12 | Hamilton Beach Owner’s Manual
Hamilton Beach Owner’s Manual | 13
Programming Guide
Level I Programming
Parameters
P1
Time of day
P2
Time of regeneration
P3
Water hardness (grains per gallon—gpg)
P4
Salt usage per regeneration (lbs)
P5
System capacity (Kg)
Table 3:
Level I programming parameters overview.
Default settings for models:
SA-HB-40-DB-CERT (40DB)
SA-HB-48-DB-CERT (48DB)
(Ultra-high efficiency settings)
Setting
Description
40DB
48DB
P1
Time of day
Set to current time of day
P2
Time of regeneration
2 a.m.
2 a.m.
P3
Water hardness
Set in field
Set in field
P4*
Salt usage
3.0 lbs
3.6 lbs
P5
System capacity
14.1 Kg
15.2 Kg
Table 4:
Level I programming default settings.
* Default settings are representative of ultra-high efficiency.
Level I Settings are identified as those that have an LED
indicator on the front panel. The green indicator illuminates
next to the name of the active control setting. (See Figure 19.)
Pressing the down arrow [
$
] button displays the Level I settings
in order. By continuing to press the down arrow [
$
] button, the
settings start over beginning with the time of day. Pressing the
up arrow [
#
] button displays the settings in reverse order.
Level I Programming
Parameters
P1
Time of Day AM or PM
Ranges
: 1:00 to 12:59 or 00:00 to 23:59
Minimum Increments
: 1 Min.
Units of Measure
: Hours & Minutes
Range
: Depends on the value selected for P13
P2
Time of Regeneration
Ranges
: 1:00 to 12:59 a.m. or p.m, 00:00 to 23:59
Minimum Increments
: 1 Min.
Units of Measure
: Hours & Minutes
Range
: Depends on the value selected for P13
P3
Water Hardness Setting
Range
: 3 to 250 (grains per gallon) gpg / 30 to 2500
(milligrams per liter) Mg/L
Minimum Increments
: 1 for (gpg), 10 for (Mg/L)
Units of Measure
: Grains per gallon (gpg) / Milligram
per liter (Mg/L)
Range
: Unit of measure depends on the value selected
for P12. Test water hardness (compensated hardness)
and enter that value.
P4
Salt Amount (maximum)
Ranges
: 0.5 to 99.5 (pounds) or 0.1 to 25.5
(kilograms)
Minimum Increments
: 0.5 (pounds) or 0.1
(kilograms)
Units of Measure
: Pounds or Kilograms
Range
: Unit of measure and default depends on value
selected for P12.
P5
System Capacity
Ranges
: 0.1 to 140 Kgr or 0.01 to 14.0 Kgr
Minimum Increments
: 0.1 Kgr or 0.01 Kgr
Units of Measure
: Kgr or Kilograms
Range
: Depends on value selected for P12
Figure 19:
Control valve interface.
Содержание SA-HB-40-DB-CERT
Страница 1: ...Models SA HB 40 DB CERT SA HB 48 DB CERT Water Softener Made with Pride in the USA DuraResin Blend...
Страница 18: ...18 Hamilton Beach Owner s Manual Flow Diagrams Flow Diagrams Figure 20 Figure 21 Figure 22 Figure 23...
Страница 19: ...Hamilton Beach Owner s Manual 19 Flow Diagrams Figure 24 Figure 25 Figure 26...
Страница 20: ...20 Hamilton Beach Owner s Manual Control Valve Diagram Control Valve Diagram...
Страница 27: ...Hamilton Beach Owner s Manual 27 Notes...
Страница 28: ...28 Hamilton Beach Owner s Manual Notes...
Страница 29: ...Hamilton Beach Owner s Manual 29 Notes...
Страница 30: ...30 Hamilton Beach Owner s Manual Notes...
Страница 31: ...Hamilton Beach Owner s Manual 31 Notes...