PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Main burner will
not light
Gas valve may be off
Turn gas valve ON
Fuel tank may be empty
Air in supply system
Purge air from lines pen gas lines and depress control knob
for 2-3 minutes.
Loose connection
Igniter fails
Use stick lighter to manually light
Gas pressure low with valve open full
Replace cylinder or regulator
New cylinder or 1st ignition
Purge air from lines
Replace hose/regulator assembly
Pressure is low
Replace LPG tank
Tank is low on fuel
Fill LPG tank
Gas hose is kinked
Check and straighten or replace
Burner unit
Clean components as needed
Thick black smoke
Blockage in burner assembly—thoroughly clean burner
TROUBLESHOOTING
14
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.