Anchor Procedure
1.
Place unit into position to be mounted and cycle unit to set its stance.
2.
Wearing protective glasses, drill down into flooring perpendicularly to the required depth, ensuring that the foot
thickness of the unit is being accounted for; refer to
Anchor Specifications
and
Foot Dimensions
.
NOTE:
Use 3/8" size bit for Imperial anchors and 10mm for Metric anchors.
Item
Description
Qty.
1
Drill with Concrete Bit
1
2
Upright
1
3.
Clear out debris from hole.
4.
NOTE:
This step only applies to dynamic anchors. Do not hammer static anchors.
Insert anchor assembly and hammer until flush against upright's base plate.
Item
Description
Qty.
1
Hammer
1
2
Anchor Assembly
1
3
Base Plate
1
Page 53 of 55