Customer Control Board Connections

T


A

U

D

IO 
M

A

T

R

IX

M

IC

R

OP

H

ON

E

 S

H

IE

L

D

 -

 7

M

IC

R

OP

H

ON

E

 P

OS

IT

IV

E

 (

+

) -

 6

M

IC

R

OP

H

ON

E

 N

E

GA

T

IV

E

 (

-)

 -

 5

T

E

L

L

E

R

 C

A

L

L

 P

OS

IT

IV

E

 (

+

) -

 4

T

E

L

L

E

R

 C

A

L

L

 N

E

GA

T

IV

E

 (

-)

 -

 3

S

P

E

A

K

E

R

 P

OS

IT

IV

E

 (

+

) -

 2

S

P

E

A

K

E

R

 N

E

GA

T

IV

E

 (

-)

 -

 1

J

3

J

2

J

4

J

4

 IN

P

U

T

S

D

OOR

 A

U

T

O-
C

L

O

S

E

 -

 1

C

OM

M

ON

 -

 2

S

WI
T

C

H

E

S

S

WI
T

C

H

 1

S

WI
T

C

H

 2

S

WI
T

C

H

 3

J

1

3

M

IC

R

OP

H

O

N

E

C

ON

N

E

C

T

IO

N

J

1

2

 -

 S

P

E

A

K

E

R

C

ON

N

E

C

T

IO

N

J

8

 -

 R

J

4

5

IN

T

E

R

C

ON

N

E

C

T

J

7

 OU
T

P

U

T

S

N

OT

 U

S

E

D

 -

 1

P

R

E

S

S

U

R

E

 -

 2

D

OOR

 C

L

OS

E

 -

 3

N

OT

 U

S

E

D

 -

 4

H

OT

, B

L

OWE

R

 M

O

T

O

R

S

 -

 5

H

OT

, D

OOR

 M

O

T

O

R

 -

 6

N

OT

 U

S

E

D

 -

 7

V

A

C

U

U

M

 -

 8

D

OOR

 OP
E

N

 -

 9

P

OWE

R

 IN

P

U

T

2

4

 V

A

C

C

E

N

T

E

R

 T

A

P

2

4

 V

A

C

J

3

 IN

P

U

T

S

D

OOR

 S

A

F

E

T

Y

 (

N

C

) -

 1

C

OM

M

ON

 -

 2

T

E

L

L

E

R

 C

A

L

L

 (

N

O

) -

 3

C

OM

M

ON

 -

 4

C

U

S

T

OM

E

R

 S

E

N

D

 (

N

O

) -

 5

C

OM

M

ON

 -

 6

A

U

D

IO

RY4

J15

J11

J6

RY6

J7

RY2

RY1

J4

J2

C

1

J8

RY3

J13

B

R

1

J3

J12

JP1

C9

4

6

4

1

A

C

 -

 C

T

 - 

AC

OF
F

5

6

2

3

Inpu

ts

 3-

12

J

Pin 

- C

o

m

m

on
 for 
relay

s

 3 

and 

4

J9

J10

BR3

C15

TVS1

TVS10

J14

C

3

C14

B

R

2

TVS9

L1

C

17

RY5

C2

C5

TVS8

D9

C

4

Lane Stat

Teller Send

Carrier Present

Teller Recall

Door Open

Door Closed

Link

Door Safety

Night lock

Remote Carrier

Spare

(Option)

Air Flow

T/R Call

Vid. Power

Send

Spare/Teller

Auto Close

Carrier

 Recall

Vacuum

Outputs

Pressure

Closing

Opening

O

u

tp

u

ts

M

u

te

S

w

2

S

w

1

S

w

3

D

at

a R

ec

.

 Mi
c

In

p

u

ts

T

el

le

r

C

al

l

In

p

u

ts

In

p

u

ts

Power

F

ir

m

w

ar

e V

ersi
on

E

0

8

7

3

-C

E

0

8

7

3

-T

1

2

3

9

7

8

S

W
4

JP3

S

W
3

 - 

O

=

 T

e

ller 
Boar

d

S

W

- O

pt

iona

l run 

m

ode

S

W
4

 - 

C

a

rri

er

 R

ec
al

l

S

W
1

 - 

C

arr
ier 
T

im

Set

D8

D7

J

2

 IN

P

U

T

S

D

OOR

 OP
E

N

 S

WI
T

C

H

 (

N

O

) -

 1

C

OM

M

ON

 -

 2

D

OOR

 C

L

OS

E

 S

WI
T

C

H

 (

N

O

) -

 3

C

OM

M

ON

 -

 4

J

1

4

 OU
T

P

U

T

S

1

 -

 1

2

V

D

C

 +

2

 -

 1

2

V

D

C

 -

Содержание HA-1000

Страница 1: ...3143 Production Drive Fairfield Ohio 45014 513 874 3733 Model HA 1000 with I O controls Installation and Service Manual ...

Страница 2: ...conductor cable E0680 connected between the customer unit and audio matrix Preoperational settings and inspections The I O control board requires jumpers and switches to be properly set before operation See Section below All Micro Switches should be inspected for proper adjustment and operation by manually moving the door and safety bar before operating unit Switches should be set to allow for var...

Страница 3: ...cuum turbines If SW3 is turned on before SW1 the unit will enter Door Test Mode which allows send and teller call buttons to operate the customer door motor open and closed SW2 Switch 2 Turbine Mode Off is normal setting with single stage turbine On is normal setting with multi blower turbine systems SW3 Switch 3 Unit Selection Off is normal setting for board mounted in customer unit Standard swit...

Страница 4: ...d category 5 CAT5 cable Hamilton part number E0889 and terminated with male RJ 45 connectors on both ends The connectors should be wired in the straight through design as shown below on both ends There are commercially available testers that can be used to verify correct connector installation and function Wire Pin Teller Connections White Orange 1 Spare Orange 2 Teller Nigh Lock White Green 3 Tel...

Страница 5: ...ide use of the lane If there is a video monitor connected to the control circuit using Hamilton cable E10036 the night lock function will also turn the video monitor off for this lane Note if multiple lanes are installed each lane will have its own separate night lock switch Night lock switch located under recall button The night lock switch is shown pushed to the back which is the normal run posi...

Страница 6: ...E 5517 VIDEO UNIT OR E0873 C I O CONTROL BOARD OPERATION VIDEO POWER WILL BE CONTROLLED WITH THE PNEUMATIC UNITS NIGHTLOCK SWITCH WHEN THE UNIT IS IN NORMAL OPERATING MODE THE 5517 VIDEO UNITS MONITOR SHOULD BE SUPPLIED 12VDC POWER THROUGH THE SWITCHED TERMINALS ON THE E0883 RELAY BOARD SWITCHING TO NIGHTLOCK MODE WILL AUTOMATICALLY REMOVE THE 12VDC FROM THE SWITCHED TERMINALS ON THE E0883 RELAY B...

Страница 7: ... Send or Teller Recall button until carrier arrives in the teller unit Releasing button stores the time for this cycle Note For systems with carrier arrival switches at both ends when the carrier arrives at the teller unit and activates the carrier arrival switch the blowers will automatically turn off 5 Turn SW1 to the OFF position to store the cycle time for both directions Note For systems with...

Страница 8: ...ocedure for blower run time with CM2 Motorized Teller Unit 1 Restore default times as described above 2 Before beginning the carrier must be in customer unit with customer door open 3 Turn SW1 to the ON position LED indicator will light 4 Push and hold the Customer Send button until carrier arrives in the teller unit The carrier will activate the carrier arrival switch and the blowers will automat...

Страница 9: ...5 COMMON 6 AUDIO RY4 J15 J11 J6 RY6 J7 RY2 RY1 J4 J2 C1 J8 RY3 J13 BR1 J3 J12 JP1 C9 4 6 4 1 AC CT AC OFF 5 6 2 3 Inputs 3 12 J7 Pin 6 Common for relays 3 and 4 J9 J10 BR3 C15 TVS1 TVS10 J14 C3 C14 BR2 TVS9 L1 C17 RY5 C2 C5 TVS8 D9 C4 Lane Stat Teller Send Carrier Present Teller Recall Door Open Door Closed Link Door Safety Night lock Remote Carrier Spare Option Air Flow T R Call Vid Power Send Sp...

Страница 10: ... COMMON 8 NIGHTLOCK NO 9 COMMON 10 RY4 J15 J6 J7 RY2 RY1 J2 C1 J8 RY3 BR1 J3 JP1 C9 4 6 AC CT AC OFF Inputs 3 12 J7 Pin 6 Common for relays 3 and 4 J10 C15 TVS1 TVS10 C3 C14 BR2 TVS9 C2 C5 TVS8 C4 Lane Stat Teller Send Carrier Present Teller Recall Door Open Door Closed Link Door Safety Night lock Remote Carrier Spare Option Air Flow T R Call Vid Power Send Spare Teller Auto Close Carrier Recall V...

Страница 11: ...customer unit The control board can also be set up not to mute the customer microphone during blower operation for systems that are not affected by the blowers 1 Recall carrier to customer unit Press SW4 Recall located on control board 2 Press and hold SW4 and press the teller call button on customer unit The output LED for microphone mute will flash One flash the microphone is set to mute Two fla...

Страница 12: ... When this LED is on the airflow relay should be energized When this relay is energized the 120VAC power and neutral are disconnected from the pressure motor and the 24VAC power and neutral are connected The airflow operation will be automatically interrupted if the tube system is activated The airflow function can be turned on or off depending on the weather and need 1 Recall the carrier to the c...

Страница 13: ...stops the door as well as tripping the limit switches 4 Turn SW1 OFF and SW3 OFF for customer or ON for teller for normal operation Blower Run Test 1 Test is performed on terminal that turbines are controlled from This could be on either customer or teller station on a two board system 2 Recall carrier to station that has turbines connected so that door will open 3 Hold SW4 while switching SW1 ON ...

Страница 14: ... RY_T9A Vacuum Pressure 24VAC POWER MICROPHONE SPEAKER CABLE CONNECTIONS MATRIX AUDIO J5 1 7 4 3 6 2 5 SHLD MC TC SP SP MC TC DEFAULT SETTING ON MULTI MOTOR OFF SINGLE MOTOR ON TIMING MODE OFF RUN MODE ON TELLER OFF CUSTOMER NEUTRAL 60HZ 120VAC Date Drawing Number Rev 1 Rev 2 MODEL HA 1000 CUSTOMER UNIT ELECTRICAL DIAGRAM WITH I O CONTROL E0873 1 22 08 99 977 MC MC Off SHLD MC TC SP SP SP SW2 SW1 ...

Страница 15: ...Model HA 1000 with I O controls Installation and Service Manual ...