XDSM
56
8. Troubleshooting
The following is valid in principle for troubleshooting:
Check whether the desk has been operated in accordance with the operating instructions.
It is often possible to find the error here and resolve it.
Always observe the safety instructions listed in the operating instruction.
Contact with electricity can lead to serious injury from electric shock.
• Only disconnect plug connectors when disconnected from the power.
• Metal parts on the desk can be electrified if there is damage to power cable and
connections.
8.1 Error codes
Various errors are displayed as code on the illuminated display of the operating panel:
Number: Description:
Resolution:
HOT
The control monitors the duty cycle
and its maximum temperature. A
value was exceeded Internal Error
M1
Wait until the ‘hot’ display goes out. Then operate the
table correctly again
E00
Internal Error Channel 1
Switch off the motor control and consult the customer
service department.
E01
Internal Error Channel 2
E02
Internal Error Channel 3
E12
Defect Channel 1
First switch off the motor control.
Either you then connect the correct motor to the
relevant jack, OR you resolve the external short circuit.
Then switch the motor controls back on.
E13
Defect Channel 2
E14
Defect Channel 3
E24
Excess Current motor M1
Remove the objects that are caught in the drive area.
If the table is overloaded
=> remove the load from the table.
Consult the customer service department.
E25
Excess Current motor M2
E26
Excess Current motor M3
E48
Excess Current motor group 1
E49
Excess Current motor group 2
E60
Collision protection
E62
Excess Current controls
E36
M1 not connected
Connect the correct motor to the affected jack.
Carry out the reset
E37
M2 not connected
E38
M3 not connected
E61
Motor exchanged
E55
Synchronisation of motor group 1
not possible
Remove the load from the table.
Carry out a reset;
Consult the customer service department if the error is
still displayed after the reset
E56
Synchronisation of motor group 2
not possible
E67
Voltage too high
Remove the power supply cable and consult with the
customer service department.
E81
Internal error
Carry out reset.
Remove the power supply cable and then re-insert it
after several seconds.
If this error occurs frequently then consult with the
customer service department and remove the power
supply cable
Содержание VXDSM
Страница 20: ...XDSM 20...
Страница 60: ...XDSM 60...