 LES MEUBLES ÉLOIGNÉS DE 

L'APP

AREIL

 EN MARCHE. UN CONT

ACT

 A

VEC CELUI-CI 

POURRAIT

 RÉSUL

TER EN DES BRÛLURES. VEUILLEZ 

VOIR LA

 PLAQUE DU F

ABRICANT

 ET

 LES INSTRUCTIONS.

DO NOT REMOVE THIS LABEL / 

NE RETIREZ P

AS CETTE ÉTIQUETTE

GCI60-006

384

Serial No. / No. De Serié:

To

 Start Stove: Select fuel type mode; PREMIUM PELLETS for superior quality pellet fuel, REGULAR PELLETS for all 

grades of wood pellets & MUL

TIFUEL

 for all other fuels. Press the ON / OFF button. For first time use, a small handful 

of pellets in the burn pot liner will speed up ignition.

To

 Operate Stove: MANUAL

 MODE: When a fire has been established the stove settings are adjustable. / HIGH/LOW 

MODE: (Requires a thermostat) When the thermostat calls for heat the stove settings are adjustable.  When the 

thermostat contacts open, the HEA

T

 LEVEL

 and Fans will drop down to the LOW setting until the thermostat contacts 

close again. / 

AUT

O/OFF MODE: (Requires a thermostat) When the thermostat contacts close, the unit will light 

automatically

. Once up to temperature the stove settings are adjustable. When the thermostat contacts open, the stove 

will drop down to the LOW settings for 30 minutes. If within the 30 min the thermostat contacts close, the HEA

T

 LEVEL

 

will return to previous MANUAL

 setting or if the thermostat contacts remain open the stove begin its shutdown routine 

and it will restart when the thermostat closes.

To

 T

u

rn Of

f Stove: MANUAL

 and HI / LOW mode: Press the ON / OFF button

AUT

O / OFF mode: 

T

u

rn the thermostat down or of

f.

Pour démarrer le poêle: Choisir le mode pour le carburant ; PREMIUM PELLETS pour le carburant de boulette de 

qualité de superior

, REGULAR PELLET

 pour tous degrés de boulettes de bois & MUL

T

IFUEL

 pour tous autres 

carburants. 

Appuyer sur le bouton "ON/OFF". Pour l’usage de première fois, une petite poignée de boulettes dans le 

pot de brûlure hâtera l'allumage. 

Pour faire fonctionner le poêle :  MODE MANUEL

 : Lorsque le feu est bien établi, les réglages peuvent être ajustés. / 

MODE "HIGH/LOW" : (Nécessite un thermostat) Lorsque le  thermostat requière de la chaleur

, les réglages peuvent 

être

 ajustés.

 Lorsque

 les

 contacts

 du

 thermostat

 ouvrent,

 le

 réglage

 du

 niveau

 de

 chaleur

 et

 les

 ventilateurs

 

s'ajusteront au réglage " bas " jusqu'à ce que les contacts du thermostat se referment. / MODE "AUT

O/OFF" : 

(Nécessite un thermostat) Lorsque les contacts du thermostat ferment, le poêle s'allumera automatiquement. Lorsque 

la température adéquate est atteinte, les réglages peuvent être ajustés. Lorsque les contacts du thermostat ouvrent, le 

poêle s'ajustera aux réglages "LOW" pendant 30 minutes. Si les contacts du thermostat sont fermés pendant ces 30 

minutes, le réglage de niveau de chaleur retournera en réglages "MANUEL" ou si les contacts du thermostat restent 

ouverts, le poêle entamera le processus d'arrêt et il vouloir redémarrer lorsque les contacts du thermostat refermer

Pour éteindre le poêle : MODE MANUEL

 ET

 " HIGH/LOW " : 

Appuyer sur le bouton "ON/OFF". 

MODE "AUT

O / OFF" : Régler le thermostat à la baisse ou éteignez le.

Utilisation avec granules  - le bois, le maïs, le blé, & l'orge seulement. Utiliser seulement lorsque les 

portes avants et la porte du réceptacle de cendre sont fermées. Si une ou des vitres devaient être 

remplacées, utilisez seulement du verre céramique. Les composantes requises pour l'installation: 

une rêvetement de cheminée reprisé en acier inoxydable 4”.

16622

Sidewall to center of unit (

De la paroi au centre de l'unité) 

24” (610 mm)

Sidewall to surround panel (De la paroi à l'entoure le panneau) 

2” (51 mm)

Bottom of unit to an unshielded 12” (305 mm) mantle 

 

(Le fond de l'unité à un manteau de cheminée non blindé) 

33“ (838 mm)

Unit to top facing (protruding ¾” [19 mm]) 

 (

De l'unité au sommet du parement)

 

0” (0 mm)

Unit to side facing (protruding ¾” [19 mm]) (

De l'unité au côté du parement)

 

0” (0 mm)

From door opening of unit to edge of floor protection 

 

(De la porte ouvrant au devant de protection de plancher) 

6” (152 mm)

From side of unit to edge of floor protection 

 

(De l'ouverture de porte pour prendre parti de protection de plancher) 

6

” (152 mm)

C

A

E

B

D

Adjacent  wall

G

F

Combustible floors must be protected 

by a non-combustible material. 

