3 HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Warranty
LIMITED LIFETIME WARRANTY
WHAT IS COVERED
If this product fails due to a defect in materials or workmanship at any time during the first THREE years of ownership, the manufacturer will replace it
free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn. This
warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty repair replacement parts to repair this fan.
Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied warranty, the above exclusions
and limitations may not apply. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair, replacement as well
as incidental and consequential damages connected with the above are excluded. Any damage to this product as a result of neglect, misuse, accident,
improper installation or use other than the purpose SHALL VOID THIS WARRANTY. Shipping costs for return product as part of a claim on the warranty must
be paid for by the customer.
Contact the Customer Service Team at 1-855-HD-HAMPTON or visit www.HAMPTONBAY.com.
Product Specifications
Airflow: 110 CFM
Power consumption: 32 W
120 V, 60 Hz
Weight: 10.3 lbs.
Duct diameter: 4 in.
Ceiling Opening Dimension Requirements:
10.82 in. (L) x 10.5 in. (W) x 8.5 in. (H)
Sound output: 1.0 Sones
Typical Installation
The ducting from this fan to the outside of the building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest, straightest duct routing possible for best
performance, and avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing
ducts may not achieve their rated air flow.
Do not install ventilation fan in areas where the duct work will require configuration as shown.
Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to
create an air-tight path and to minimize building heat loss and gain and reduce the potential
for condensation.
Place/wrap insulation around duct and/or fan to in order to minimize possible condensation
buildup within the duct, building heat loss and gain.
Turning angle too sharp
Fan
body
Minimum 18"
Avoid duct shrink
Too many elbows
Elbow near the body
RECOMMENDED
Fan housing
Duct
Roof cap
Eave vent
Wall cap
Eave
Roof
Wall
Fan housing
Duct
Fan housing
Duct