background image

3

WARNING:

 Fire table is for outdoor use only.

Important Safety Information 

IMPORTANT NOTICE

Read and understand all warnings and precautions prior to assembly and use of your gas fire table. Improper installation, adjustment, 

alteration, service or maintenance can cause injury or property damage. 
The installation of this unit must adhere to local codes or either the National Fuel Gas Code, ANSI Z223. 1/NFPA54 or CAN/CGA-B149.1

Natural Gas and Propane Installation Code. 

Minimum Clearance from Unit to Combustible Materials:

61 ft. (155.4 cm) from the top; 48 ft. (121.9 cm) from all sides and back. Do not locate this fire table under any overhead enclosure. 

IF YOU SMELL GAS

    Shut off gas supply to the fire table.

    Extinguish any open flame.

    Do not try lighting any appliance.
    Do not touch any electrical switch; do not use any phone in your building.
    Immediately call your gas supplier from a neighbor's phone.
    Follow the gas supplier’s instructions.
    If you cannot reach your gas supplier, call the fire department.

     Keep these instructions for future reference. If you are assembling this unit for someone else, give this manual to him or her to read 

    and keep for future reference.
    This gas fire table must be used ONLY outdoors in a well-ventilated space and shall NOT be used inside a building, garage, or

    any other enclosed area.
    DO NOT use this outdoor gas fire table for indoor heating. TOXIC carbon monoxide fumes can accumulate and cause asphyxiation.
    NEVER LEAVE this gas fire table unattended when in use.
    This unit is to be used with propane gas only! (sold separately)
    Do not attach a remote gas supply to this unit.
    Only use propane gas for this unit.
    Converting this unit to natural gas is dangerous. This conversion kit shall be installed by a qualified service agency in accordance with 

    the manufacturer's instructions and all applicable codes and requirements of the Authority having jurisdiction. The maximum inlet natural 

    gas pressure for this outdoor fire table is 10 1/2 in. wc; the minimum inlet natural gas for this outdoor fire table is 3 1/2 in. wc

    Do not use a flame to check for gas leaks.
    Do not store or use gasoline or other flammable vapors and liquids within 25 ft. (7.62 m) of this or any other appliance.
    Do not store any combustible materials in the base enclosure.

Children and adults should be alerted to the hazards of high surface temperatures and be kept at a safe distance while fire table is in 

use. This outdoor fire table is not to be operated by children. Young children should be closely supervised when in the vicinity of this 

outdoor fire table. Do not hang or place clothing or other flammable materials on or near the gas fire table. Any guard or protective 

device removed for servicing the appliance shall be replaced prior to operating the appliance.

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually 

by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartment, 

burners and circulating air passageways of the appliance are kept clean.

HAMPTONBAY.COM

Please contact 1-855-HD-HAMPTON for further assistance.

WARNING: 

Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, 

or in a fire or an explosion causing damage to property. 

Содержание BOWBRIDGE STEEL LP FIRTPIT FHTS80166

Страница 1: ...ucts designed to enhance your home Visit us online to see our full line of products available for your home improvements needs Thank you for choosing Hampton Bay BOWBRIDGE STEEL LP FIRTPIT Questions p...

Страница 2: ...on and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference If you are asse...

Страница 3: ...te gas supply to this unit Only use propane gas for this unit Converting this unit to natural gas is dangerous This conversion kit shall be installed by a qualified service agency in accordance with t...

Страница 4: ...e table when in use will become too hot to touch Do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders or heat resistant gloves or mi...

Страница 5: ...NOT store in a building garage or any other enclosed area Never store your LP gas tank where temperatures can reach over 125 F 52 C Do not store the LP gas cylinder in direct sunlight or near a source...

Страница 6: ...replacement of the hose call the service center at 1 855 HD HAMPTON Use only replacement parts from the manufacturer b Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when...

Страница 7: ...oard HARDWARE INCLUDED NOTE More than one person may be required to assemble this product NOTE Hardware not shown to actual size M6X15 Combination bolt M6X12 Countersunk bolt 22 1 1 1 AA AA BB BB Plas...

