Troubleshooting
Problem Description
Possible Cause
Solution
• Control does not regenerate automatically
but does regenerate when [REGEN] button is
depressed
If water flow display is not operative, refer to
item 5 (“No water flow display when water is
flowing”) in this table
Refer to item 5 (“No water flow display when
water is flowing”) in this table
Incorrect hardness and capacity settings
Set new control values—Refer to programming
section
Defective circuit board
Replace control
• Run out of soft water between regenerations
Improper regeneration
Repeat regeneration making certain correct salt
dosage is used
Fouled resin bed
Use resin cleaner
Incorrect salt setting
Set salt setting to proper level—refer to the
programming section
Incorrect hardness or capacity settings
Set to correct values—refer to the programming
section
Water hardness has increased
Set to new value—refer to the programming
section
Restricted meter turbine rotation due to foreign
material in meter housing
Remove meter housing, free up turbine, and flush
with clean water. Turbine should spin freely—if not
replace meter
Water usage below 1/5 gallon per minute
Repair leaky plumbing and/or fixtures
Brine draw value from table 4 is incorrect
Set correct brine draw value
Incorrect salt type, or use of grid plate (salt shelf) Do not use block salt or grid plate (salt shelf) in
brine tank
• Control does not draw brine
Low water pressure
Increase water pressure (20 psi at conditioner)
Restricted drain line
Remove obstruction
Injector or injector screen is plugged
Clean injector and screen—refer to the “Cleaning
the Injector / Injector Screen” section
Injector defective
Replace injector and cap
Valve disc 3 and/or 5 not closed
Manually operate cam gear to flush out foreign
matter holding disc open. Replace if needed
Air check valve prematurely closed
Briefly put control into brine refill status. Refer
to the “Manual Regeneration” section. Repair air
check valve if needed
• Brine tank overflow
Brine valve disc 1 held open
Manually operate cam gear to flush out foreign
matter holding disc open
Valve disc 2 not closed during brine draw,
causing brine refill
Manually operate cam gear to flush out foreign
matter holding disc open
Air leak in brine line to air check
Check all connections in brine line for leaks
Salt setting too high
Set in new values—refer to programming section
• Intermittent or irregular brine draw
Low water pressure
Increase water pressure (20 psi at conditioner)
Defective injector
Replace both injector and injector cap
• No conditioned water after regeneration
Unit did not regenerate
Check for power
No salt in brine tank
Add salt to brine tank
Plugged injector
Remove injector and flush it and injector screen
Air check valve closed prematurely
Put control momentarily into REFILL to free air
check—replace or repair air check as needed
Incorrect salt type or use of grid plate (salt shelf)
in brine tank
Do not use block salt or grid plate (salt shelf) in
brine tank
Table 10:(Contiuned)
Troubleshooting procedures for most common
Содержание SA-HB-40-DB-CERT
Страница 1: ...Models SA HB 40 DB CERT SA HB 48 DB CERT Water Softener Made with Pride in the USA DuraResin Blend...
Страница 18: ...18 Hamilton Beach Owner s Manual Flow Diagrams Flow Diagrams Figure 20 Figure 21 Figure 22 Figure 23...
Страница 19: ...Hamilton Beach Owner s Manual 19 Flow Diagrams Figure 24 Figure 25 Figure 26...
Страница 20: ...20 Hamilton Beach Owner s Manual Control Valve Diagram Control Valve Diagram...
Страница 27: ...Hamilton Beach Owner s Manual 27 Notes...
Страница 28: ...28 Hamilton Beach Owner s Manual Notes...
Страница 29: ...Hamilton Beach Owner s Manual 29 Notes...
Страница 30: ...30 Hamilton Beach Owner s Manual Notes...
Страница 31: ...Hamilton Beach Owner s Manual 31 Notes...