- See Owners Manual. 

Le plancher combustible doit être 

protégé par un matériel incombustible. 

- Consultez le manual.

INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE 

COMME UN MODELE SUR PIED DE POELE.

Minimum clearances to combustible materials./ Les dégagements minimums aux 

matériels combustibles:



Hampton GCI60 Cast Pellet Insert Technical Manual

6

Содержание GCI60

Страница 1: ...ervice agency FOR YOUR SAFETY Do not store or use gasoline or other flammable vapoursandliquidsinthevicinityofthisoranyother appliance Installation and service must be performed by an authorized insta...

Страница 2: ...result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your...

Страница 3: ...on 11 Exhaust And Fresh Air Intake Locations 11 Masonry Fireplace Installation 12 Positive Flue Connection 13 Built In Installation 14 Horizontal Exhaust Through Wall Installation 15 Through Wall With...

Страница 4: ...until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and...

Страница 5: ...buting plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR This uni...

Страница 6: ...d Fans will drop down to the LOW setting until the thermostat contacts close again AUTO OFF MODE Requires a thermostat When the thermostat contacts close the unit will light automatically Once up to t...

Страница 7: ...ps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg hr Testing Standard Weight with full hopper Consumption on High ASTM 1509 04 370 lb 167 8 Kg 6 5 l...

Страница 8: ...ted to all units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space Combustion air may be obta...

Страница 9: ...sonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace 5 Adjust the top anchor bo...

Страница 10: ...ling the Oversize Filler Panel 50 W x 38 H do so before sliding unit into place 2 Secure the filler panel to the backside of the cast faceplate using the 10 x 8 32 x 3 8 Thread Rolling Screws 8 32 x 3...

Страница 11: ...au de chemin e non blind 33 838 mm D Unit to top facing protruding 19 mm De l unit au sommet du parement 0 0 mm E Unit to side facing protruding 19 mm De l unit au c t du parement 0 0 mm F From door o...

Страница 12: ...terior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plant...

Страница 13: ...and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The...

Страница 14: ...y to permanently seal any opening between the masonry of the fireplace and the facing masonry Figure 9 Masonry fireplace installation When installing the insert into a masonry fireplace DO NOT remove...

Страница 15: ...ntering the chimney which will affect proper drafting of appliance Figure 10 Masonry fireplace positive flue installation A qualified installer should evaluate the existing fireplace to determine the...

Страница 16: ...er of tile The air space must be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L venting and be installed with...

Страница 17: ...nd the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe to the unit s starter pi...

Страница 18: ...e 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section of vent pipe Clean out tee...

Страница 19: ...tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble a...

Страница 20: ...ystem must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is a minimum of 24 61 cm above the roof NOTE...

Страница 21: ...f after long periods of burning the fire builds up or there is a build up of clinkers this would be a sign that the fuel quality is poor this requires more air The easiest way to make sure that an eff...

Страница 22: ...g unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still does not start contact y...

Страница 23: ...ton 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT If the Auger gear box does not turn but the m...

Страница 24: ...make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn pot liner the fire is goin...

Страница 25: ...e White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black White Green Ground 120V G...

Страница 26: ...XHAUST MOTOR CAPACITOR C W STRAP GC60 017 16 AGITATOR DRIVE SHAFT W SPROCKET GC60 008 17 MOTOR DRIVE SPROCKET GC60 009 18 AUGER MOTOR 1 RPM GF55 001 19 GCI60 COMBUSTION BLOWER W HOUSING MOUNT GASKET G...

Страница 27: ...IREBOX LINER GCI60 006 50 PED ASHPAN GASKET 10 GF55 020 51 ASH PAN GCI60 007 52 7 INCH DRAWER SLIDES SET OF 2 GCI60 008 53 22 INCH DRAWER SLIDES SET OF 2 GCI60 009 54 BEARINGS WITH MOUNTING BOLTS SET...

Страница 28: ...ide Right CHARCOAL GCI60 231 68 GCI60 Cast Ash Door CHARCOAL GCI60 241 69 GCI60 Cast Surround Left CHARCOAL GCI60 251 70 GCI60 Cast Surround Right CHARCOAL GCI60 261 71 GCI60 Cast Surround Top Left CH...

Страница 29: ...Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37 Hampton GCI60 Cast Pellet Insert Technical Manual 29...

Страница 30: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 71 72 73 Hampton GCI60 Cast Pellet Insert Technical Manual 30...

Страница 31: ...nty FPI covers the Burn Pot Liner against defects in materials and workmanship for part repair or replacement for the first three 3 years and limited labour for the first two 2 years to the original p...

Страница 32: ...before installation 10 FPI will not be responsible for inadequate performance caused by environmental conditions 11 The Limited Warranty does not cover installation and operational related problems s...

Страница 33: ...will be covered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 FPI is not liable for freight or labour on...

Страница 34: ...___________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ________________________...

Страница 35: ...__________________________________ Installer ___________________________________________________________ Phone ___________________________________________________________ Date Installed ______________...

Отзывы: