background image

FIREBOX LININGS & THROAT
PLATE

The Hero Deluxe multifuel stoves firebox have
reflective liners to the sides and rear and a
specially shaped throat plate which sits on the
liners. If these are not in place please refer to page
15 to install these.

WOOD/MULTIFUEL GRATE  

The Wood/Mulitfuel grate should remain in the fire
when burning fuel at all times. If cleaning is
required carefully take the grate out and clean as
necessary. 

Note:

It may be necessary to remove the

throat plate and liners to remove the grate.

AIR INLET CONTROLS

Hero Deluxe multifuel stoves have two air inlets:
•The air wash system (so called because its
pre-heated high speed air washes across the inner
face of the door glass, keeping it clear), which
provides over draught, and
•The primary air inlet providing under draught to
the base of the fire chamber through the controls on
the doors of the fires.

PRIMARY AIRWASH

On the Hero Deluxe, primary air enters the
appliance through the controls on the bottom of the
fire doors. Moving the control knobs to the right
will increase the air inlet, to the left to reduce the air
inlet, or to seal the ash door completely. 

HAMLET AIRWASH SYSTEM  

The air wash has an internal sliding plate with slots,
housed in a cover plate, and is located above the fire
door. Sliding the control knob to the right as far as it
will go achieves the fully open position. Sliding it to
the left will shut off the air inlet slots as shown in 
Fig. 2a and Fig. 2b.

Fig. 2a Fully closed   

Fig. 2b Fully open

Even when all the slots are completely shut a
"bleed" of secondary air will be maintained
ensuring that inflammable gases are burnt off. 

DISASSEMBLE AIRWASH

The Hero Deluxe air wash may be disassembled for
cleaning or adjustment. To achieve this, the
following procedure should be followed:

This should only be carried out when the fire is cold
and unlit.

•Slide the control knob fully to the left (As in
Fig.2a) .
•Keeping this knob in the above position, unscrew
the spring outer handle and remove washer.
•Support airwash cover with one hand.
•Move cover up by smartly tapping the bottom with
a hammer or mallet.
•Remove cover from appliance.
•Clean the air inlet slots
•Refit using reverse procedure.

Note:

The airwash chamber (inside of stove) can be

completely removed from the stove by removing
two outer most pozi drive screws.

Fig. 3 Disassemble airwash 

OPERATING TOOL

Your Hamlet stove comes with a multi-purpose
tool, which is used for de-ashing and for emptying
the ash pan. (Fig. 4)

Fig. 4 Operating tool and ashpan

8

Hamlet Hero Deluxe Multifuel Stove

OPERATING INSTRUCTIONS  

 

Содержание Hero Deluxe

Страница 1: ...Hero Deluxe Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Hero Deluxe Multifuel Stove Rev 1 September 2004 Part No AFS1131...

Страница 2: ...ed which is why we are so confident in the reliability of our product Should you have any questions about our Hamlet Stoves that are not covered in this manual please contact the local dealer in your...

Страница 3: ...xtended Burning 11 12 Ash Removal 12 Over Firing 12 SERVICING Cleaning 12 Annual Maintenance 13 INSTALLATION Page General Precautions 14 Handling 14 Hearth 14 Combustible Materials 14 Firebox Liner Pa...

Страница 4: ...RNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE PART...

Страница 5: ...operly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of appliances...

Страница 6: ...S058 7 Operating tool 1 AFS008 8 Rear liners 1 AFS1143 9 Side liners 2 AFS1142 The model and Serial Number of your fire can be found stamped into the casing centrally just below the bottom edge of the...

Страница 7: ...onal Type O Height mm including legs 492 mm Width mm across canopy 405 mm Depth mm over ashlip 345 mm Height to centre of rear flue 395 mm Depth from back to centre of flue 105 mm Weight Kg Unpacked 4...

Страница 8: ...nternal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far as it will go achieves the fully open position Sliding it to th...

Страница 9: ...e inside of the door securing the retaining clips Carefully remove any pieces of broken glass and sealing gasket wearing suitable gloves Re place the gaskets and line them up in relation to the door f...

Страница 10: ...ney and the appliance and increase the risk of chimney fire Note If you have sticky tar inside the appliance or chimney your wood is Green or too wet Recommended Reading Wood as Fuel available from th...

Страница 11: ...se a fire lighter If using a gas poker be sure to remove it immediately the fire is alight When the fire is well alight regulate the burning rate by adjusting the setting on the primary air inlet cont...

Страница 12: ...rder to protect it so de ashing should cease as soon as the first red embers drop into the ash pan Further de ashing will cause heat build up under the grate which will considerably shorten its life T...

Страница 13: ...ut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glass may...

Страница 14: ...RTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project...

Страница 15: ...up The projecting lugs sit on top of the side liners The long centre tab on the back edge rests on the rear liners The shorter turn down tabs against the vertical face Note Neither the rear firebox li...

Страница 16: ...on fumes from the stove outlet to the outside air To ensure a good updraught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at t...

Страница 17: ...ment J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety odpm gov uk bregs brads htm Details on the...

Страница 18: ...18 Hamlet Hero Deluxe Multifuel Stove INSTALLATION...

Страница 19: ...NSULATED FLUES TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 A is minimum clearance for no...

Страница 20: ...or individual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless steel boilers eithe...

Страница 21: ...pipe from the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged FINAL CHECK Before handing over the installation to the customer it is strongly recommended that th...

Страница 22: ...ught gas appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been re...

Страница 23: ...08 AFS058 AFS009A 2 Throat Plate 3 Fuel Grate 5 Operating Tool 7 Ashpan 4 Flue Spigot Part Description Visual Aid not to scale Hamlet Hero Deluxe Part No 6 Fire Door Locking Assembly AFS1146 1 Main Do...

Страница 24: ...FS1144 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips with Gasket 13 Hinge kit Comprises 2 Hinges 4 Fixings Per Set 14 Hamlet Hardy Airwash Part Descriptio...

Страница 25: ...l Stove 25 SPARE PARTS 16 Feet Fixings AFS1153 AFS998 AFS1131 AFS101A 17 Hamlet Fire Gloves 18 Operating Manual 19 Anthracite Spray Paint Part Description Visual Aid not to scale Hamlet Hero Deluxe Pa...

Страница 26: ...anufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repair or replace it FREE OF CHARGE as long as the...

Страница 27: ...anual please contact your Hamlet retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart Ham...

Страница 28: ...ked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on page 22 of this manual If an add in boile...

Отзывы: