RESET
Press and hold “UP” and “DOWN”
simultaneously more than 3 seconds.
Legs begin to move down at a half speed of
normal operation.
Keep pressing “UP” and “DOWN”.
Legs move down to the lowest position and
rebound 2-5 mm, then stop.
Release “UP” and “DOWN” together.
Initialization is completed.
UP
Down
The system can be operated normally now. Press and hold the “UP” or “DOWN” button to move the system
to the desired height.The system stops when you release the buttons.
The initialization procedure must be completed.
VXMKA EN
20
RESET obligations prior to initial operation
VXMKA
Stand 09/2020 / englisch 114415 MNMONT_XMKA _RESET WEEE-Reg.-Nr. DE 34853279
Before initial operation the table
• must be in the correct position,
• the control unit with the "Gyrosensor" must be in a horizontal position and screwed tight according to
the assembly instructions,
• the power must be connected,
• a reference drive "RESET" must be carried out on the table.
Before each use, make sure that neither objects, persons nor animals are in the way of the height
adjustment.
If it is necessary to disconnect the cables from the motor or the control unit, always disconnect the power
supply unit from the electricity supply beforehand.
If at any time the rack should no longer function properly, always carry out
a "RESET
" fi rst.
Please repeat the RESET at regular intervals, e.g. 1x per month!
After longer operation of the table it is possible for slight lift diff erences to occur
between the columns (the table is slightly ‘tilted’). This diff erence in height is
resolved by carrying out a RESET drive.
The reset must be carried out before the fi rst operation, after installation of the tab-
le or after replacement of parts.
RESET-m
ode
The fi rst time you put in the plug of the power supply into the socket, the height adjustment can only be
operated in the reset-mode.
As long as the reset-mode is enabled, the system can only move downward. To end the reset-mode and use
the system normally, please follow the next steps: