Troubleshooting
An irregular flame
pattern flame
does not run
the full length
of burner.
No gas flow.
Exchange, refill or replace LP gas tank.
The Flame is yellow
or orange.
New burner may have residual
manufacturing oils.
Burn the outdoor fire table for 15 minutes and reinspect.
Spider webs or insect nest are in
the burner/venturi tube.
Clean the burner/venturi tube.
Poor alignment of valve to
burner/venturi tube.
Ensure the burner/venturi tube is properly engaged with valve .
A flashback (fire
in venturi/
burner tube(s)).
The urner and/or burner/
venturi tube is blocked.
Clean the burner and/or burner/venturi tube.
The flame goes out.
High or gusting winds.
Do not use outdoor fire table in high winds.
Low on LP gas.
Exchange, refill or replace LP gas tank.
Excess flow valve tripped.
Refer to “Sudden drop in gas flow or reduced flame height”.
The flame seems to
lose heat when
burning in cold
weather —
temperature below
50°F (10°C).
Ice has built up on the outside of
the LP gas tank because the
vaporization process is too slow.
1. Turn off per “Turning Off” section.
2. Replace with a spare LP gas tank.
3. Reconnect LP gas tank per “Installing LP Gas Tank” section.
4. Follow “Checking for Leaks” section.
5. Light outdoor fire table per “Lighting” section.
There is a sudden
drop in gas flow,
or the flame height
is reduced.
Out of gas.
Overfilling prevention device
may have been activated.
Exchange, refill or replace LP gas tank
1. Turn
control knob
to “OFF”.
2. Wait 30 seconds and light outdoor fire table per “Lighting” section.
3. If flames are still too low, reset the overfilling prevention device:
a. Turn
control knob
to “OFF”.
b. Turn LP gas tank valve to “CLOSED”.
c. Disconnect regulator.
d. Turn
control knob
to “ON”.
e. Wait one minute.
f. Turn
control knob
to “OFF”.
g. Reconnect regulator and leak check connections, being
careful not to fully open valve.
h. Light outdoor fire table per “Lighting” section.
HAMPTONBAY.COM