Installation
C
LEARANCES
TO
C
OMBUSTIBLES
:
Figure 4: GCI60 Clearance to Combustibles.
T
HERMOSTAT
I
NSTALLATION
:
1. Install the wall thermostat (millivolt rated thermostat
recommended, or a 12/24 Volt rated thermostat set to
millivolts) in a location that is not too close to the unit
but will effectively heat the desired area.
2. Connect the Thermostat or Timer to the thermostat
wires on the unit. (Fig. 5)
If the heat in the room becomes too great, the high limit
switch may turn the stove off and the switch will have to
be manually reset. To reset the high limit switch:
-open the hopper lid
-remove plug under control panel
-use screwdriver to press down on the button on top of
the snap disk switch
Figure 5: Thermostat connection wires.
A
Sidewall to center of unit (
De la paroi au centre de l'unité)
24” (610 mm)
B
Sidewall to surround panel (De la paroi à l'entoure le panneau)
2” (51 mm)
C
Bottom of unit to an unshielded 12” (305 mm) mantle
(Le fond de l'unité à un manteau de cheminée non blindé)
33“ (838 mm)
D
Unit to top facing (protruding ¾” [19 mm])
(
De l'unité au sommet du parement)
0” (0 mm)
E
Unit to side facing (protruding ¾” [19 mm]) (
De l'unité au côté du parement)
0” (0 mm)
F
From door opening of unit to edge of floor protection
(De la porte ouvrant au devant de protection de plancher)
6” (152 mm)
G
From side of unit to edge of floor protection
(De l'ouverture de porte pour prendre parti de protection de plancher)
6
” (152 mm)
C
A
E
B
D
Adjacent w
all
G
F
Combustible floors must be protected
by a non-combustible material.
- See Owners Manual.
Le plancher combustible doit être
protégé par un matériel incombustible.
- Consultez le manual.
INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE
COMME UN MODELE SUR PIED DE POELE.
Minimum clearances to combustible materials./ Les dégagements minimums aux
matériels combustibles:
These dimensions are minimum clearances.
It is recommended that you ensure
sufficient room for servicing, routine
cleaning and maintenance.
The unit must be installed with a minimum
of 6” (152 mm) of
fl
oor protection in front
of and to the sides of the door opening.
Hampton GCI60 Cast Pellet Insert Technical Manual
11