background image

Pre-Installation (continued)

DUAL MOUNTING INSTRUCTIONS

DUAL MOUNTING INSTRUCTIONS

7

This ceiling fan is supplied with two types of hanging assemblies: the 
standard ceiling installation using the downrod with ball and socket 
mounting, and the "close-to-ceiling" mounting. The "close-to-ceiling" 
mounting is recommended in rooms with less than 8 ft. ceilings or in 
areas where additional space is desired from the floor to
the fan blades.

When using the standard downrod installation, the distance from the 
ceiling to the bottom of the fan blades will be approximately 12 in. The 
"close-to-ceiling" installation reduces the distance from the ceiling to the 
bottom of the fan blades to approximately 9 in.

Once you have decided which ceiling installation you will use, refer to the 
corresponding sections and procedures during the assembly period.  
Where necessary, each section of the instructions will note the different 
procedures to follow for the two types of installation.

Standard Ceiling Mounting

Close-to-Ceiling Mounting

HAMPTONBAY.COM

Please contact 1-855-HD-HAMPTON for further assistance.

Содержание CARROLTON II

Страница 1: ...NG FAN THANK YOU THANK YOU Item 1000044890 Model AM215 ORB HAMPTONBAY COM 1 855 HD HAMPTON Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST...

Страница 2: ...nting Instruction Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 9 10 11 14 16 Operat...

Страница 3: ...lades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 8 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the ou...

Страница 4: ...ditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected fro...

Страница 5: ...sembled Blade arm screw with lock washer preassembled Light kit mounting screws preassembled Plastic nut preassembled Glass cap preassembled Decorative nut preassembled Pull chains and fobs not to sca...

Страница 6: ...lades Blade arms 14 watt LED Light kit Glass shade Pre Installation continued 6 Part Part A B C D E Quantity Quantity 1 1 1 1 1 Quantity Quantity 1 5 5 1 1 Description Description Mounting bracket pre...

Страница 7: ...he standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to th...

Страница 8: ...three different ways to mount the outlet box NN not included WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using...

Страница 9: ...rough the holes in the collar and the hanger ball downrod assembly E Be careful not to jam the clevis pin CC against the wiring inside the hanger ball downrod assembly E Insert the clevis pin CC throu...

Страница 10: ...wires exiting from the top of the fan motor assembly F through the canopy ring B Make sure the slot openings of the canopy ring B are on top and then proceed to place the canopy ring B and canopy C o...

Страница 11: ...or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of the hanger ball E Failure to pro...

Страница 12: ...bly E When using close to ceiling mounting there is only one green ground lead from the mounting bracket A since the hanger ball downrod assembly E is not used Connect the fan motor white wire to the...

Страница 13: ...d firmly tightened WARNING Make sure the tab on the mounting bracket A properly sits in the groove in the hanger ball E before attaching the canopy C to the mounting bracket A by turning the canopy ho...

Страница 14: ...G engages in the spring locking mechanism SS Make sure the spring of the spring locking mechanism SS is upward and the butt of the spring locking mechanism SS is against the edge of the blade NOTE Yo...

Страница 15: ...fan Do no insert foreign objects between rotating fan blades G Fasten the blade assemblies to the fan motor assembly F by lining up the slots of the motor TT with the tabs on the blade arms UU Tighte...

Страница 16: ...breaker or removing the fuse at the fuse box Turning power off using the fan switch is not sufficient to prevent electric shock 12Mounting the glass shade Remove the plastic nut II glass cap JJ and d...

Страница 17: ...eep the light kit for future use Attach the plastic plug MM to the switch housing cover WW Install the switch housing cover WW to the switch housing with light kit mounting screws HH provided 13 Insta...

Страница 18: ...ize ceiling height and number of fans To turn the light kit ON or OFF pull the chain that is attached to the light kit I REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The...

Страница 19: ...motor The motor has permanently lubricated sealed ball bearings Do not Do not WARNING Make sure the power is off at the electrical panel box before you attempt any repairs Refer to the section Making...

Страница 20: ...g above the tip of one of the blades then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repea...

Страница 21: ...ion Plastic wire nut Canopy mounting screw with lock washer preassembled Clevis pin preassembled Cotter pin preassembled Collar setscrews preassembled Collar mounting screws with lock washers preassem...

Страница 22: ...etain this manual for future use AM215ORB0002 A 1 855 HD HAMPTON Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay...

Отзывы: