TECHNICAL DATA SHEET
JOSENG-FRM-RIC-4.32 Rev. D
HAMILTON BEACH / PROCTOR-SILEX, INC.
4421 WATERFRONT DRIVE GLEN ALLEN, VA 23060
ISSUE CODE
DRAWN BY:
ENG. IN CHG.
DATE:
APPROVED BY:
SP
6/21/14
DOC4905
INITIAL USE:
PICT. REF.
SHEET
DRAWING NO.
REV.
10 /
15
520008200
18. Adjust the unit regulator to 30 psi by pulling out the knob and rotating until the needle
indicates 30 psi. Push the regulator knob in until it “clicks” to prevent tampering.
19. On the control panel, verify the spirits valve is rotated to Dispense