Страница 8: ...ort Lava Rocks Burner Bowl 1 1 1 I I J J K K Burner ring 1 L L Pilot housing Manual Electric lgniter Control Knob 1 1 1 M M N N O O Regulator Hose 1 P P Part Description Quantity WARNING Failure to po...

Страница 9: ...table top B using M6X15 combination bolts AA Do not tighten the bolts at this step NOTE Pay attention to the direction of control knob it must place as below direction shown HAMPTONBAY COM Please con...

Страница 10: ...inued 2 CONNECTING THE SIDE PANEL Attach the side panel F to the table top B using M6X15 combination bolts AA Do not tighten the bolts at this step C D E E F AA NOTE Loosely tighten all the bolts usin...

Страница 11: ...BE Attach the limit tube H to the leg C D using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tigh...

Страница 12: ...Attach the tank support I to the leg C D E using M6X15 combination bolts AA Do not tighten the bolts at this step HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Loosely tig...

Страница 13: ...ttach the door G to the leg C using an M6X12 countersunk bolt BB and plastic washers CC as shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance NOTE Tighten all the bolts...

Страница 14: ...14 Assembly continued 6 ATTACH THE KNOB TO THE DOOR Attach the knob DD to the door C shown below HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance C DD...

Страница 15: ...n place fully tighten all the bolts using the hex wrench EE Place the lava rocks J into the burner bowl K HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance CAUTION To ensure proper...

Страница 16: ...to burner bowl until it has cooled down HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance A B Make sure to remove the burner lid before lighting WARNING Surfaces on the fire table...

Страница 17: ...D CONTROL KNOB Insert the AAA battery FF and control knob N into the manual electric igniter N and twist the button cover on to igniter housing Do not over tighten HAMPTONBAY COM Please contact 1 855...

Страница 18: ...etainer bolt by turning counter clockwise on CAUTION LP gas tank must be properly disconnected and removed prior to moving this Secure tank by turning LP gas tank retainer bolt clockwise until tight H...

Страница 19: ...there is no debris caught in the head of the LP gas tank head of the regulator valve or in the head of the burner ports Connect the regulator hose assembly to tank by turning knob clockwise until it s...

Страница 20: ...ve is CLOSED Disconnect regulator hose assembly from LP gas by turning knob conter clockwise until it is loose Place the protective cap cover on the LP gas tank and store it outdoors in a well ventila...

Страница 21: ...proper installation Make sure the regulator hose and valve connections are securely fastened to the burner and the tank Failure to follow those instructions can serious injury or property cause death...

Страница 22: ...ANK SECTION Turn LP gas tank valve to OPEN a If any bubbles appear turn LP gas tank valve to CLOSED reconnect and re test b If you continue to see bubbles after several attempts turn LP gas tank valve...

Страница 23: ...23 Operation continued 7 CLOSE THE DOOR Close the door Now the fire table is complete and ready to use HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance...

Страница 24: ...3 Control knob must be in the OFF position 4 To ensure proper function the screen on the pilot housing should not be covered by lava rocks 5 Connect LP gas tank per steps 1 and 2 in the Operation sec...

Страница 25: ...ble Before Each Use 1 Ensure the outdoor fire table area is clear and free from any combustible materials gasoline and other flammable vapors and liquids 2 Do not obstruct the flow of the combustion o...

Страница 26: ...remains the customer s responsibility for freight and packaging charges to and from our service center This warranty does not cover commercial use hardware acts of nature fire freezing and abusive us...

Страница 27: ...5 minutes for gas to clear 3 Follow Checking for Leaks section There is no gas flow The coupling nut and regulator are not fully connected An obstruction of the gas flow 1 Clear the burner venturi tub...

Страница 28: ...en burning in cold weather temperature below 50 F 10 C Ice has built up on the outside of the LP gas tank because the vaporization process is too slow 1 Turn off per Turning Off section 2 Replace with...

Страница 29: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Отзывы: