Document #101-0204
22
10/21/2011
Additional Wire Terminations For Use With The Credit
Card or Customer Value Card System.
The installation of the machine should proceed as outlined in the above section. However, if a Credit
Card or Customer Value Card System is being used, the following must be performed, as well.
•
A Cat 5 or 5E cable should be pulled to each HTK on the site. The
cable should be run from were the connection to the internet device
(router or switch) is located back to the HTK. When crimping Cat 5
or 5E cable consult an electrician or network person for proper attach-
ment.
NOTE: When running Cat 5 or 5E cable, the run should
be with out any splicing or mid point connections. If there are this
can lead to communication issues. The maximum length of a net-
work cable is 328 ft or 100 meters. If longer a switch must be used
to prevent communication issues.
•
The Cat 5 or 5E cable can be run in with the low voltage wires coming
from the car wash
Additional Wire Terminations For Use With A Hamilton
Code System or POS 4000
The installation of the machine should proceed as outlined in the above section. However, if a Hamilton
Code System or POS 4000 is being used, the following must be performed, as well.
•
A 485 communication line (A. 1 pair, twisted, shielded cable) should
be pulled to each HTK on the site. The cable should be run from were
the connection to the code system device (isolator box) is located back
to the HTK. The connection to the HTK is on a 2 position phoenix
connector located on the bottom side of the controller. Position 1 is the
positive and Position 2 is the negative.
NOTE: When running a 485 communication line, the run
should be made with out any splicing or mid point connections.
If there are this can lead to communication issues. The maximum
length of a 485 cable is 1000 ft.
•
The 485 communication can be run in with low voltage wires coming
from the car wash.
Содержание HTK
Страница 1: ...Document 101 0204 1 10 21 2011 HTK Installation Manual ...
Страница 7: ...Document 101 0204 7 10 21 2011 HTK Dimensions For brick in installation ...
Страница 8: ...Document 101 0204 8 10 21 2011 HTK Dimensions Free Standing installation ...
Страница 9: ...Document 101 0204 9 10 21 2011 Brick In Installation ...
Страница 12: ...Document 101 0204 12 10 21 2011 Free Standing Installation ...
Страница 14: ...Document 101 0204 14 10 21 2011 Access Control Lane Layout ...
Страница 19: ...Document 101 0204 19 10 21 2011 HTK Automatic Wiring ...
Страница 20: ...Document 101 0204 20 10 21 2011 HTK Gated Tunnel Wiring ...
Страница 26: ...Document 101 0204 26 10 21 2011 Power Supply ...
Страница 27: ...Document 101 0204 27 10 21 2011 Controller ...
Страница 28: ...Document 101 0204 28 10 21 2011 Distribution ...
Страница 29: ...Document 101 0204 29 10 21 2011 Smart Bus Hub ...
Страница 30: ...Document 101 0204 30 10 21 2011 Bill Dispenser ...
Страница 31: ...Document 101 0204 31 10 21 2011 Stacker Interface ...
Страница 35: ...Document 101 0204 35 10 21 2011 ...