background image

2

Table of Contents

Operation-Fan .............................................................

Pull Chain Operating Instructions ..........................................

Care and Cleaning-Misting Device ...........................

Troubleshooting -Fan .................................................

Operation-Misting Device ..........................................

Care and Cleaning-Fan ..............................................

Troubleshooting - Fan.................................................

Service Parts ...............................................................

20
20

21

22

23

24

25

26

Table of Contents ..........................................................

Safety Information .........................................................

Warranty .........................................................................

Pre-installation ..............................................................

Specifications ..........................................................................
Tools Required .........................................................................
Hardware Included ..................................................................
Package Contents ....................................................................

Installation .....................................................................

Assembly ........................................................................

Hanging the Fan .....................................................................
Attaching the Fan Blades .......................................................

Safety Information-Misting Device ............................

Attaching the Misting Device 

...........................................

Installing the Water Lines ......................................................
Water Connection at Source ..................................................
Pump Installation Wall ...........................................................
Water Connection at Pump ....................................................
Power Connection Cord .........................................................

2

3

4

4
4
4
5
6

7

8

10
13

15

16
16
17
17
18
19

READ AND SAVE THESE INSTRUCTIONS

Содержание 1005 131 413

Страница 1: ...rning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service Item 1005 131 413 Model YG188M NI Visual instruction of how to install this fan Visit www homedepot com and enter either the Item or Model number to find this fan and click the link of visual instruction in the product overview section ...

Страница 2: ...ts Safety Information Warranty Pre installation Specifications Tools Required Hardware Included Package Contents Installation Assembly Hanging the Fan Attaching the Fan Blades Safety Information Misting Device Attaching the Misting Device Installing the Water Lines Water Connection at Source Pump Installation Wall Water Connection at Pump Power Connection Cord 2 3 4 4 4 4 5 6 7 8 10 13 15 16 16 17...

Страница 3: ...y dust cloth or lightly dampened cloth will be suitable for most cleaning 8 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 9 All setsc...

Страница 4: ...es is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unautho...

Страница 5: ...nting screw not to scale Pull chain and fob not to scale 7 Ft water tube not to scale 25 Ft water tube not to scale Two way connector not to scale Spigot hose connector not to scale Tube clip not to scale Tube clip mounting screw wall anchor not to scale Tube clip mounting screw not to scale Pump mounting screw wall anchor not to scale Pump mounting screw not to scale Part Part Description Descrip...

Страница 6: ...t A B C D E Quantity Quantity 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy Hanger ball downrod assembly Misting ring cover Misting ring C 12 in and 24 in longer downrods are available please call Hampton Bay Customer Service PACKAGE CONTENTS PACKAGE CONTENTS Pre Installation continued 6 H I F J G A E B C D ...

Страница 7: ...t included directly to the building structure Use appropriate fasteners and materials not included The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box not included Outlet Box Outlet Box Hanger Bar Outlet Box Recessed Outlet Box Ceiling Moun...

Страница 8: ...py B from the mounting bracket A by turning the canopy B counterclockwise Remove the cotter pin NN and clevis pin OO and loosen the two collar setscrews PP from the motor collar Take out the setscrew QQ located in the hanger ball RR lower the hanger ball RR and remove the cross pin SS Remove the hanger ball RR from the hanger ball downrod assembly C Remove the ground lead TT from the downrod assem...

Страница 9: ...ownrod bottom and collar then insert the clevis pin OO through all holes of the downrod and collar be careful not to jam any wires or tubes inside the downrod Restore the cotter pin NN to the end of the clevis pin OO make sure it snaps into the lock position then tighten the two collar setscrews PP Secure and tighten the misting ring E onto the motor with two mounting screws BB and ensure all scre...

Страница 10: ...tor assembly F up to the mounting bracket A and seat the hanger ball down rod assembly C in the mounting bracket A socket Make sure the tab on the mounting bracket A socket is properly seated in the groove in the hanger ball downrod assembly C This will help to balance the ceiling fan WARNING To reduce the risk of fire electric shock or other personal injury mount the fan only to an outlet box or ...

Страница 11: ... the fan motor black wire and the blue wire to the supply black hot wire using a plastic wire nut AA Turn the wire nut connections upward spreading them apart so the green ground and white wires will be on one side of the outlet box and the black and blue wires will be on the other side and push carefully up into the outlet box You can cut or remove excess wire if necessary WARNING To avoid possib...

Страница 12: ...til it drops into place XX XX A B UU A B UU WW NOTE The canopy has two mounting orientations at 180 apart Select the orientation that points the tube in the direction best for routing to the pump Remove the rubber leak prevention washer WW from the canopy B Carefully feed the water tube UU into the hole of the rubber leak prevention washer WW Carefully attach the rubber leak prevention washer WW i...

Страница 13: ...ith the blade arm posts AAA and press the blade down firmly Ensure the key slot holes ZZ are properly seated on the blade arm posts AAA Firmly slide the blade G away from the blade arm H until the blade G engages in the spring locking mechanism BBB Make sure the spring of the spring locking mechanism BBB is upward and the butt of the spring locking mechanism BBB is against the edge of the blade To...

Страница 14: ...balancing the blades G or cleaning the fan Do no insert foreign objects between rotating fan blades G Fasten the blade assemblies to the fan motor assembly F by lining up the slots CCC of the motor F with the tabs DDD on the blade arms H Tighten the two blade arm screws with lock washers EEE already installed in the blade arms H Repeat this procedure for the remaining blade arms H EEE DDD 14 ...

Страница 15: ...above the water spigot or reservoir 7 Pump must be installed at a vertical distance 8 ft from the fan 8 Tubing needs to be crimp free Nothing can be put on top of the tubing which can cause damage or prevent water flow Do not route in a way that tubing can be stepped on 9 If direct connection is not available water may be drawn from a reservoir not included and an in line filter sold separately is...

Страница 16: ... to ceiling with tube clips HH and tube clip mounting screws and anchors JJ and II If removal of the water lines from a two way connector is required for any reason depress the rings FFF While pulling out the tubes do not pull out tubes without depressing rings as this can cause damage to the connector Before starting installation disconnect the power by turning off the circuit breaker or removing...

Страница 17: ...secure ring GGG from the hose connector GG and attach the 7 ft water tube EE into the faucet connector GG Reinstall the fixed secure ring GGG Attach the hose connector GG to the hose spigot HHH To separate the hose water tube EE you MUST PRESS DOWN the FIXED RING FFF on the bottom of the faucet connector GG The pump should be installed at a level higher than the water supply and less than 8 ft ver...

Страница 18: ... rings FFF on the bottom of the pump I and pull out the plastic plugs III Attach the 7 Ft water tube DD and 25 Ft water tube EE into the pump I To separate the water tubes DD and EE you MUST PUSH DOWN the FIXED RING FFF on bottom of the pump I DD I III III EE FFF 18 WATER OUT WATER IN DC 24V 1 5A Bottom View ...

Страница 19: ...Device continued 15 Connecting the power cord Plug the power cord J into a 120v outlet Once you restore power to the house the misting device is ready to use J 19 HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance ...

Страница 20: ...e reversing the direction of the blade rotation NOTE Not recommended to use misting feature with fan in reverse REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing This switch controls directions forward switch down or reverse switch up Warm weather Counterclockwise Direction A downward air flow creates a co...

Страница 21: ...nditions Using the misting feature in very high humidity will aid in cooling but water build up on surfaces below the fan is possible At a distance from the fan you may experience light droplets of water This is normal to operation and can be minimized by increasing the fan speed As with any misting system the conditions of the environment such as temperature wind humidity and proximity to the fan...

Страница 22: ...N OPERATION RESERVOIR DRAWN OPERATION If connecting to a hose spigot or plumbed water supply is not an option it is possible to use a water reservoir not included The reservoir needs to be clean free from debris and preferably have a lid that prevents air born contaminants from entering The reservoir also must be emptied after each use to prevent stale water and or algae from entering the mist sys...

Страница 23: ...nstall the mist ring cover MMM being sure it aligns with the tabs PPP on the mist ring cover MMM and misting ring E If cleaning does not help replacement nozzles are available Call Customer Service 1 855 HD HAMPTON to order the replacement nozzles NNN QQQ RRR SSS WINTERIZING WINTERIZING If the fan is installed in a location that will experience below freezing temperatures the mist system must be w...

Страница 24: ...e ceiling to the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box The fan will not start The fan sounds noisy Troubleshooting Fan Care and Cleaning Fan Check the support connections brackets and blade attachments twice a year Make sure they are secure Because of the fan s natural movement some ...

Страница 25: ...s then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same point from the ceiling for every blade Measurement deviations should be within 1 8 in If all deviations are less than 1 8 in and the fan continues to wobble please call Customer Service 1 855 HD HAMPTON...

Страница 26: ...lastic wire nut Misting ring mounting screw Part Part CC DD EE FF GG HH II JJ KK LL NNN Description Description Pull chain and fob 7 Ft water tube 25 Ft water tube Two way connector Spigot hose connector Tube clip Tube clip mounting screw wall anchor Tube clip mounting screw Pump mounting screw wall anchor Pump mounting screw Nozzle Service Parts A G I H J D E F B C AA CC DD EE FF GG BB HH II JJ K...

Страница 27: ... HAMPTON HAMPTONBAY COM Retain this manual for future use Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service ...

Отзывы: